Split execution controller for temperature-controlled blast chillers (with capacitive touch-key user interface, which can be integrated into the unit) (58 pages)
Digital controller for refrigerated cabinets, made up from user interface with capacitive touch keys (integrated into the unit) and a control module (9 pages)
Digital controller for refrigerated cabinets, made up from user interface with capacitive touch keys (integrated into the unit) and a control module (8 pages)
Digital controller for refrigerated cabinets, made up from user interface with capacitive touch keys (integrated into the unit) and a control module (8 pages)
Digital controller for refrigerated cabinets, made up from user interface with capacitive touch keys (integrated into the unit) and a control module (8 pages)
Controllers for top-class blast chillers, in split version that can be built into the unit, with 5- or 7-inch colour tft touch-screen graphic display in either vertical or horizontal format (84 pages)
Summary of Contents for Evco EVF 300 Series
Page 1
EVCO S.p.A. EVF 300 series | Installer manual ver. 1.3 | Code 144F300E134 EVF 300 series Controllers for electric bread and pizza ovens, with touch-keys, in split version and which can be integrated into the unit. Installer manual| ENGLISH Code 144F300E134...
Page 2
EVCO S.p.A. EVF 300 series | Installer manual ver. 1.3 | Code 144F300E134 Important Read this document thoroughly before installation and before use of the device and follow all recommendations; keep this document with the device for future consultation. Only use the device in the way described in this document; do not use the same as a safety device.
EVCO S.p.A. EVF 300 series | Installer manual ver. 1.3 | Code 144F300E134 Index "QUICK HEATING" FUNCTION (only if the CFG parameter is set at 0) ........30 INTRODUCTION ..........4 12.1 Preliminary notes .......... 30 Introduction ........... 4 12.2 Activation of the "quick heating"...
EVCO S.p.A. EVF 300 series | Installer manual ver. 1.3 | Code 144F300E134 INTRODUCTION Introduction EVF 300 series is a range of elegant controllers for the management of electric bread and pizza ovens. They are available in the split version and can be integrated both mechanically and aesthetically into the unit;...
EVCO S.p.A. EVF 300 series | Installer manual ver. 1.3 | Code 144F300E134 Summary table of the models available, the main features and the purchase codes The following table illustrates the models available. Models available: EVF318 EVF328 The following table illustrates the main features of the devices.
Page 6
EVCO S.p.A. EVF 300 series | Installer manual ver. 1.3 | Code 144F300E134 circuit breaker protection • • electric absorption protection • • Digital outputs: EVF318 EVF328 8 A res. @ 250 VAC electro- 8 A res. @ 250 VAC electro-...
Page 7
EVCO S.p.A. EVF 300 series | Installer manual ver. 1.3 | Code 144F300E134 "cooking timer" function • • “programs” function • • "weekly programmed switch-on" function • • “energy saving” function • • "quick heating" function • • configuration parameters access password •...
EVCO S.p.A. EVF 300 series | Installer manual ver. 1.3 | Code 144F300E134 DIMENSIONS AND INSTALLATION User interface dimensions and installation The following drawing illustrates the devices' user interface dimensions; these are expressed in mm (in). Installation is envisioned at the rear of the panel with biadhesive tape.
EVCO S.p.A. EVF 300 series | Installer manual ver. 1.3 | Code 144F300E134 Installation warnings make sure that the device work conditions (temperature of use, humidity, etc.) lie within the limits indicated; see chapter 19 “TECHNICAL DATA” do not install the device near to any heat sources (heating elements, hot air ducts etc.), equipment containing powerful magnets (large diffusers, etc.), areas affected by direct sunlight, rain, humidity, excessive dust, mechanical vibrations or...
EVCO S.p.A. EVF 300 series | Installer manual ver. 1.3 | Code 144F300E134 ELECTRIC CONNECTION Electric connection The following drawing illustrates the devices' electric connection. The utility managed by the K4 digital output, depends on the configuration parameter u1, as follows: extraction hood (parameter u1 = 0, factory setting) multifunction (u1 = 1).
EVCO S.p.A. EVF 300 series | Installer manual ver. 1.3 | Code 144F300E134 The RS-485 port is the communication port with the following EVCO products: parameters Manager set-up software system device for recording data and to download recorded data (via USB) EVUSBREC01.
EVCO S.p.A. EVF 300 series | Installer manual ver. 1.3 | Code 144F300E134 DESCRIPTION Description of the user interface The following drawing illustrates the aspect of the devices' user interface. The following table illustrates the meaning of devices' control module parts.
EVCO S.p.A. EVF 300 series | Installer manual ver. 1.3 | Code 144F300E134 "UPPER" display "ON/OFF" key, herein called also "ON/STAND-BY" key "TOP" key "PROGRAMS" key “STEAM INJECTION” key For further information, see the next chapters. Description of the control module The following drawing illustrates the aspect of the devices' control module.
Page 14
EVCO S.p.A. EVF 300 series | Installer manual ver. 1.3 | Code 144F300E134 TTL port reserved analogue inputs reserved RS-485 port and communication port with user interface Page 14 of 62...
EVCO S.p.A. EVF 300 series | Installer manual ver. 1.3 | Code 144F300E134 COMMISSIONING Commissioning Operate as indicated: Install the device using the methods illustrated in the 2 “DIMENSIONS AND INSTALLATION” chapter, following all warnings given in the 3.2 “Installation warnings” paragraph.
Page 16
EVCO S.p.A. EVF 300 series | Installer manual ver. 1.3 | Code 144F300E134 utility managed by the digital output K5 technical compartment fan switch-on/off acoustic Successively, check that the remaining settings are appropriate; see paragraph 14.7 “List of configuration parameters”.
EVCO S.p.A. EVF 300 series | Installer manual ver. 1.3 | Code 144F300E134 USER INTERFACE 6.4.2 The bottom part of the "UPPER" display If the device is on, the bottom part of the "UPPER" display will Device switch-on/off in manual show the value of the cooking timer.
EVCO S.p.A. EVF 300 series | Installer manual ver. 1.3 | Code 144F300E134 If the "weekly programmed switch-on" function has been activated, the bottom part of the "LOWER" display will be off. If the device is off, the bottom part of the "LOWER" display will be off.
EVCO S.p.A. EVF 300 series | Installer manual ver. 1.3 | Code 144F300E134 MANAGEMENT OF UTILITIES Press and release the "STEAM GENERATOR" key or do not operate for 15 sec: the “T ” LED and the Steam injection bottom part of the "LOWER" display will remain on 7.1.1...
EVCO S.p.A. EVF 300 series | Installer manual ver. 1.3 | Code 144F300E134 Operate as follows to exit the procedure before the operation Steam generator is complete: 7.2.1 Preliminary notes Do not operate for 15 sec (any changes will be Steam generator activity depends mainly on parameter P4, as saved).
EVCO S.p.A. EVF 300 series | Installer manual ver. 1.3 | Code 144F300E134 Vents 7.5.2 Output switch-on/off (only if parameter u11 is set at 1) 7.3.1 Preliminary notes The activity of the output switch-on/off depends mainly on the Pressing and releasing the "VENT" key will cause the activation...
EVCO S.p.A. EVF 300 series | Installer manual ver. 1.3 | Code 144F300E134 if the CFG parameter is set at 1, the output will be switched-on until the temperature of the floor has reached the floor set-point and will be switched back on when the temperature falls below that established with parameter r6 (i.e.
EVCO S.p.A. EVF 300 series | Installer manual ver. 1.3 | Code 144F300E134 "COOKING TIMER" FUNCTION Preliminary notes The "cooking timer" function allows to start the residual count of a time. Start-up of the cooking timer count causes the start-up of the cooking cycle;...
EVCO S.p.A. EVF 300 series | Installer manual ver. 1.3 | Code 144F300E134 Operate as follows to exit the procedure before the operation is complete: Do not operate for 15 sec (any changes will be saved). If the cooking timer is set during the count, this modification will not be saved.
EVCO S.p.A. EVF 300 series | Installer manual ver. 1.3 | Code 144F300E134 “PROGRAMS” FUNCTION Preliminary notes The "programs" function allows to memorise several settings in a program; on program start-up the device will operate with the settings memorised in the same.
EVCO S.p.A. EVF 300 series | Installer manual ver. 1.3 | Code 144F300E134 Hold the “PROGRAMS” key down for 1 s: the device will leave the procedure. Operate as follows to exit the procedure before the operation is complete: Do not operate for 15 sec (any changes will not be saved).
EVCO S.p.A. EVF 300 series | Installer manual ver. 1.3 | Code 144F300E134 "WEEKLY PROGRAMMED SWITCH-ON" FUNCTION 10.1 Preliminary notes The “weekly programmed switch-on” function allows to program device switch-on and simultaneously start a program; FUNCTION see chapter ““PROGRAMS” ”.
EVCO S.p.A. EVF 300 series | Installer manual ver. 1.3 | Code 144F300E134 Operate as follows to set the switch-on time: hours, press release “PROGRAMS” key while setting the program to be started: the hours value will flash. Press and release the UP or DOWN key within 15 s to set the value of the hours.
EVCO S.p.A. EVF 300 series | Installer manual ver. 1.3 | Code 144F300E134 If a weekly programmed switch-on is modified by pressing and releasing the “PROGRAMS” key, of the “UP” key and the “DOWN” key after the function has been activated, this modification will not be saved.
EVCO S.p.A. EVF 300 series | Installer manual ver. 1.3 | Code 144F300E134 “ENERGY SAVING” FUNCTION "QUICK HEATING" FUNCTION 11.1 Preliminary notes (only if the CFG parameter is The "energy saving" function allows to reduce the electric set at 0) absorption of the top output and the floor output, accessing 12.1...
EVCO S.p.A. EVF 300 series | Installer manual ver. 1.3 | Code 144F300E134 CONFIGURATION 14.1 Setting the day of the week and the time The day of the week is displayed in the 1...7 format (number 1 corresponds to Monday);the time is displayed in the 24 h format (hours:minutes).
EVCO S.p.A. EVF 300 series | Installer manual ver. 1.3 | Code 144F300E134 Setting the day of the week and the time 14.2 Setting work set-point (only if the CFG parameter is set at 0) Operate as follows to set the work set-point: Ensure that the device is switched on and that no other procedure is in progress.
EVCO S.p.A. EVF 300 series | Installer manual ver. 1.3 | Code 144F300E134 Operate as follows to set the floor set-point: Ensure that the device is switched on and that no other procedure is in progress. Press and release the "FLOOR" key: the and the LED of the “LOWER”...
EVCO S.p.A. EVF 300 series | Installer manual ver. 1.3 | Code 144F300E134 Operate as follows to set the power distributed at the floor: Ensure that the device is switched on and that no other procedure is in progress. Press and release the "FLOOR" key twice: the LED of the “LOWER”...
EVCO S.p.A. EVF 300 series | Installer manual ver. 1.3 | Code 144F300E134 Operate as follows to set a parameter: Press and release the “TOP” key or the “FLOOR” key: the top part of the “LOWER” display will show the value of the parameter.
Page 36
EVCO S.p.A. EVF 300 series | Installer manual ver. 1.3 | Code 144F300E134 Operate as follows to exit the procedure before the operation is complete: Hold the “UP” key and “DOWN” key down for 4 s before setting “1” (i.e. before point 8: restore will not be performed).
EVCO S.p.A. EVF 300 series | Installer manual ver. 1.3 | Code 144F300E134 14.7 List of configuration parameters The following table illustrates the meaning of the device configuration parameters. The indication “1 ING.” indicates “operating with an analogue input” (chamber probe, i.e. with management of the power distributed at the top and that distributed at the floor independently from each other;...
Page 38
EVCO S.p.A. EVF 300 series | Installer manual ver. 1.3 | Code 144F300E134 type of operation with one analogue input (chamber probe, i.e. with management of the power supplied at the top and at the floor independently from each - - - other.)
Page 39
EVCO S.p.A. EVF 300 series | Installer manual ver. 1.3 | Code 144F300E134 information shown in the top part of the "LOWER" display when the device is on and when a cooking cycle is in progress if CFG = 0, power distributed at the top...
Page 40
EVCO S.p.A. EVF 300 series | Installer manual ver. 1.3 | Code 144F300E134 PARAM. MIN. MAX. U.M. INP. 1 INP. 2 STEAM INJECTION °C/°F (1) steam set-point; see also t3 (only if P4 = 2) steam injection activation mode MANUAL + PERSISTENT MANUAL - pressing and releasing the “STEAM INJECTION”...
Page 41
EVCO S.p.A. EVF 300 series | Installer manual ver. 1.3 | Code 144F300E134 enabling of the restriction between steam injection in cyclic mode and conclusion of the cooking timer count (only if t0 = 1) - - - YES - on conclusion of the cooking timer count, the steam injection in cyclic mode will be deactivated;...
Page 42
EVCO S.p.A. EVF 300 series | Installer manual ver. 1.3 | Code 144F300E134 time that must pass in absence of operations on keys (from device switch-on due to effect of the "weekly programmed switch-on" function), until the function is activated again percentage reduction of the switch-on durations of the not dis.
Page 43
EVCO S.p.A. EVF 300 series | Installer manual ver. 1.3 | Code 144F300E134 effect caused by the activation of the door micro switch input no effect EXTRACTION HOOD SWITCH-ON - the extraction hood will switched (only u1 = 0, until the input is deactivated)
Page 44
EVCO S.p.A. EVF 300 series | Installer manual ver. 1.3 | Code 144F300E134 effect caused by the activation of the electric absorption protection input DISABLING STEAM INJECTION, SWITCH-OFF OF STEAM GENERATOR, OF THE TOP OUTPUT AND THE FLOOR OUTPUT - steam injection will be...
Page 45
EVCO S.p.A. EVF 300 series | Installer manual ver. 1.3 | Code 144F300E134 parity none (no parity) - - - even Notes The unit of measurement depends on parameter P2. Properly set the parameters corresponding to the regulators after setting parameter P2.
EVCO S.p.A. EVF 300 series | Installer manual ver. 1.3 | Code 144F300E134 SIGNALS 15.1 Signals The following table illustrates the meaning of the device LEDS. MEANING if the parameter CFG is set at 0, chamber LED if it is on, the top output and/or the floor output will be on if it flashes, setting of the work set-point will be in progress (with the procedure illustrated in paragraph 14.2)
Page 47
EVCO S.p.A. EVF 300 series | Installer manual ver. 1.3 | Code 144F300E134 temperature associated to the floor LED if it is on, the value displayed in the top part of the display will be a temperature associated to the floor in the "LOWER"...
EVCO S.p.A. EVF 300 series | Installer manual ver. 1.3 | Code 144F300E134 ALARMS 16.1 Alarms The following table illustrates the meaning of the device alarm codes. CODE MEANING if the parameter CFG is set at 0, temperature solutions: check the chamber temperature; see parameters A1 and A3...
Page 49
EVCO S.p.A. EVF 300 series | Installer manual ver. 1.3 | Code 144F300E134 electric absorption protection input alarm solutions: check the causes of the activation of the input; see parameter i16, main consequences: if the alarm occurs when the device is on, a cooking cycle cannot be started...
Page 50
EVCO S.p.A. EVF 300 series | Installer manual ver. 1.3 | Code 144F300E134 device settings upload not completed successfully alarm solutions: to restore the factory settings main consequences: all outputs will be switched off device settings download not completed successfully alarm...
EVCO S.p.A. EVF 300 series | Installer manual ver. 1.3 | Code 144F300E134 ERRORS 17.1 Errors The following table illustrates the meaning of the device error codes. CODE MEANING if the parameter CFG is set at 0, chamber probe error...
Page 52
EVCO S.p.A. EVF 300 series | Installer manual ver. 1.3 | Code 144F300E134 user interface-control module communication error solutions: check user interface-control module control module main consequences: if the alarm occurs when the device is on, a cooking cycle cannot be started...
EVCO S.p.A. EVF 300 series | Installer manual ver. 1.3 | Code 144F300E134 ACCESSORIES 18.1 EVKEY programming key 18.1.1 Preliminary notes EVKEY is a programming key. Using the key it is possible to upload and download the device settings (configuration parameters, information relative to programs and weekly programmed switch-ons);...
EVCO S.p.A. EVF 300 series | Installer manual ver. 1.3 | Code 144F300E134 Do not operate for 60 s. Disconnect the EVKEY Micromatch connector from the device control module TTL serial port (upload will not be performed). For further information, see the documentation relative to EVKEY.
EVCO S.p.A. EVF 300 series | Installer manual ver. 1.3 | Code 144F300E134 The following table illustrates the meaning of the EVIF20SUXI parts. PART MEANING USB cable (length of 2 m) telephone cable (length of 2.5 m) RS-485 port on telephone connector...
Page 56
EVCO S.p.A. EVF 300 series | Installer manual ver. 1.3 | Code 144F300E134 The following table illustrates the meaning of the EVUSBREC01 parts. PART MEANING USB port RS-485 port power supply For further information, see the next paragraphs 18.3.3 Connecting the device Operate as follows to connect the devices: Cut the device power supply off.
EVCO S.p.A. EVF 300 series | Installer manual ver. 1.3 | Code 144F300E134 TECHNICAL DATA 19.1 Technical data Purpose of the command device: operating command device. Construction of the command device: built-in electronic device. user interface control module Case: board without cover fixed onto a board without cover.
Page 58
EVCO S.p.A. EVF 300 series | Installer manual ver. 1.3 | Code 144F300E134 Rated impulse voltage: 4 KV. Overvoltage category: Class and structure of software: incorporated (with condenser). Battery autonomy in the event of a power-cut: 24 h with battery fully charged.
Page 59
EVCO S.p.A. EVF 300 series | Installer manual ver. 1.3 | Code 144F300E134 8 outputs (electro-mechanical relays) in the EVF318 model 1 x 8 A res. output @ 250 VAC SPST type (K1) for steam injection management 1 x 8 A res. output @ 250 VAC SPST type (K2) for steam generator management 1 x 8 A res.
Page 60
EVCO S.p.A. EVF 300 series | Installer manual ver. 1.3 | Code 144F300E134 2 ports: 1 x TTL serial port (for EVKEY programming) Communication ports: 1 RS-48 serial port with MODBUS communication protocol (for other EVCO products). Signal buzzer and alarm: incorporated.
Page 61
EVCO S.p.A. EVF 300 series | Installer manual ver. 1.3 | Code 144F300E134 EVF 300 series Controllers for electric bread and pizza ovens, with touch-keys, in split version and which can be integrated into the unit Installer manual ver. 1.3...
Need help?
Do you have a question about the EVF 300 Series and is the answer not in the manual?