  • Page 1 40 HEX PANEL IP User Instructions...
  • Page 2: Document Version

    ©2025 ADJ Products, LLC all rights reserved. Information, specifications, diagrams, images, and instructions herein are subject to change without notice. ADJ Products, LLC logo and identifying product names and numbers herein are trademarks of ADJ Products, LLC. Copyright protection claimed includes all forms and matters of copyrightable materials and information now allowed by statutory or judicial law or hereinafter granted.
  • Page 3: Table Of Contents

    C O N T E N T S General Information IP65 Rated Limited Warranty (USA Only) Warranty Registration / Features Safety Guidelines Overview Torque Settings for Screws IP Test Parameters Installation Guidelines Accessory Installation Wireless Operation Fan Modes and Low Noise Operation System Menu Dimmer Modes &...
  • Page 4 I N T R O D U C T I O N Unpacking: Thank you for purchasing the 40 Hex Panel IP by ADJ Products, LLC. Every device has been thoroughly tested and has been shipped in perfect operating condition. Carefully check the shipping carton for damage that may have occurred during shipping.
  • Page 5: Ip65 Rated

    10,000-hours. This is a prophylactic measure intended to keep the unit running as cool as possible, insuring proper function of all internal components. A complete service breakdown is available, please contact service@adj.com for any needed parts or manuals.
  • Page 6: Limited Warranty (Usa Only)

    All shipping charges must be pre-paid. If the requested repairs or service (including parts replacement) are within the terms of this warranty, ADJ Products, LLC will pay return shipping charges only to a designated point within the United States. If the entire instrument is sent, it must be shipped in its original package. No accessories should be shipped with the product.
  • Page 7: Warranty Registration / Features

    WA R R A N T Y R E G I S T R AT I O N Please fill out the enclosed warranty card to validate your purchase. All returned service items, whether under warranty or not, must be freight pre-paid and accompanied by a return authorization (R.A.) number.
  • Page 8: Safety Guidelines

    S A F E T Y G U I D E L I N E S PROTECTION CLASS 1 - FIXTURE MUST BE PROPERLY GROUNDED. THERE ARE NO USER SERVICEABLE PARTS INSIDE THIS UNIT. DO NOT ATTEMPT ANY REPAIRS YOURSELF, AS DOING SO WILL VOID YOUR MANUFACTURER’S WARRANTY.
  • Page 9: Overview

    LED Panel Lens/Filter Lock Omega Clamp Receiver Holes Mounting Bracket Safety Cable Attachment Point Bracket Adjustment Knob www.adj.co m DMX IN DMX OUT POWER OUT POWER IN MAX:100- 240V 10A AC100-24 0V 50/60Hz FUSE:T4A / 250V Air Valve POWER IN...
  • Page 10: Torque Settings For Screws

    ISSUES! TO CONFIRM THE IP65 INTEGRITY AFTER A PROCEDURE REQUIRING DISASSEMBLY/REASSEMBLY, TEST THE FIXTURE USING THE IP TESTER. CONTACT ADJ SERVICE FOR MORE DETAILS. CAUTION! THE USE OF PROTECTIVE GLOVES AND SAFETY GOGGLES IS STRONGLY RECOMMENDED WHILE PERFORMING THE IP PRESSURE TEST! AVOID PLACING YOUR FACE, EYES, HANDS, ETC IN CLOSE PROXIMITY TO THE FIXTURE’S LENS...
  • Page 11: Ip Test Parameters

    Following any repair or maintenance procedure that requires disassembly of the fixture, use ADJ’s IP Tester to confirm the IP integrity of the fixture. Please contact ADJ Service for information regarding the ADJ Hydro IP Tester, or visit the product information page online at: https://www.adj.com/hydro-ip-tester...
  • Page 12: Installation Guidelines

    I N S TA L L AT I O N G U I D E L I N E S FLAMMABLE MATERIAL WARNING Keep fixture minimum 1.6 feet (0.5m) away from flammable materials and/or pyrotechnics. ELECTRICAL CONNECTIONS A qualified electrician should be used for all electrical connections and/or installations. MINIMUM DISTANCE TO OBJECTS/SURFACES IS 1.0 FEET (0.3 METERS).
  • Page 13: Clamp Installation

    I N S TA L L AT I O N G U I D E L I N E S CLAMP INSTALLATION This fixture features an adjustable bracket for the attachment of a Mounting Clamp (not included). There is also a safety cable attachment point on the rear of the fixture. When mounting the fixture to a truss or any other suspended or overhead installation, be sure to secure appropriately rated clamp (not included) to the yoke, and attach a separate SAFETY CABLE of the appropriate weight rating to the safety cable attachment point.
  • Page 14 I N S TA L L AT I O N G U I D E L I N E S OMEGA BRACKETS INSTALLATION Secure the Mounting Clamp (not included) to the Omega Bracket (not included), then insert the Omega Bracket Assembly into the matching holes on either the Mounting Bracket, or the rear panel of the Fixture.
  • Page 15 I N S TA L L AT I O N G U I D E L I N E S RIGGING Overhead rigging requires extensive experience, including among others, calculating working load limits, installation material being used, and periodic safety inspection of all installation material and the fixture.
  • Page 16 LEDs. This issue is not specific only to ADJ lighting fixtures, but rather it is a common issue with lighting fixtures from all manufacturers. Although there is no true way to fully prevent this issue from happening, the guidelines below can reduce the risk of potential damage.
  • Page 17: Accessory Installation

    A C C E S S O R Y I N S TA L L AT I O N : L E N S Locate Lens Lock and press down to unlock it. Carefully slide Lens into the Lens Slots. Once in place, secure the Lens by pressing upwards to relock it.
  • Page 18 A C C E S S O R Y I N S TA L L AT I O N : L I G H T S H I E L D To install the Light Shield, position it at the front of the fixture and insert it into the installation frame of the Light Shield.
  • Page 19 A C C E S S O R Y I N S TA L L AT I O N : B A R N D O O R To install the Barndoor, position it at the front of the fixture and insert it inside the frame of the Barndoor.
  • Page 20: Wireless Operation

    W I R E L E S S O P E R AT I O N To set up wireless control, follow the steps below: 1. Navigate to Personality > Select Signal > Aria. 2. Navigate to Personality > Aria > Aria Enable > Select ON. 3.
  • Page 21: Fan Modes And Low Noise Operation

    FA N M O D E S a n d L O W N O I S E O P E R AT I O N The 40 Hex Panel IP is a high-performance fixture suited for multiple applications. For noise critical environments such as Theater, Opera or Orchestra Halls, it offers various fan operation modes which remove any distraction for the audience and performers.
  • Page 22: System Menu

    S Y S T E M M E N U The fixture includes an easy to navigate system menu control panel display where all necessary settings and adjustments are made. • MENU: Leave current menu and return to previous menu level. •...
  • Page 23 S Y S T E M M E N U MAIN MENU OPTIONS / VALUES (Default Settings in BOLD) 001-512 DMX Address 6Ch 1G, 12Ch 1G, 15Ch 1G, 16Ch 1G, 24Ch 1G, 12Ch 2G, 20Ch 2G, 24Ch 2G, 27Ch 2G, 29Ch 2G, 36Ch 2G, 30Ch 5G, 40Ch 5G, DMX Channel Mode SETTINGS 60Ch 5G, 63Ch 5G, 68Ch 5G, 72Ch 5G, 60Ch 10G, 70Ch 10G,...
  • Page 24 S Y S T E M M E N U MAIN MENU OPTIONS / VALUES (Default Settings in BOLD) 000 - 255 Red 000-255 Green 000-255 000 - 255 Blue 000-255 000 - 255 Amber 000-255 000 - 255 Lime 000-255 000 - 255 000 - 255 UV 000-255...
  • Page 25 D I M M E R M O D E S & C U R V E S DIMMER 100% Time (ms) 0 Sec Rise Time Down Time 0 sec Fade Time 1 sec Fade Time Dimming Curve Ramp Effect Rise Time (ms) Down Time (ms) Rise Time (ms) Down Time (ms) Standard (default) Stage...
  • Page 26: P R I M A R Y- S E C O N D A R Y S E T U P

    P R I M A R Y- S E C O N D A R Y S E T U P This function allows you to link units together to run in a Primary-Secondary set-up, in which one unit will act as the controlling unit and the others will react to the controlling unit’s built-in programs. Any unit can be configured to act as a Primary or as a Secondary, but only one unit in a given system can be programmed to act as the Primary.
  • Page 27: D M X S E T U P

    D M X S E T U P DMX-512: DMX is short for Digital Multiplex. This is a universal protocol used as a form of communication between intelligent fixtures and controllers. A DMX controller sends DMX data instructions from the controller to the fixture. DMX data is sent as serial data that travels from fixture to fixture via the DATA “IN”...
  • Page 28: Dmx Addressing

    2 and 3 of a male XLR connector (DATA + and DATA -). This unit is inserted in the female XLR connector of the last unit in your daisy chain to terminate the line. Using a cable terminator (ADJ part number DMX T Pack) will reduce the risk of erratic behavior. DMX ADDRESSING.
  • Page 29 D M X T R A I T S - 1 G R O U P CHANNEL FUNCTION 12Ch 20Ch 24Ch VALUES 15Ch 16Ch 0-255 All Red, 0~100% All Red Fine 16-Bit 0-255 0-255 All Green, 0~100% All Green Fine 16-Bit 0-255 0-255 All Blue, 0~100%...
  • Page 30 D M X T R A I T S - 1 G R O U P CHANNEL FUNCTION 12Ch 20Ch 24Ch VALUES 15Ch 16Ch All Red 10, 0~100% 0-255 0-255 All Red 10 Fine 16-Bit All Green 10, 0~100% 0-255 All Green 10 Fine 16-Bit 0-255 All Blue 10, 0~100%...
  • Page 31 D M X T R A I T S - 1 G R O U P CHANNEL FUNCTION 12Ch 20Ch 24Ch VALUES 15Ch 16Ch Internal Programs: 000-010 Off 011-026 Program 1 027-043 Program 2 044-060 Program 3 061-076 Program 4 077-093 Program 5 094-110 Program 6 111-126 Program 7...
  • Page 32 D M X T R A I T S - 1 G R O U P CHANNEL FUNCTION 12Ch 20Ch 24Ch VALUES 15Ch 16Ch Special Functions 0-15 Default to Unit Setting 16-30 900HZ 31-45 1000HZ 46-60 1100HZ 61-75 1200HZ 76-90 1300HZ 91-105 1400HZ...
  • Page 33 D M X T R A I T S - 2 G R O U P S CHANNEL FUNCTION 12Ch 20Ch 24Ch VALUES 27Ch 29Ch 36Ch 0-255 All Red, 0~100% All Red Fine 16-Bit 0-255 0-255 All Green, 0~100% All Green Fine 16-Bit 0-255 0-255 All Blue, 0~100%...
  • Page 34 D M X T R A I T S - 2 G R O U P S CHANNEL FUNCTION 12Ch 20Ch 24Ch VALUES 27Ch 29Ch 36Ch All Red 10, 0~100% 0-255 0-255 All Red 10 Fine 16-Bit All Green 10, 0~100% 0-255 All Green 10 Fine 16-Bit 0-255...
  • Page 35 D M X T R A I T S - 2 G R O U P S CHANNEL FUNCTION 12Ch 20Ch 24Ch VALUES 27Ch 29Ch 36Ch Internal Programs: 000-010 Off 011-026 Program 1 027-043 Program 2 044-060 Program 3 061-076 Program 4 077-093 Program 5 094-110 Program 6 111-126 Program 7...
  • Page 36 D M X T R A I T S - 2 G R O U P S CHANNEL FUNCTION 12Ch 20Ch 24Ch VALUES 27Ch 29Ch 36Ch Special Functions 0-15 Default to Unit Setting 16-30 900HZ 31-45 1000HZ 46-60 1100HZ 61-75 1200HZ 76-90 1300HZ...
  • Page 37 D M X T R A I T S - 5 G R O U P S CHANNEL FUNCTION 60Ch VALUES 30Ch 40Ch 63Ch 68Ch 72Ch 0-255 All Red, 0~100% All Red Fine 16-Bit 0-255 0-255 All Green, 0~100% All Green Fine 16-Bit 0-255 0-255 All Blue, 0~100%...
  • Page 38 D M X T R A I T S - 5 G R O U P S CHANNEL FUNCTION 60Ch VALUES 30Ch 40Ch 63Ch 68Ch 72Ch All Red 10, 0~100% 0-255 0-255 All Red 10 Fine 16-Bit All Green 10, 0~100% 0-255 All Green 10 Fine 16-Bit 0-255...
  • Page 39 D M X T R A I T S - 5 G R O U P S CHANNEL FUNCTION 60Ch VALUES 30Ch 40Ch 63Ch 68Ch 72Ch Internal Programs: 000-010 Off 011-026 Program 1 027-043 Program 2 044-060 Program 3 061-076 Program 4 077-093 Program 5 094-110 Program 6 111-126 Program 7...
  • Page 40 D M X T R A I T S - 5 G R O U P S CHANNEL FUNCTION 60Ch VALUES 30Ch 40Ch 63Ch 68Ch 72Ch Special Functions 0-15 Default to Unit Setting 16-30 900HZ 31-45 1000HZ 46-60 1100HZ 61-75 1200HZ 76-90 1300HZ...
  • Page 41 D M X T R A I T S - 1 0 G R O U P S CHANNEL FUNCTION 60Ch VALUES 70Ch 120Ch 123Ch 128Ch 132Ch 0-255 All Red, 0~100% All Red Fine 16-Bit 0-255 0-255 All Green, 0~100% All Green Fine 16-Bit 0-255 0-255...
  • Page 42 D M X T R A I T S - 1 0 G R O U P S CHANNEL FUNCTION 60Ch VALUES 70Ch 120Ch 123Ch 128Ch 132Ch All Red 10, 0~100% 0-255 0-255 All Red 10 Fine 16-Bit All Green 10, 0~100% 0-255 All Green 10 Fine 16-Bit 0-255...
  • Page 43 D M X T R A I T S - 1 0 G R O U P S CHANNEL FUNCTION 60Ch VALUES 70Ch 120Ch 123Ch 128Ch 132Ch Internal Programs: 000-010 Off 011-026 Program 1 027-043 Program 2 044-060 Program 3 061-076 Program 4 077-093 Program 5 094-110 Program 6...
  • Page 44 D M X T R A I T S - 1 0 G R O U P S CHANNEL FUNCTION 60Ch VALUES 70Ch 120Ch 123Ch 128Ch 132Ch Special Functions 0-15 Default to Unit Setting 16-30 900HZ 31-45 1000HZ 46-60 1100HZ 61-75 1200HZ 76-90...
  • Page 45: Red Green Blue

    C O L O R M A C R O S VALUE DMX VALUE GREEN BLUE AMBER LIME Color Macro 1 Color Macro 2 Color Macro 3 9-12 Color Macro 4 13-16 Color Macro 5 17-20 Color Macro 6 21-24 Color Macro 7 25-28 Color Macro 8...
  • Page 46 C O L O R M A C R O S VALUE DMX VALUE GREEN BLUE AMBER LIME Color Macro 33 129-132 Color Macro 34 133-136 Color Macro 35 137-140 Color Macro 36 141-144 Color Macro 37 145-148 Color Macro 38 149-152 Color Macro 39 153-156...
  • Page 47 P I X E L G R O U P S & P I X E L F L I P 2 Groups 5 Groups 10 Groups...
  • Page 48: R E M O T E D E V I C E M A N A G E M E N T ( R D M )

    R E M O T E D E V I C E M A N A G E M E N T ( R D M ) NOTE: In order for RDM to work properly, RDM enabled equipment must be used throughout the entire system, including DMX data splitters and wireless systems.
  • Page 49: Maintenance

    Regular inspections are recommended to ensure proper function and extended life. There are no user serviceable parts inside this fixture. Please refer all other service issues to an authorized ADJ service technician. Should you need any spare parts, please order genuine parts from your local ADJ dealer.
  • Page 50: Error Codes

    E R R O R C O D E S Note: Error Codes are subject to change without any prior written notice. ERROR CODES DESCRIPTION Temp Error This message will appear after a fixture reset if there is a Temperature Error or Fan Error Fan Error...
  • Page 51: Specifications

    Features: • JPFXBLKF (Sku: JPF001 - Black Filter for Jolt • IP65 rated – protects from dust, sand, moister, Panel FX, Jolt Panel FXIP and 40 HEX Panel IP) water • JPFX1X60LF (Sku: JPF014 - 1x60° Linear Effect • Aria X2 Management System Filter for Jolt Panel FX, Jolt Panel FXIP and 40 •...
  • Page 52: Dimensional Drawings

    D I M E N S I O N A L D R AW I N G S Ø0.5in. [Ø13mm] 7.1in. [180mm] 10.0in. [255mm] 1.6in. [41mm] 11.7in. [297mm] 5.5in. [141mm] 14.8in. [376mm] 6.7in. [171mm] 6.1in. [156mm] 6.2in. [159mm] 16.4in. [417mm] 3.8in.
  • Page 53: Optional Accessories

    40 HEX Panel IP Sku: JPF014 - 1x60° Linear Effect Filter for Jolt Panel FX, Jolt JPFX1X60LF Panel FXIP and 40 HEX Panel IP Sku: JPF027 - 60X1° Linear Effect Filter for Jolt Panel FX, Jolt JPFX60X1LF Panel FXIP and 40 HEX Panel IP...