Siemens Healthineers MULTIX Impact E Operator's Manual

Hide thumbs Also See for MULTIX Impact E:

Advertisement

MULTIX Impact E
Operator Manual – Customer Self Service Book
siemens-healthineers.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MULTIX Impact E and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Siemens Healthineers MULTIX Impact E

  • Page 1 MULTIX Impact E   Operator Manual – Customer Self Service Book siemens-healthineers.com...
  • Page 2: Table Of Contents

    Table of contents Replacement Replacement of keyboard, mouse, DVD-W ROW and barcode reader Replacement of detector battery charger Replacement of hand switch for radiation release Customer Self Service Book | Operator Manual MULTIX Impact E Print No. XPB2-200G.621.11.02.02...
  • Page 3: Replacement

    • Hand switch for radiation release (optional) You can also replace the following parts as required before examinations: • Detector battery For the details about the detector battery replacement, refer to the MULTIX Impact E Operator Manual. Tool: Cross screwdriver...
  • Page 4: Replacement Of Detector Battery Charger

    Green LED is illuminated when power is on. ✓ Switch off the system and turn off the main power supply. 1 Unplug the power cable from the damaged battery charger. Customer Self Service Book | Operator Manual MULTIX Impact E Print No. XPB2-200G.621.11.02.02...
  • Page 5: Replacement Of Hand Switch For Radiation Release

    (1) Hand switch (optional) (2) Emergency STOP button (3) Generator ON/OFF console For more details about the Generator ON/OFF console, refer to the MULTIX Impact E Operator Manual. ✓ Switch off the system and turn off the main power supply.
  • Page 6 7 Connect the system to the main power supply and switch on the system. Make sure that the Emergency STOP button is not pressed. If it has been pressed, turn the button clockwise to disengage it. Customer Self Service Book | Operator Manual MULTIX Impact E Print No. XPB2-200G.621.11.02.02...
  • Page 7: Customer Self Service Book | Operator Manual Multix Impact E

    1 Replacement 8 Perform a functional test of the new hand switch by releasing an exposure. Customer Self Service Book | Operator Manual MULTIX Impact E Print No. XPB2-200G.621.11.02.02...
  • Page 8 This document is maintained in electronic form through Siemens Healthineers distribution channels. Printed versions not provided by Siemens Healthineers and/or downloaded copies are considered uncontrolled. Original language: English Siemens Healthineers Headquarters Manufacturer EU Authorized Representative Siemens Shanghai Medical Equipment Siemens Healthineers AG Siemens Healthcare GmbH Ltd.

Table of Contents