Download Print this page

ZURN AquaVantage Z6000AV Series Installation, Operation, Maintenance And Parts Manual

Aquavantage exposed flushometer

Advertisement

Quick Links

AquaVantage Exposed
Closet/Urinal Systems
Z6000AV
Z6000AV-HET
Z6001AV
Z6003AV
Z6003AV-ULF
NOTICE: READ ENTIRE MANUAL PRIOR TO INSTALLING PRODUCT.
WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
ADVERTENCIA: Cáncer y daño reproductivo - www.P65Warnings.ca.gov
AVERTISSEMENT: Cancer et effets néfastes sur la reproduction - www.P65Warnings.ca.gov
All goods sold hereunder are warranted to be free from defects in material and factory workmanship for a period of three years from the
date of purchase. Decorative finishes warranted for one year. We will replace at no costs goods that prove defective provided we are
notified in writing of such defect and the goods are returned to us prepaid at Sanford, NC, with evidence that they have been properly
maintained and used in accordance with instructions. We shall not be responsible for any labor charges or any loss, injury or damages
whatsoever, including incidental or consequential damages. The sole and exclusive remedy shall be limited to the replacement of the
defective goods. Before installation and use, the purchaser shall determine the suitability of the product for his intended use and the
purchaser assume all risk and liability whatever in connection therewith. Where permitted by law, the implied warranty of merchantability
is expressly excluded. If the products sold hereunder are "consumer products," the implied warranty of merchantability is limited to a
period of three years and shall be limited solely to the replacement of the defective goods. All weights stated in our catalogs and listed
are approximate and are not guaranteed.
NOTE: The information in this manual is subject to change at any time without notice. Installations may
be performed at different times of construction by different individuals. For this reason, these instructions
should be left on-site with the facility or maintenance manager.
Rev. C | Date: 11/08/22 | C.N. No. 144844 | Prod./Dwg. No. FV211
Patent zurn.com/patents
US 1.855.ONE.ZURN CANADA 1.877.892.5216
ZURN.COM
Z6000AV
Z6010AV
Z6014AV
Z6017AV
Z6096AV
Z6099AV
LIMITED WARRANTY
AquaVantage
Z6000AV Series
AquaVantage Exposed Flushometer
Installation, Operation, Maintenance
and Parts Manual
®
Z6003AV

Advertisement

loading
Need help?

Need help?

Do you have a question about the AquaVantage Z6000AV Series and is the answer not in the manual?

Questions and answers

Summary of Contents for ZURN AquaVantage Z6000AV Series

  • Page 1 For this reason, these instructions should be left on-site with the facility or maintenance manager. Rev. C | Date: 11/08/22 | C.N. No. 144844 | Prod./Dwg. No. FV211 Patent zurn.com/patents US 1.855.ONE.ZURN CANADA 1.877.892.5216 ZURN.COM...
  • Page 2 Full Flow type, chrome-plated flushometer valve with a polished exterior. 3.0 Gal. for Urinal, 4.5 Gal. for Water Closet Complete with Zurn’s AquaVantage TPE, chloramine resistant, -HET High Efficiency Toilet dual seal diaphragm with a clog resistant, triple filtered by-pass.
  • Page 3 The Aquaflush valve is designed to operate under various water pressures with a recommended range between 10 and 100 psi (69 to 689 kPa). Each Zurn valve is tested for proper performance at the factory before being shipped. Consult the product pages of the catalog for available flow options.
  • Page 4 AquaVantage Installation Instructions ® 1. Install stop valve assembly using proper size supply 3. Insert the flush valve tailpiece into the stop valve and hand escutcheon and sweat solder adapter kit if applicable (see tighten the lock nut to the stop valve. Plumb the entire unit 1).
  • Page 5 AquaVantage Installation Instructions ® 6. When all flush valves are connected to the fixtures and water pressure is available, it is recommended that the supply piping be flushed to remove dirt, pipe chips, etc. from system. Before the water is turned on, be sure all stop valves to the flush valves are closed off tight.
  • Page 6 AquaVantage Repair Kits ® Part Identification 1. Handle Nut 2. Handle 3. Actuator Rod 4. Handle O-Ring 5. Handle Spring 6. Handle Seal Retainer 7. Handle Seal 8. Handle Gasket 9. Valve Body Cover 10. Plastic Wrap 11. Trip Mechanism 12.
  • Page 7 AquaVantage Trouble Shooting Guide ® Problem Cause* Corrective Action* Valve will not operate. 1.) Stop valve is closed. 1.) Open stop valve. 2.) Supply valve is closed. 2.) Open supply valve. Insufficient volume of wa- "1.) Stop valve is not open enough. 1.) Open stop valve for desired volume of water.
  • Page 8 ZURN INDUSTRIES, LLC COMMERCIAL BRASS OPERATION, 5900 ELWIN BUCHANAN DRIVE, SANFORD, NC, U.S.A. 27330 PHONE: 1-800-997-3876 FAX: 919/775-3541 www.zurn.com ZURN INDUSTRIES LIMITED 3544 NASHUA DRIVE, MISSISSAUGA, ONTARIO L4V 1L2 PHONE: 905/405-8272 FAX: 905/405-1292 FV211 Rev. C 11/08/22 Page 8...