THANK YOU Dear Valued Customer, SUMERAIN would like to take this opportunity to thank you for purchasing SUMERAIN products. It is our sincere hope that you are completely satisfied with your new purchase. All SUMERAIN products are carefully engineered, and factory tested to provide long trouble-free use under normal conditions. This product is easy to install using basic tools and our easy to follow illustrated instructions.
This warranty covers only your SUMERAIN manufactured product. SUMERAIN warrants this product against defects in material or workmanship as follows: SUMERAIN will repair at no charge for parts only or, at its option, replace any product or part of the product that proves defective because of improper workmanship and/or material, under normal installation, use, service and maintenance.
Page 4
30.0L/M [ 7.92 GPM ] Spout Max Flow rate Brass Spout Material 6-5/8 Inch [168mm] Spout Reach 1-3/4 Inch [45mm] Spout width 6,72lbs [3,05KG] Net Weight 7,71lbs [3,5KG] Gross Weight 11-1/4”[285mm]x10-13/16”[275mm]x7-7/8” [200mm] Packing box [L x W x H] SUMERAIN SANITARY GROUP WWW.SUMERAIN.COM...
Page 5
DIMENSION FRONT VIEW OF SHOWER SIDE VIEW OF SHOWER SUMERAIN SANITARY GROUP WWW.SUMERAIN.COM...
2132025 Hand shower 1 PCS 2132026 Mounting screw 4 PCS 2132027 Anchor 4 PCS 2132028 Hand shower hose 1 PCS If any of these items are missing, please contact SUMERAIN consumer service by email to: supports@sumerain.com SUMERAIN SANITARY GROUP WWW.SUMERAIN.COM...
Page 7
5. CONCEALED BOX ASSEMBLY INSTALLATION 5.1 Make a mounting rack (normally use woods as materials) for preparing install the concealed box assembly .the mounting board’s face should be Min 65mm [2-17/32"] and Max 90mm [3-17/32"] behind the finish wall surface. SUMERAIN SANITARY GROUP WWW.SUMERAIN.COM...
Page 8
6.1 Turn on your shut-off valve for cleaning the hot and cold water supply pipe before connect to the valve body, allow the water flush 3~5 minutes to flush out dirt and debris. Shut off the water supply again after finish. HOT WATER SUPPLY COLD WATER SUPPLY SUMERAIN SANITARY GROUP WWW.SUMERAIN.COM...
Page 9
6.2 Apply Teflon tape on the thread of pipe inlet and then connect to valve inlet with elbow [hot left, cold right]. Mixer Valve Connecting thread for Hot&Cold water Mixer Valve inlet thread: NPT1/2 (US, CA) G1/2” [1/2 BSPP] (UK, Europe etc.) Connect to valve outlet with elbow: SUMERAIN SANITARY GROUP WWW.SUMERAIN.COM...
Page 10
6.3 Drill the mounting holes exactly according to mixer valve and elbow position, done the finish wall. SUMERAIN SANITARY GROUP WWW.SUMERAIN.COM...
Page 11
Please shut off your hot and cold water supply again if no leaking. 6.5 Cut the plaster shield around the finish wall surface and seal the wall around the plaster shield with waterproof sealant WARNING: Failure to seal the wall can lead to possible water damage. SUMERAIN SANITARY GROUP WWW.SUMERAIN.COM...
Page 12
6.6 Remove the valve sleeve by Phillips screwdriver and hold the screw for next step. SUMERAIN SANITARY GROUP WWW.SUMERAIN.COM...
Page 13
6.7 Attach the escutcheon over the valve body. 6.8 Seal the wall around the plaster shield with waterproof sealant SUMERAIN SANITARY GROUP WWW.SUMERAIN.COM...
Page 14
6.9 Attach handle onto the valve stem and tighten set screws by the Allen wrench that is provided. Please don’t over tighten. Done the same procedure on diverter knob. Finally press-in the screw cover. 6.10 Valve trim install finish. SUMERAIN SANITARY GROUP WWW.SUMERAIN.COM...
Page 15
7.1 Loose the set screws by Allen key and remove the spout nipple assembly from tub spout assembly. 7.2 Remove the aerator lock nut by adjustable wrench and disassemble all inside parts from the spout nipple supply. SUMERAIN SANITARY GROUP WWW.SUMERAIN.COM...
Page 16
7.3 Apply Teflon tape on the thread of spout nipple supply and screw the thread into the pipe elbow inside the wall. 7.4. Reinstall the aerator lock nut and all inside parts to the spout nipple supply by adjustable wrench. SUMERAIN SANITARY GROUP WWW.SUMERAIN.COM...
Page 17
7.5. Push the flange to tub spout from behind. 7.6. Docking the tub spout to the spout nipple supply and secure with set screw by Allen Key. SUMERAIN SANITARY GROUP WWW.SUMERAIN.COM...
Page 18
7.7. Attach the flange to finish wall. 7.8. Seal the wall around the flange with waterproof sealant. SUMERAIN SANITARY GROUP WWW.SUMERAIN.COM...
Page 19
7.9 Tub spout Install finish. 8. HAND SHOWER INSTALLATION 8.1 Apply Teflon tape on the thread of wall supply elbow. SUMERAIN SANITARY GROUP WWW.SUMERAIN.COM...
Page 20
8.2 Push the flange to supply elbow from behind. 8.3 Screw the wall supply elbow into the pipe elbow inside the wall.. SUMERAIN SANITARY GROUP WWW.SUMERAIN.COM...
9.1 Turn on hold and cold water supply and check all connection for ensuring no leaking anywhere. 10. FUNCTION INSPECTION 10.1 Turn on the hot or cold knob respectively, the water outflow from the spout in turn. 10.2 Switch the diverter Knob, the water will rush from the handshower SUMERAIN SANITARY GROUP WWW.SUMERAIN.COM...
Page 22
Please note: if the surface is already damaged, the effect of cleaning materials will cause further damage. Components with damaged surfaces must be replaced or injury could result. Damage caused by improper treatment is not covered under the warranty. HONGKONG SUMERAIN SANITARY INDUSTRY CO., LIMITED Address: ROOM 1018, HOLLYWOOD PLAZA 610 NATHAN ROAD MONGKOK, KL,HONGKONG...
Need help?
Do you have a question about the S2132XW and is the answer not in the manual?
Questions and answers