Front Panel Features
Outlet Bank Power LED Icons
Indicates the status of the correspon-
ding rear panel outlets. The LED will
be lit when the outlets are turned ON.
They will flash during the startup and
shutdown process.
BANK 1
BANK 2
LINEAR
HIGH
FILTER
CURRENT
Power Button
Press and hold for one second to turn
Bank 1 and Bank 2 outlets ON or OFF.
Back Panel Features
Outlet Bank 2
Circuit Breaker
Four switched, High Current out-
Automatically opens
lets controlled by the front panel
when the current load
Power Button.
is greater than 15
Amps. Push to reset.
The High Current outlets provide
power from a low impedance
noise filtration circuit that does not
limit the current to your equip-
ment. Its output is noise isolated
from all of the other outlets.
GROUND
15 AMP
LUG
MAIN POWER
CIRCUIT
SUBWOOFER
120 VAC/15A
BREAKER
Main Power
Must be plugged into a properly
wired & grounded 3-wire outlet
2
Digital Voltmeter
Digital LED voltmeter indicates the incoming line
voltage. If line voltage drops below 90VAC, or if the
line voltage exceeds 142VAC, the display will turn
off and the "unsafe voltage" indicator will flash
indicating an unsafe voltage condition.
Front Panel Lights:
2 switchable convenience lights to view
your media and home theater system
when it's dark.
Outlet Bank 1
Four switched linear filtered outlets controlled by
the front panel Power Button.
Linear (LiFT) EMI/RFI noise filtration is provided
by a two stage tapped Pi filter circuit which also
provides noise isolation from all four outlets in
Bank 2.
RECEIVER
AUX / VCR
AMPLIFIER
BANK 2 - SWITCHED - HIGH CURRENT
Ground Lug
Provides a common grounding
point for equipment with separate
ground leads.
Unsafe Voltage Indicator
Located in the voltmeter, the Unsafe Voltage
Indicator is normally off. Flashes red to
indicate that the incoming line voltage is
unsafe and the unit has disconnected the
power to protect your equipment.
M4300-PM
VOLTS
Light/Meter/Front panel LED dimmer:
For lights: Quick push for varying levels of
brightness. For Meter/Front panel LED: Push
and hold for varying levels of brightness.
LAN Protection circuits for 10/100 baseT
Ethernet lines. Incoming LAN line MUST be
plugged into the LINE jack. Patch cord to the
equipment MUST be plugged into the EQUIP
jacks. 8 wire protection, 50V clamping.
DVR
HD CABLE / SAT
CD / DVP
BANK 1 - SWITCHED - LINEAR FILTRATION
Note to CATV Installers:
This reminder is provided to call attention to Article 820-40 of the NEC. That article provides
specific guidelines for proper grounding.It specifies that the cable ground shall be connected
to the grounding system of the building and as close to the point of entry as practical.
Gaming Outlet:
MAX® 4300-PM features a
convenience outlet located on
the front panel. Perfect for
gaming systems and other elec-
tronics.
Universal TV Coaxial Jacks
2 pairs of bidirectional protection
circuits, optimized for satellite,
cable, and antenna TV signal lines.
LAN
LAN
LAN
LAN
OUT
IN
TEL
TEL
HDTV / MONITOR
Phone Jacks
Protection circuits standard telephone or
pay-per-view lines. Phone circuit is auto-
resetting. Incoming phone cords MUST be
plugged into the LINE jack. Patch cords to
the equipment (satellite receiver, digital video
recorder, telephone, etc.) MUST be plugged
into the EQUIP jacks.
USB Charger:
MAX® 4300-PM features a
front panel convenience
charger for mp3 players, cell
phones, and other small elec-
tronics.
1
2
IN
IN
UNIVERSAL COAX PROTECTION
1
2
OUT
OUT