EVCO S.p.A. EVSX815 | Installer manual ver. 1.3 | Code 144XS815E134 EVXS815 Split execution controller for temperature-controlled blast chillers (integrated into the unit) ENGLISH INSTALLER MANUAL ver. 1.3 CODE 144XS815E134 page 1 of 60...
Page 2
EVCO S.p.A. EVSX815 | Installer manual ver. 1.3 | Code 144XS815E134 Important Important Read this document thoroughly before installation and before use of the device and follow all recommendations; keep this document with the device for future consultation. The following symbols support reading of the document:...
EVCO S.p.A. EVSX815 | Installer manual ver. 1.3 | Code 144XS815E134 Index INTRODUCTION ........................... 5 Introduction ............................5 Summary table of the main features and the models available ..............6 DESCRIPTION ............................9 Description of the user interface ......................9 Description of the control module ......................
EVCO S.p.A. EVSX815 | Installer manual ver. 1.3 | Code 144XS815E134 INTRODUCTION Introduction EVXS815 is a digital controller studied to manage temperature-controlled blast chillers, which can be mechanically and aesthetically integrated into the unit. The controller is fitted with: clock...
EVCO S.p.A. EVSX815 | Installer manual ver. 1.3 | Code 144XS815E134 Summary table of the main features and the models available The following table illustrates the main features of the device and the models available. “ / “ indicates the feature can be set via a configuration parameter.
Page 7
EVCO S.p.A. EVSX815 | Installer manual ver. 1.3 | Code 144XS815E134 evaporator fan door heating elements/condenser fan 16 A cabinet light/needle probe heating/UV light Communication port EVXS815 serial port with MODBUS communication protocol • Other features EVXS815 clock • signal buzzer and alarm •...
Page 8
EVCO S.p.A. EVSX815 | Installer manual ver. 1.3 | Code 144XS815E134 For further information, see chapter 14 "TECHNICAL DATA"; for other models contact the Evco sales network. page 8 of 60...
EVCO S.p.A. EVSX815 | Installer manual ver. 1.3 | Code 144XS815E134 DESCRIPTION Description of the user interface The following drawing illustrates the aspect of the EVXS815 user interface. The following table illustrates the meaning of EVXS815 user interface parts. Part...
EVCO S.p.A. EVSX815 | Installer manual ver. 1.3 | Code 144XS815E134 Description of the control module The following drawing illustrates the aspect of the EVXS815 control module. The following table illustrates the meaning of EVXS815 control module parts. Part Meaning...
EVCO S.p.A. EVSX815 | Installer manual ver. 1.3 | Code 144XS815E134 DIMENSIONS AND INSTALLATION User interface dimensions The following drawing illustrates the EVXS815 user interface dimensions; these are expressed in mm (in). Control module dimensions The following drawing illustrates the EVXS815 control module dimensions; these are expressed in mm (in).
EVCO S.p.A. EVSX815 | Installer manual ver. 1.3 | Code 144XS815E134 User interface installation Back panel via M3 studs. Control module installation On flat surface, with spacers. Installation warnings make sure that the device work conditions (temperature of use, humidity, etc.) lie within the limits indicated;...
EVCO S.p.A. EVSX815 | Installer manual ver. 1.3 | Code 144XS815E134 ELECTRIC CONNECTION Electric connection The following drawing illustrates the EVXS815 electric connection. The utility managed by the K4 output, depends on parameter u1, as follows: door heating elements (u1 = 0, pre-defined setting) condenser fan (u1 = 1).
14 "TECHNICAL DATA" disconnect the device power supply before proceeding with any type of maintenance do not use this device as a safety device for repairs and information regarding the device, contact the EVCO sales network. page 14 of 60...
EVCO S.p.A. EVSX815 | Installer manual ver. 1.3 | Code 144XS815E134 USER INTERFACE Foreword The following operating status exist: the “off” status (the device is not powered) the “stand-by” status (the device is powered and is off) the “on” status (the device is powered, is on and is in stand-by for the start-up of an operating cycle) the “run”...
EVCO S.p.A. EVSX815 | Installer manual ver. 1.3 | Code 144XS815E134 Display of the temperature detected by the needle probe Operate as follows: Make sure that the keyboard is not locked and that no procedure is in progress. Hold the DOWN key down for 1 s: the display will show the first label available.
EVCO S.p.A. EVSX815 | Installer manual ver. 1.3 | Code 144XS815E134 Locking/unlocking the keyboard Operate as follows to lock the keyboard: Make sure no procedures are in progress Hold the DOWN key and the START/STOP key down for 1 s: the display will show “Loc” for 1 s.
EVCO S.p.A. EVSX815 | Installer manual ver. 1.3 | Code 144XS815E134 OPERATION Foreword The devices can manage the following operating cycles: blast chilling and storage hard blast chilling and storage deep freezing and storage soft deep freezing and storage. For further information, see the next paragraphs Every operating cycle can be preceded by pre-cooling;...
EVCO S.p.A. EVSX815 | Installer manual ver. 1.3 | Code 144XS815E134 The maximum blast chilling duration count is started on condition that the temperature detected by the needle probe is below that established with parameter r15. If the test is not completed successfully, the cycle will be started with timed-control.
Page 20
EVCO S.p.A. EVSX815 | Installer manual ver. 1.3 | Code 144XS815E134 Press and release the HARD/SOFT key: the HARD LED will flash. If parameter r19 is set at 0, the display will show the work set-point during blast chilling; this value can also be set via parameter r7.
EVCO S.p.A. EVSX815 | Installer manual ver. 1.3 | Code 144XS815E134 To display the cabinet temperature, press and release the BLAST CHILLING key; to restore the normal display, press and release the BLAST CHILLING key again or do not operate for 15 s.
EVCO S.p.A. EVSX815 | Installer manual ver. 1.3 | Code 144XS815E134 During deep freezing, the display shows the residual time of the deep freezing duration and the is on. To modify the residual time, operate as indicated: 5.2.1 Press and release the UP or DOWN key again to modify the time value: the display will flash.
Page 23
EVCO S.p.A. EVSX815 | Installer manual ver. 1.3 | Code 144XS815E134 If parameter r19 is set at 0, the display will show the work set-point during deep freezing; this value can also be set via parameter r8. If parameter r21 has value 1 and it has been decided to start the cycle with timed-control, the display will show the duration of time-controlled deep freezing;...
EVCO S.p.A. EVSX815 | Installer manual ver. 1.3 | Code 144XS815E134 To display the cabinet temperature, press and release the DEEP FREEZING key; to restore the normal display, press and release the DEEP FREEZING key again or do not operate for 15 s.
EVCO S.p.A. EVSX815 | Installer manual ver. 1.3 | Code 144XS815E134 To start the temperature-controlled cycle, press the BLAST CHILLING key or the DEEP FREEZING key. After 1 min from the signal that the test has not been completed successfully without having operated, the cycle is started with time control.
EVCO S.p.A. EVSX815 | Installer manual ver. 1.3 | Code 144XS815E134 “HACCP” FUNCTION Foreword Using the “HACCP” function, it is possible to memorise up to 9 events for each of the 3 HACCP alarms, after which the most recent event overwrites the oldest.
EVCO S.p.A. EVSX815 | Installer manual ver. 1.3 | Code 144XS815E134 Inf. Meaning the critical value is 8.0 °C/8 °F the display is about to show the date and time the alarm occurred the alarm occurred in 2011 (continue...) the alarm occurred in the month of March (continue...) the alarm occurred on 26 March 2011 the alarm occurred at 16:00 (continue...)
EVCO S.p.A. EVSX815 | Installer manual ver. 1.3 | Code 144XS815E134 COMPRESSOR OPERATING HOURS COUNT Display of compressor operating hours Operate as follows: Make sure that the keyboard is not locked and that no procedure is in progress. Hold the DOWN key down for 1 s: the display will show the first label available.
EVCO S.p.A. EVSX815 | Installer manual ver. 1.3 | Code 144XS815E134 CONFIGURATION Setting the real date and time Operate as follows: Make sure that the keyboard is not locked and that no procedure is in progress. Hold the DOWN key down for 1 s: the display will show the first label available.
EVCO S.p.A. EVSX815 | Installer manual ver. 1.3 | Code 144XS815E134 Press and release the BLAST CHILLING key or do not operate for 15 s: the display will show the parameter label again. Operate as follows to exit the procedure: Hold the UP and DOWN key for 4 s or do not operate for 60 s The display will show the magnitude indicated in paragraph 5.3 "The display".
Page 31
EVCO S.p.A. EVSX815 | Installer manual ver. 1.3 | Code 144XS815E134 probe type - - - - = PTC = NTC °C decimal point - - - - = yes temperature unit of measurement (2) - - - - = °C = °F...
Page 32
EVCO S.p.A. EVSX815 | Installer manual ver. 1.3 | Code 144XS815E134 work set-point during blast chilling; also work set-point -50.0 99.0 °C/°F (1) during the soft deep freezing phase (cabinet temperature); see also parameter r0 work set-point during deep freezing (cabinet temperature);...
Page 33
EVCO S.p.A. EVSX815 | Installer manual ver. 1.3 | Code 144XS815E134 "temperature detected by the needle probe - cabinet temperature" minimum difference such to consider the first phase of the test to verify correct insertion of the needle 99.0 °C/°F (1)
Page 34
EVCO S.p.A. EVSX815 | Installer manual ver. 1.3 | Code 144XS815E134 minimum time between restoring the power supply after a power cut, occurring during an operating cycle and compressor switch-on minimum time between two consecutive compressor switch- ons (3) minimum...
Page 35
EVCO S.p.A. EVSX815 | Installer manual ver. 1.3 | Code 144XS815E134 type of defrosting = electrical (the compressor will be switched off during defrosting, the defrosting output will be activated and the evaporator fan will be switched off) = hot gas (the compressor will be switched on during...
Page 36
EVCO S.p.A. EVSX815 | Installer manual ver. 1.3 | Code 144XS815E134 duration of pre-dripping (only if parameter d1 is set at 1; the compressor and evaporator fan will be off during pre- dripping and the defrosting output will remain activated) Par.
Page 37
EVCO S.p.A. EVSX815 | Installer manual ver. 1.3 | Code 144XS815E134 memorisation of the temperature-controlled blast chilling or temperature-controlled deep freezing non concluded within - - - - maximum duration alarm (“tiME”) = yes Par. Min. Max. Unit Default Evaporator and condenser fan...
Page 38
EVCO S.p.A. EVSX815 | Installer manual ver. 1.3 | Code 144XS815E134 evaporator temperature above which the evaporator fan is -50.0 99.0 °C/°F (1) 20.0 off during pre-cooling, blast chilling and deep freezing (only if parameter F0 is set at 1); see also parameter XS8 (10) cabinet temperature above which the evaporator fan is off -50.0...
Page 39
EVCO S.p.A. EVSX815 | Installer manual ver. 1.3 | Code 144XS815E134 type of high pressure input 1 - - - - = normally open (input active with closed contact) = normally closed (input active with open contact) high pressure alarm signalling delay (“HP” code) -1 = the alarm will not be signalled Par.
EVCO S.p.A. EVSX815 | Installer manual ver. 1.3 | Code 144XS815E134 SIGNALS AND INDICATIONS 10.1 Signals The following table illustrates the meaning of the signalling LEDS. Meaning Blast chilling LED. If it is on: blast chilling in progress. If flashing: a blast chilling and storage cycle will have been selected.
Page 42
EVCO S.p.A. EVSX815 | Installer manual ver. 1.3 | Code 144XS815E134 Defrosting LED. If it is on: defrosting will be in progress. Pre-cooling LED. If it is on: pre-cooling will be in progress and the cabinet temperature will have reached that established using parameter r12.
EVCO S.p.A. EVSX815 | Installer manual ver. 1.3 | Code 144XS815E134 10.2 Indications The following table illustrates the meaning of the indication codes. Code Meaning The keyboard is locked, see paragraph 5.10 "Lock/unlock the keyboard". The keyboard has been locked, see paragraph 5.10 "Lock/unlock the keyboard".
EVCO S.p.A. EVSX815 | Installer manual ver. 1.3 | Code 144XS815E134 ALARMS 11.1 Alarms The following table illustrates the meaning of the alarm codes. Code Meaning Temperature-controlled blast chilling or deep freezing not concluded within maximum duration alarm (HACCP alarm).
Page 45
EVCO S.p.A. EVSX815 | Installer manual ver. 1.3 | Code 144XS815E134 Configuration parameters download not completed successfully alarm. Solutions: press and release a key to restore normal display download the configuration parameters again. Main consequences: the device will continue to operate normally.
EVCO S.p.A. EVSX815 | Installer manual ver. 1.3 | Code 144XS815E134 ERRORS 12.1 Errors The following table illustrates the meaning of the error codes. Code Meaning Cabinet probe error. Solutions: check the value of the parameter P0 check the integrity of the probe check the device-probe connection check the temperature of the cabinet.
Page 47
EVCO S.p.A. EVSX815 | Installer manual ver. 1.3 | Code 144XS815E134 Clock error. Solutions: set the real date and time again. Main consequences: the device does not memorise the date or time at which the HACCP alarm occurred or its duration.
EVCO S.p.A. EVSX815 | Installer manual ver. 1.3 | Code 144XS815E134 ACCESSORIES 13.1 EVKEY programming key 13.1.1 Introduction EVKEY is a programming key. The key can be used to upload and download the configuration parameters. The key can be used on condition that the device is powered.
EVCO S.p.A. EVSX815 | Installer manual ver. 1.3 | Code 144XS815E134 13.1.3 Dimensions The following drawing illustrates the EVKEY dimensions; these are expressed in mm (in). 13.1.4 Uploading the configuration parameters Operate as follows: Cut the device power supply off.
EVCO S.p.A. EVSX815 | Installer manual ver. 1.3 | Code 144XS815E134 Press and release a key to restore normal display. Disconnect the EVKEY Micromatch connector into the device communication port. Operate as follows to abandon the procedure: Do not operate for 60 s.
EVCO S.p.A. EVSX815 | Installer manual ver. 1.3 | Code 144XS815E134 For further information, consult the documentation relative to RICS and EVUSBREC01. 13.3 EVPROG01 connection kit 13.3.1 Introduction EVPROG01 is a connection kit. The kit can be used to connect the device to the Parameters Manager set-up software system.
EVCO S.p.A. EVSX815 | Installer manual ver. 1.3 | Code 144XS815E134 The following table illustrates the meaning of EVIF20TRX parts. Part Meaning RS-232 port TTL door on moveable support TTL door on rigid support reserved non-optoisolated RS-232/TTL serial interface EVIF20TRX...
EVCO S.p.A. EVSX815 | Installer manual ver. 1.3 | Code 144XS815E134 13.3.4 Connection to the device Operate as follows: Insert the EVIF20TRX TTL port inside the device communication port (use the port on the support that seems easiest to use).
EVCO S.p.A. EVSX815 | Installer manual ver. 1.3 | Code 144XS815E134 TECHNICAL DATA 14.1 Technical data Purpose of the device: blast chiller controller. user interface control module Execution: board without cover board without cover. user interface control module Dimensions: 99.0 x 108.0 x 24.0 mm (3.897 156.0 x 45.0 x 24.0 mm (6.141...
Page 55
EVCO S.p.A. EVSX815 | Installer manual ver. 1.3 | Code 144XS815E134 supplied from control 115... (±15%), module. 50/60 Hz (±3 Hz), 10 VA max. Overvoltage category: III. incorporated (with condenser). Battery autonomy in the event of a power-cut: 24 h with battery Clock: fully charged.
Page 56
EVCO S.p.A. EVSX815 | Installer manual ver. 1.3 | Code 144XS815E134 5 outputs (electromechanical relays): 1 SPST (K1) 30 A res. output @ 250 VAC for compressor management 2 x 16 A res. outputs @ 250 VAC of which one SPDT (K2)
Page 59
This document is exclusive property of Evco; reproduction and disclosure are prohibited without express authorisation from Evco. Evco is not liable for any features, technical data and possible errors stated in this document or deriving from use of the same.