MAINTENANCE

Maintenance Schedule

Periodic maintenance and adjustment are necessary to keep the generator in good operating condition. Perform service and
inspection at intervals shown in Generator Maintenance Schedule (see Table 2).
Using a generator indoors CAN KILL YOU IN MINUTES.
Generator exhaust contains carbon monoxide. This is a poi-
son you cannot see or smell.
NEVER use inside a home
or garage, EVEN IF doors
and windows are open.
• Shut off engine before performing any maintenance. If
engine must be run, be sure area is well ventilated.
NOTICE
Maintenance, replacement, or repair of the emission
control devices and systems may be performed by any
non-road engine repair establishment or individual.
MAINTENANCE TASK
Inspect for/clean debris
Check engine oil level
Change engine oil
Check air filter
Clean air filter
Run engine
Clean/change spark plug
Clean fuel sediment cup
Clean spark arrestor
Clean cylinder cooling fins
Check/adjust valve clearance
Clean fuel tank and strainer
Check fuel line
TABLE 2. Generator Maintenance Schedule
* Perform at every indicated month or operating hour interval, whichever comes first.
** It is recommended that the generator is run for 15-30 minutes every three months to ensure the battery remains charged.
If the unit is stored for more than a year without running, a battery charger may required to recharge the generator battery.
† Clean more often when using generator in dusty areas.
‡ It is recommended that this maintenance task be performed by a service dealer.
HW5500/HW5500E/HW5500EL/HW5500L Portable Electrical Generator Owner's Manual
Only use OUTSIDE and far
away from windows, doors, and
vents.
First month or
Before each
20 hours of
use
X
X
X
Accidental starting of generator can cause severe injury or
death. Before performing maintenance, disconnect spark
plug cap from spark plug. Also disconnect both starting bat-
tery cables. Remove the negative (-) cable first to reduce the
risk of arcing.
Improper maintenance, or failure to correct a problem before
operation, can cause a malfunction in which you can be seri-
ously hurt or killed. Always follow inspection and mainte-
nance recommendations and schedules in this owner's
manual.
The maintenance schedule applies to normal operating con-
ditions. If you operate generator under severe conditions,
such as sustained high-load or high-temperature, or use it in
unusually wet or dusty conditions, consult your servicing
dealer for recommendations applicable to your individual
needs and use.
FREQUENCY
Every 3
months or 50
use
hours of use
X
X
X**
Every 2 years (replace if necessary)‡
NOTICE
*
Every 6
Every year or
months or 100
200 hours of
hours of use
X
X
X
www.honeywellgenerators.com
use
X
X
X
X
21