Available languages

INSTALLATION
WARNING: Review and un-
derstand the warnings in the
Safety Information section, page
2. They are needed to safely op-
erate this heater. Follow all local
codes when using this heater.
WARNING: Test all gas piping
and connections for leaks after
installation or servicing. Never
use an open flame to check for
a leak. Apply a mixture of liquid
soap and water to all joints.
Bubbles forming show a leak.
Correct all leaks at once.
1. Provide propane supply system (see Propane
Supply, page 4).
2. Connect POL fitting on hose/regulator as-
sembly to propane tank(s). Turn POL fitting
counterclockwise into threads on tank. Tighten
firmly using 7/8" wrench. IMPORTANT: Posi-
tion regulator so that hose leaving the regulator
is in a horizontal position (see Figure 6). This
places the regulator vent in the proper position
to protect it from the weather.
Propane
Supply Valve
Propane
Tank
Figure 6 - Regulator Position
Figure 7 - Hose and Inlet Connector
104787-01D
Regulator
Hose
POL Fitting
www.desatech.com