PIPETBOY acu 2 Operating instructions
466079_V13

Advertisement

loading
Need help?

Need help?

Do you have a question about the PIPETGIRL and is the answer not in the manual?

Questions and answers

Summary of Contents for Integra PIPETGIRL

  • Page 1 PIPETBOY acu 2 Operating instructions 466079_V13...
  • Page 2 Declaration of conformity INTEGRA Biosciences AG – 7205 Zizers, Switzerland declares on its own responsibility that the devices Description Models PIPETBOY acu 2 155000, 155015, 155016, 155017, 155018, 155019 PIPETGIRL 155021 comply with: EU Directives (DoW: Date of Withdrawal) Before DoW...
  • Page 3: Table Of Contents

    PIPETBOY acu 2 - Operating instructions V13 Table of Contents 1 Introduction ........................ 4 2 Description of the device .................... 5 3 Installation ........................6 4 Operation ........................7 5 Maintenance......................10 6 Technical Data ......................11 7 Accessories ......................12 Imprint ©...
  • Page 4: Introduction

    PIPETBOY acu 2. Safety notes 1) Do not use or charge PIPETBOY acu 2 in an atmosphere with danger of explosion. Also, do not pipette highly flammable liquids such as acetone or ether. 2) When handling dangerous substances, comply with the material safety data sheet (MSDS) and with all safety guidelines such as the use of protective clothing and safety goggles.
  • Page 5: Description Of The Device

    PIPETBOY acu 2 - Operating instructions V13 Description of the device Description of the device Scope of delivery • PIPETBOY acu 2 / PIPETGIRL device • 1 rechargeable Li-ion battery • Mains adapter • Wall mount • Hydrophobic sterile filter 0.45 µm (spare) •...
  • Page 6: Installation

    Installation Charging the battery A full charge takes 3.5 hours. Before the first use, PIPETBOY acu 2 should be charged until the battery charge indicator (4) turns green, showing that the battery is full. When the battery charge indicator (4) starts flashing red, PIPETBOY acu 2 can be used for around 100 pipetting cycles before shutting down.
  • Page 7: Operation

    “to deliver” (TD) pipettes that are not of the “blow-out” type (blow-out pipettes have two thin rings or a frosted band around the neck). PIPETBOY acu 2 is featured with a “TURBO” mode. Plug the mains adapter cable into the pipette controller and turn the thumb wheel completely to the right for maximal speed.
  • Page 8 PIPETBOY acu 2 – Operating instructions V13 Operation INTEGRA Biosciences AG...
  • Page 9 PIPETBOY acu 2 – Operating instructions V13 Operation www.integra-biosciences.com...
  • Page 10: Maintenance

    PIPETBOY acu 2: liquid should not leak out of a filled pipette before the dispensing button is pressed. Cleaning and servicing PIPETBOY acu 2 can be cleaned with a cloth moistened with soapy water or with a 70 % ethanol. Disassembly of the nose piece: Unscrew the nose piece (7) from the handle by turning it counter clockwise.
  • Page 11: Technical Data

    Storage: -10–50°C, max. 95% RH Chemical compatibility The table below lists PIPETBOY acu 2 parts that come into contact with the aspirated liquid or its aerosols and vapors, and rates the compatibility of these parts to a few of the chemicals commonly used in laboratories.
  • Page 12: Accessories

    C = Critical: not recommended, suitability to be determined by test. Accessories Accessories Part No. Stand for for a well organized work area, to park PIPETBOY acu 2 with 155065 PIPETBOY inserted pipette Wall mount for holding PIPETBOY acu 2 on the wall...
  • Page 13 PIPETBOY acu 2 classic and transparent; 155025 (nose piece) with filter 0.45 µm, unsterile complete (7) classic (grey) for PIPETBOY acu 2 green, red, blue, purple 155070 and PIPETGIRL; with filter 0.45 µm, unsterile Sterile module turquoise, for PIPETBOY acu 2 classic and transparent...