ASSEMBLY

1. Remove screw from top of fan guard. Discard
screw.
2. Insert nut clip (provided with handle) with
flat side facing up through slot in top of shell.
Align holes in nut clip with screw hole behind
slot in top of shell. (see Figure 4).
3. Place handle over hole and clip. Insert two
screws (provided with handle) through handle
and tighten into shell. Make sure rear screw
goes through shell and into fan guard. Tighten
screws firmly.
Figure 3 - Removing Screw from Top of
Fan Guard
Slot
Flat Side
Facing Up
Figure 4 - Installing Nut Clip
Nut Clip
Figure 5 - Attaching Handle
4
Propane gas and propane tank(s) are to be fur-
nished by the user.
Use this heater only with a propane vapor
withdrawal supply system. See Chapter 5 of the
Standard for Storage and Handling of Liquefied
Petroleum Gas, ANSI/NFPA 58 and/or CAN/CGA
B149.2. Your local library or fire department will
have this booklet.
The amount of propane gas ready for use from
propane tanks varies. Two factors decide this
amount:
1. The amount of propane gas in tank(s)
Remove
2. The temperature of tank(s)
Screw
This heater is designed to operate with a minimum
20 lb (9 kg) propane tank. You may need two or
more tanks or one larger tank in colder weather.
Use a 100 lb (45 kg) tank for longer operation
or in very cold weather. Less gas is vaporized at
lower temperatures. Your local propane gas dealer
will help you select the proper supply system. The
minimum surrounding air temperature rating for
each heater is -20° F (-29° C).
Nut Clip
Smaller tanks can be used for limited run times
Shell
but it is recommended to use larger tanks for
optimum performance.
Screws
Handle
Rear of
Heater
www.desatech.com

PROPANE SUPPLY

Average Temperature
At Tank
Above 0° F (-18° C)
Below 0° F (-18° C)
VENTILATION
WARNING: Provide at least
a 1 ft
(0.09 m
) opening of fresh,
2
2
outside air while running heater. If
proper fresh, outside air ventilation
is not provided, carbon monoxide
poisoning can occur. Provide
proper fresh, outside air ventila-
tion before running heater.
Number Of Tanks
100 lb (45 kg)
1
2
104787-01D