Mc-12 Set Parameter Notification By Id (Mc-12) - Lexicon MC-12 V3.0 - SERIAL COMMUNICATIONS PROTOCOL DEFINITION REV 1-5 Manual

Serial communications protocol definition software version 3.0
Table of Contents

Advertisement

Lexicon, Inc.
MC-12 Serial Communications Protocol
ParamId:
Data Type:
Max:
7.3.41.3 Data Validation
If ParamId exceeds the its maximum value, the MC-12 will ignore the command and transmit a
DC_NAK command with an error code DC_INVALID_PARAM_ID.
7.3.41.4 MC-12 Value String Response Packet
Application Header:
Command
Data Count
Application Data:
Data[0]
Data[1]
Data[2]
Data[3-23]
7.3.41.5 Data Description
Same as
Paragraph 7.3.37.2

7.3.42 MC-12 Set Parameter Notification by Id (MC-12)

Request to MC-12 to enable or disable transmission of the MC-12 parameter change notification for a given
parameter.
7.3.42.1 Command Packet Description
Application Header:
Command
Data Count
Application Data:
Data[0]
Data[1]
Data[2]
7.3.42.2 Data Description
ParamId:
Data Type:
Max:
Enable/Disable:
Data Type:
TRUE:
FALSE:
7.3.42.3 Data Validation
© 2003 Lexicon, Inc. All rights reserved.
Unsigned 16 bit integer.
Max Parameter Count as reported by the MC-12 Unit Configuration
Response Packet in 7.3.39.2
MC_RESP_PARAM_VALUE
24
ParamId (LSB)
ParamId (MSB)
ParamType
Value[0 -20]
MC_CMD_SET_PARAM_NOTIFICATION_BY_ID 0x3B
3
ParamId (LSB)
ParamId (MSB)
Enable/Disable
Unsigned 16 bit integer.
Max Parameter Count as reported by the MC-12 Unit Configuration
Response Packet in 7.3.39.2
Boolean
Enable transmission of parameter notification
Disable transmission of parameter notification
Printed on: 08/18/03
0x92
0x18
nn
nn
nn
nn nn
nn...
0x03
nn
nn
nn
42 of 94