Aqueon QuietFlow 10, 20, 40, 60, 100 Manual

Aqueon QuietFlow 10, 20, 40, 60, 100 Manual

  • Also fits for
  • Quietflow 20
  • Quietflow 40
  • Quietflow 60
  • Quietflow 100
  • 06995
  • 06996
  • 06997
  • 06998
  • 06999

Advertisement

Aqueon QuietFlow 10, 20, 40, 60, 100 Manual

Installation Instructions

  1. Check air pump for any signs of shipping damage. If damaged, do not operate and return to place of purchase.
  2. Place Air Pump on flat surface near aquarium.
  3. Connect one end of the airline tubing (sold separately) to air outlet valves on the back of the unit, then secure tubing with braces, connect the other end of the airline tubing to décor.(Please note: For the 60G and 100G units, TWO separate airline tubes should be attached, simply repeat the step above.)
  4. Be sure that the cord makes a "drip loop" to prevent water from running down and into the air pump plug or receptacle.
  5. Plug in air pump.

Product Specifications

Model Number Aqueon ® Air Pumps Recommended Aquarium Size Wattage Voltage
06995 Model 10 2-10 gallon 1.5 W 120V/60Hz
06996 Model 20 11-20 gallon 1.7 W 120V/60Hz
06997 Model 40 40 gallon and under 2.8 W 120V/60Hz
06998 Model 60 60 gallon and under 3.2 W 120V/60Hz
06999 Model 100 100 gallon and under 3.8 W 120V/60Hz

Maintenance

To maintain efficient performance of the Air Pump, replacing worn internal rubber diaphragms, check valve(s) and dirty filter pads (sold separately in repair/replacement kits) is recommended.

Kits Includes
Aqueon ® QuietFlow ® Air Pump Model Size Check Valve(s) Filter Diaphragms
Model 10 1 1 1
Model 20 1 1 1
Model 40 1 1 1
Model 60 2 1 2
Model 100 2 1 2

IMPORTANT SAFETY INSTRUCTIONS


To guard against injury, basic safety precautions should be observed including the following:

READ AND FOLLOW ALL SAFETY INSTRUCTIONS

To avoid possible electric shock, special care should be taken since water is employed in the use of aquarium equipment. For each of the following situations, return the appliance to an authorized service facility for service or discard the appliance.

    1. If the appliance shows any sign of abnormal water leakage, immediately unplug it from the power source.
    2. Carefully examine the appliance after installation. It should not be plugged in if there is water on the parts not intended to be wet.
    3. Do not operate any appliance if it has a damaged cord or plug, or if it is malfunctioning or if it is dropped or damaged in any manner.
    4. To avoid the possibility of the appliance plug or receptacle getting wet, position aquarium stand and tank to one side of the wall mounted receptacle to prevent water from dripping onto the receptacle or plug. As shown in the figure below, a "drip loop" should be arranged by the user for each cord connecting an aquarium appliance to the receptacle. The "drip loop" is the part of the cord below the level of the receptacle, or the connector if an extension cord is used, t o prevent water travel along the cord and coming in contact with the receptacle. If the plug or the receptacles do get wet, DON'T unplug the cord. D isconnect the fuse to the circuit breaker that s upplies power to the appliance. Then unplug and examine for the presence of water in t he receptacle.
  1. Close supervision is necessary when any appliance i s used by or near children.
  2. To avoid injury, do not contact moving parts or h ot parts such as heaters, reflectors, lamp bulbs, etc.
  3. Always unplug an appliance from the outlet when n ot in use, before putting on or taking off parts, and before cleaning. Never yank the cord to pull plug from the outlet. Grasp the plug and pull t o disconnect.
  4. Do not use an appliance for other than intended use. The use of attachments not recommended or sold by the appliance manufacturer may cause an unsafe condition.
  5. Do not install or store the appliance where it will be exposed to the weather or to temperatures below freezing.
  6. Make sure an appliance mounted on a tank is securely installed before operating it.
  7. Read and observe all the important notices on the appliance.
  8. If an extension cord is necessary, a cord with a proper rating should be used. A cord rated for less amperesor watts than the appliance rating may overheat. Care should be taken to arrange the cord so that it will not be tripped over or pulled.

ONLY FOR POLARIZED ATTACHMENT PLUG APPLIANCES

  1. If this appliance has a polarized plug (one blade is wider than the other) as a safety feature, this plug will fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician. Never use with an extension cord unless plug can be fully inserted. Do not attempt to defeat this safety feature.

SAVE THESE INSTRUCTIONS

Documents / Resources

Download manual

Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.

Download Aqueon QuietFlow 10, 20, 40, 60, 100 Manual

Advertisement

Need help?

Need help?

Do you have a question about the QuietFlow 10 and is the answer not in the manual?

Questions and answers

Table of Contents