Siemens Healthineers syngo.via Product Release Information

Advertisement

syngo .via
syngo .Breast Care
Release Information –
VB30A
siemens-healthineers.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the syngo.via and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Siemens Healthineers syngo.via

  • Page 1 syngo .via syngo .Breast Care Release Information – VB30A siemens-healthineers.com...
  • Page 3 syngo .via syngo .Breast Care Release Information – VB30A...
  • Page 4 Legend Version This Operator Manual applies to syngo .via Software Version VB30 syngo .Breast Care Software Version VC50 The currently installed software version is mentioned in the regulatory section of the About Box. Usability BEFORE USING THIS SYSTEM This system should be used only by employees adequately trained in the use of this equipment.
  • Page 5 Legend CAUTION Used with the safety alert symbol, indicates a hazardous situation which, if not avoided, could result in minor or moderate injury or material damage. CAUTION consists of the following elements: • Information about the nature of a hazardous situation •...
  • Page 6 Legend syngo .Breast Care | Release Information Print No. XP-VIAG.623.22.01.02...
  • Page 7: Table Of Contents

    Table of contents syngo .Breast Care 1 Release Information syngo .Breast 2 Further information about Care syngo .Breast Care Operating and configuring Legal information 3 Known issues syngo .Breast Care Configuration of Reading mammograms syngo .via | VB30A Print No. XP-VIAG.623.22.01.02...
  • Page 8 Table of contents syngo .Breast Care | Release Information Print No. XP-VIAG.623.22.01.02...
  • Page 9: Release Information

    syngo .Breast Care 1 Release Information Release Information syngo .Breast Care syngo .Breast Care, the soft copy review environment for Welcome to both screening and diagnostic mammography as well as digital breast tomosynthesis. We would appreciate your feedback regarding this software version. If you have any suggestions for future improvements, please forward them to your local Siemens representative.
  • Page 10 syngo .Breast Care 1 Release Information syngo .Breast Care | Release Information Print No. XP-VIAG.623.22.01.02...
  • Page 11: Further Information About

    syngo .Breast Care 2 Further information about Further information about syngo .Breast Care syngo .Breast Care Operating and configuring syngo .Breast Care Operator Manual gives you an overview on Operator Manual syngo .Breast the most important tools that are available in your Care system.
  • Page 12 syngo .Breast Care 2 Further information about syngo .Breast Care | Release Information Print No. XP-VIAG.623.22.01.02...
  • Page 13: Care

    Known issues 3 Known issues syngo .Breast Care Configuration of Important Information for system configuration: To ensure proper performance and avoid errors when working with syngo .Breast Care, your IT Administrator should set the Windows system environment variable “FORCE_FEDATYPE=OpenGL” by using of different graphic cards.
  • Page 14 3 Known issues Images printed in wrong size When selecting a single image for printing in the overview and printing it via the print workflow step, the image may be printed in a wrong size.  Please make sure to use the True Size or Fit to Segment sizing modes within the print workflow step.
  • Page 15 Known issues 3 Link Views does not work for Link Views and automatic nipple detection require the so called images without pixel padding "pixel padding" information in the DICOM image. Most MG images provide this information. If upon grayscale inversion the background of the image stays black, this information is provided and Link Views can be used.
  • Page 16 3 Known issues Modifications are not kept for When you pan images in an tomosynthesis layout, then save and re- tomo images open the case the images are not displayed at the modified position. They are always realigned and do not keep the last position. Incomplete image overlay on When tomosynthesis images are displayed in small segments, it tomo images...
  • Page 17 Known issues 3 Ultrasound (US) scrolling - While scrolling trough US images in US layout, the scroll bar does scroll bar is not moving till the not move to the bottom last position. All datasets will be displayed. end position Structured Roaming is not In case Structured Roaming is used in combination with tomo applied for tomo data sets...
  • Page 18 3 Known issues Thumbnails in Series Navigator In the Series Navigator all available objects of a patient are represented as thumbnails with text labels. The thumbnails contain the images in standard orientation, but the icons do not always adapt to dorsal/ventral setting. No target position displayed Using the tomo biopsy layout, no target position is currently displayed for Tomo Scout and stereo datasets.
  • Page 20 The CE marking applies only to medical devices which have been put on the market according to the above-mentioned EC Directive. Unauthorized changes to this product invalidate this declaration. Manufacturer’s note: Whenever the hardware necessary to run the software is This product is provided with a CE marking in accordance with supplied, the CE Mark is provided in accordance with, if the regulations stated in Appendix II of the Directive 93/42/EEC...