Summary of Contents for Panamax MAX 5410

  • Page 1 5410 Pro Series ® Owner’s Manual 1690 Corporate Circle, Petaluma, CA 94954 • www.panamax.com...
  • Page 2 PANAMAX, the Panamax logo and MAX are registered US trademarks of Panamax. Protect or Disconnect, SurgeGate Plus and SignalPerfect are trademarks of PANAMAX. © 2003 PANAMAX CORP. All Rights Reserved.
  • Page 3: Table Of Contents

    BEFORE YOU BEGIN Items included with the MAX ® LED Lamp Please verify that you have received all these items. If not, contact Panamax. USA & Canada (800) 472-5555 • (707) 283-5900 • Fax (707) 283-5901 Technical Specifications...11 Contacting Panamax...11 Frequently Asked Questions...12...
  • Page 4: Introduction

    10 second shutdown delay if these outlets are configured as Switched. 1690 Corporate Circle, Petaluma, CA 94954 • www.panamax.com High-Current Outlet Bank: The unique power requirements of current hungry components such as amplifiers and powered subwoofers are also addressed.
  • Page 5: Connection Diagram

    CONNECTION DIAGRAMS STEP 1 Typical AC Power, RS232 and 12V Trigger Connections AMPLIFIER CD PLAYER CIRCUIT BREAKER GROUND PROPERLY GROUNDED AC OUTLET AC INLET SUBWOOFER STEP 2 Basic Signal Line Connections DUAL LNB SATELLITE DISH CIRCUIT BREAKER GROUND HIGH CURRENT ALWAYS ON OUTLETS SWITCHED OUTLETS OUTLETS...
  • Page 6: Feature Overview

    This is the sec- ond trigger that will activate the MAX shutdown sequence. (See pushbutton on front panel). 1690 Corporate Circle, Petaluma, CA 94954 • www.panamax.com LED Indicators: Meter Light Dimmer: Status indicator lights for: Controls brightness • DC Voltage Trigger of the Voltmeter •...
  • Page 7: Feature Details

    FEATURE DETAILS Front Panel Pushbutton This button controls the “High-Current” and “Switched” outlets. TRIGGER SWITCHED GROUND OUTLETS Sequential Startup/Shutdown Complex audio/video systems may be susceptible to voltage transients generated inter- nally at start-up/shutdown if all of the equipment is powered on or off at the same time. This can cause speaker “thumps” which are not only annoying but can also damage the speakers.
  • Page 8: Voltmeter

    It is important to remember that power will be disconnected only in the event of an unsafe voltage condition. 1690 Corporate Circle, Petaluma, CA 94954 • www.panamax.com Green LED. When this light is ON, it indicates that the wall outlet is properly wired. When the light is OFF, Red LED.
  • Page 9: Filtered Outlet Banks

    FEATURE DETAILS POWER PROTECTION CIRCUITRY WALL OUTLET HIGH CURRENT OUTLETS Filtered Outlet Banks HIGH CURRENT OUTLETS SWITCHED OUTLETS ALWAYS ON OUTLETS Eight Outlets (4 banks / 2 outlets per bank) are fed through cascaded noise filtration circuits. These circuits are designed to RS232 CO eliminate AC contamination that is detrimental to the performance of audio or video components like stereo receivers, VCRs 12V TR...
  • Page 10: High-Current Outlet Bank

    GROUND of current to replenish its power supply capacitors. Traditional line conditioners impede this current draw, in effect, starving IEC320 INLET an amplifier and resulting in a flat, dead sound.
  • Page 11: Coaxial Line Protection

    (per applicable NEC/CEC code). A driven ground rod is not adequate. Panamax’s exclusive SignalPerfect™ Technology provides application-specific protection for your satellite and cable TV equipment. Two lines of protection are provided for each type. The satellite connections are for coaxial cables connected to a DBS (single or dual LNB) satellite dish.
  • Page 12: Ac Surge Protection

    5410’s Protect or Disconnect™ Circuitry will disconnect your equipment in order to protect it. The MAX 5410 will need to be repaired or replaced by Panamax if this occurs. (See Product Warranty). SurgeGate Plus™ Protection The MAX ®...
  • Page 13: Technical Specifications

    Design and specifications subject to change without notice due to product improvement. CONTACTING PANAMAX For product and warranty information, dealer information, and other general information contact Customer Relations at: • Email: custrelations@panamax.com • www.panamax.com • Fax 707-283-5901 • 800-472-5555 or 707-283-5900, 7:30 a.m.- 4:30 p.m. PST USA &...
  • Page 14: Frequently Asked Questions

    5410 power cable does not ® reach the wall outlet. Can I use an extension cord to make it reach? Yes, but you must use only Panamax extension cords to keep your warranty valid. Ask for part # GEC1410. (10 feet long) or #P12X10NEMA5-15.
  • Page 15: Max Pro-Series Rs-232 Command Specs

    1. OVERVIEW The Panamax Pro-Series product family has a RS232 interface that allows it to communicate with a wide variety of equipment. The purpose of this document is to outline the command set used to communicate with the Pro-Series (PS) products.