Panamax MAX 5510 ACRegenerator Owner's Manual

Panamax MAX 5510 ACRegenerator Owner's Manual

Panamax corp. owner's manual power supply max 5510

Advertisement

Quick Links

MAX
5510 ACRegenerator
®
Owner's Manual
1690 Corporate Circle, Petaluma, CA 94954 • www.panamax.com

Advertisement

Table of Contents
loading

Summary of Contents for Panamax MAX 5510 ACRegenerator

  • Page 1 5510 ACRegenerator ™ ® Owner’s Manual 1690 Corporate Circle, Petaluma, CA 94954 • www.panamax.com...
  • Page 2 MAX 5510. This model has been specifically ACRegenerator, Firewall for Noise, SurgeGate Plus, Protect or Disconnect and SignalPerfect are trademarks of PANAMAX. SIDACtor is a registered US trademark of Teccor Electronics, Inc. TiVo is a trademark of TiVo, Inc.
  • Page 3: Table Of Contents

    3 - Coax Cables for Satellite TV, Cable TV and/or Antennas Please verify that you have received all these items. If not, contact Panamax. USA & Canada (800) 472-5555 • (707) 283-5900 • Fax (707) 283-5901 High-Current Outlet Bank...8 Voltage Sense Triggers...8 Circuit Breakers...8...
  • Page 4: Introduction

    This creates a balanced voltage waveform (+60V Line-Ground & - 60V Neutral-Ground, 180 degrees out-of-phase), which still provides 120VAC to your equipment. 1690 Corporate Circle, Petaluma, CA 94954 • www.panamax.com The MAX 5510 allows you to switch between ®...
  • Page 5: Connection Diagram

    CONNECTION DIAGRAM Tri-Power Filtration System USA & Canada (800) 472-5555 • (707) 283-5900 • Fax (707) 283-5901...
  • Page 6: Feature Overview

    Low-Current analog for equipment components such with separate as pre-amplifiers, ground leads receivers, VCR’s and tape decks. 1690 Corporate Circle, Petaluma, CA 94954 • www.panamax.com AC Regeneration LED Indicators: Ammeter: Control and LED Status indicator lights Backlit analog meter Indicators:...
  • Page 7: Feature Details

    MAX 2. USE ONLY A 12V DC, 5W-HALOGEN BAYONET BASE, ANSI T-3 REPLACEMENT BULB. Use USHIO JC12V- 5W/BA9S or equivalent. A higher rated bulb will overload the lamp power supply and cause damage not covered by the warranty.
  • Page 8: Diagnostic Lights

    AC Regeneration Control : Pushbutton switch used for selecting the power supply mode for the digital source com- ponents connected to the Isolation Transformer Outlet Bank. One of the adjacent LEDs for Isolated Power or Balanced Power will illuminate to indicate the active switch position.
  • Page 9: Filtered Outlet Banks 1 & 2

    FEATURE DETAILS Filtered Outlet Banks 1 & 2 Four outlets (two banks / two outlets per bank) are fed through separate "Balanced, Double L" noise filtration circuits. These circuits are designed to eliminate the noise contamination of the AC power that is most detrimental to the performance of analog or video components like stereo receivers, VCRs or televisions.
  • Page 10: High-Current Outlet Bank

    Traditional line conditioners impede this current draw, in effect, starving an amplifier and resulting in a flat, dead sound. The High-Current Outlet Bank provides clean, filtered power to amplifiers but has no current-limiting components to impede performance.
  • Page 11: Audio / Video Line Level Protection

    Power Cord The MAX 5510 comes equipped with a UL recognized, 10 foot, IEC320 power cord rated for 120V, 15-Amps, minimum 14 gauge wire and the cord secured to the enclosure with a cord retention bracket. The cord is not intended to be removed.
  • Page 12: Ac Surge Protection

    5510 provides protection against common problems on the AC power line. This includes spikes/surges and sus- ® tained overvoltages or undervoltages. Panamax’s exclusive Protect or Disconnect™ circuitry is designed to protect against spikes/surges while the SurgeGate Plus™ circuitry is for sustained over/under voltage protection.
  • Page 13: Technical Specifications

    Design and specifications subject to change without notice due to product improvement. CONTACTING PANAMAX For product and warranty information, dealer information, and other general information contact Customer Relations at: • Email: custrelations@panamax.com • www.panamax.com • Fax 707-283-5901 • 800-472-5555 or 707-283-5900, 7:30 a.m.- 5 p.m. PST USA &...
  • Page 14: Balanced Vs. Isolated Power

    (but to a much lesser degree than with grounded-neutral power), unless the impedances from L-G and N-G in the connect- ed equipment are equal. 1690 Corporate Circle, Petaluma, CA 94954 • www.panamax.com Balanced Power With "Balanced Power", the asymmetric, zero-volt N-G reference at the panel is replaced by a symmetric ground reference between line and neutral.
  • Page 15: Frequently Asked Questions

    1. Check to see if the bulb is burned-out. 2. If the bulb is good, if the unsafe voltage LED is OFF and the light control knob is turned on and the light is still not on, call Panamax Customer Service for help. ____ The halogen light on the Convenience Lamp is dead.