Advertisement

LABCYTE INC.
Echo® 650 Series Liquid Handler
(Models: 650, 655, 650T, 655T)
SITE PREP GUIDE
Server Version 3.1 | FEBRUARY 2019
This guide provides site preparation information for the Echo® 650 Series Liquid Handler. This includes models 650, 655, 650T
and 655T. The topics below describe the site preparation requirements and instrument specifications for the Echo Liquid
Handlers.
l
l
l
l
l
l
l
l
l
Junair Compressor (Optional and sold separately by Labcyte)
l
Vacuum Pump (Optional and sold separately by Labcyte)
l
Client Pc (Sold separately by Labcyte)
l
© 2019 LABCYTE INC. All rights reserved.
|
SITE PREP GUIDE
Echo® 650 Series Liquid Handler
QSG-2019-1
FEB 2019

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Echo 655 and is the answer not in the manual?

Questions and answers

Summarization of Contents

Site Requirements
Operating environment
Specifies temperature and relative humidity requirements for the Echo Liquid Handler and chiller.
AC Power (2 options)
Details the voltage, frequency, and amperage requirements for the AC power supply.
Compressed air source
Defines the specifications for the clean, filtered, oil-free, and dry compressed air supply.
User Supplied Equipment Requirements
Hardware
Specifies the compressed air and vacuum fittings needed for tubing connections.
Client PC
Lists the minimum hardware and OS requirements for the client PC.
Communication Requirements
Server connection
Specifies the Echo Liquid Handling Platform server version.
Network connection
Details the network connection speed (10/100/1000 BaseT).
Network protocol
States the required network protocol (TCP/IP).
User account
Defines the necessity of an administrator account for service access.
Accommodating Your Echo Liquid Handler
The Echo Liquid Handler Dimensions
Provides the physical width, depth, and height of the instrument.
Echo Liquid Handler working envelope (minimal installation requirements)
Specifies clearances needed around the instrument for operation and service.
SMC Chiller Dimensions
Details the required space for the SMC chiller.
Echo Client PC
Notes additional space required for the client PC and peripherals.
What You Will Be Receiving
Shipping Dimensions
Details the crate size and weight for shipping the instrument.
Echo Liquid Handler Components
Lists all the included parts and accessories with the Echo Liquid Handler.
Chiller
Power Supply
Describes the chiller's auto-switching power supply capabilities.
Temperature Control
Explains how the chiller controls fluid temperature.
Ambient Operating Conditions
Specifies the temperature and humidity range for chiller operation.
Vacuum Pump (Optional and sold separately by Labcyte)
House supply
Specifies requirements for using a house vacuum source.
Standalone vacuum with surge tank (10 L)
Details specifications for a standalone vacuum pump system.
Vacuubrand MZ 2S-NT vacuum system specifications
Lists detailed technical specifications for the Vacuubrand MZ 2S-NT pump.
Client PC Specifications
Operating system
Specifies the required operating system for the client PC.
CPU
Details the minimum processor requirements for the client PC.
Memory
Specifies the minimum RAM required for the client PC.
Hard drive storage
States the minimum hard drive storage needed for the client PC.
Video Resolution
Defines the minimum video resolution for the client PC display.
Ethernet
Specifies the required Ethernet connection type and speed.
Included Accessories
Lists accessories included with the Dell OptiPlex XE2 client PC.
Software specifications
Notes optional Echo software applications and version requirements.

Table of Contents

Save PDF