Mounting Ring - Simrad ES38-10 - INSTALLATION REV H Installation Manual

38 khz split-beam transducer
Table of Contents

Advertisement

Simrad ES38-10

Mounting ring

Surface treatment:
1) Sand blast to SA 2.5
2) One coating of red ferric oxide primer
310
The self-lock threads (SL*) must be made in
accordance with Simrad procedure 842-202125.
Self-lock taps can be supplied by Simrad.
Note:
All measurements are in mm.
The drawing is not in scale.
40
30°
60°
M10 SL* (x6)
Ø0.2
CD017015G Page 1 of 2
871-203337 Rev.B
305176/A

Advertisement

Table of Contents
loading

This manual is also suitable for:

Es38-10

Table of Contents