Download Print this page

Advertisement

Quick Links

Instruction Manual
TMS809 AGP 3.0 Bus Support
071-1084-00
Warning
The servicing instructions are for use by qualified
personnel only. To avoid personal injury, do not
perform any servicing unless you are qualified to
do so. Refer to all safety summaries prior to
performing service.
www.tektronix.com

Advertisement

loading
Need help?

Need help?

Do you have a question about the TMS809 and is the answer not in the manual?

Questions and answers

Summary of Contents for Tektronix TMS809

  • Page 1 Instruction Manual TMS809 AGP 3.0 Bus Support 071-1084-00 Warning The servicing instructions are for use by qualified personnel only. To avoid personal injury, do not perform any servicing unless you are qualified to do so. Refer to all safety summaries prior to performing service.
  • Page 2 Copyright © Tektronix, Inc. All rights reserved. Licensed software products are owned by Tektronix or its suppliers and are protected by United States copyright laws and international treaty provisions. Use, duplication, or disclosure by the Government is subject to restrictions as set forth in subparagraph (c)(1)(ii) of the Rights in Technical Data and Computer Software clause at DFARS 252.227-7013, or subparagraphs (c)(1) and (2) of the...
  • Page 3 In order to obtain service under this warranty, Customer must notify Tektronix of the defect before the expiration of the warranty period. If Tektronix is unable to provide a replacement that is free from defects in materials and workmanship within a reasonable time thereafter, Customer may terminate the license for this software product and return this software product and any associated materials for credit or refund.
  • Page 4 Tektronix, with shipping charges prepaid. Tektronix shall pay for the return of the product to Customer if the shipment is to a location within the country in which the Tektronix service center is located. Customer shall be responsible for paying all shipping charges, duties, taxes, and any other charges for products returned to any other locations.
  • Page 5 ........5- - 3 TMS809 AGP 3.0 Bus Support...
  • Page 6 ........6- - 2 Index TMS809 AGP 3.0 Bus Support...
  • Page 7: Table Of Contents

    ......5- -9 Figure 6- -1: Interposer probe head exploded view ....6- -4 TMS809 AGP 3.0 Bus Support...
  • Page 8 ....6- -6 Figure 6- -3: Preprocessor unit exploded view ....6- -9 TMS809 AGP 3.0 Bus Support...
  • Page 9: List Of Tables

    ....3- -23 Table 3- -32: Misc channel group definitions ....3- -23 TMS809 AGP 3.0 Bus Support...
  • Page 10 ..... . 4- -3 Table 4- -5: Certifications and compliances ....4- -5 TMS809 AGP 3.0 Bus Support...
  • Page 11: General Safety Summary

    Do Not Operate in Wet/Damp Conditions. Do Not Operate in an Explosive Atmosphere. Keep Product Surfaces Clean and Dry. Provide Proper Ventilation. Refer to the manual’s installation instructions for details on installing the product so it has proper ventilation. TMS809 AGP 3.0 Bus Support...
  • Page 12 WARNING indicates an injury hazard not immediately accessible as you read the marking. CAUTION indicates a hazard to property including the product. CAUTION WARNING Protective Ground Mains Connected Mains Disconnected Refer to Manual High Voltage (Earth) Terminal ON (Power) OFF (Power) TMS809 AGP 3.0 Bus Support viii...
  • Page 13: Service Safety Summary

    Use Care When Servicing With Power On. Dangerous voltages or currents may exist in this product. Disconnect power, remove battery (if applicable), and disconnect test leads before removing protective panels, soldering, or replacing components. To avoid electric shock, do not touch exposed connections. TMS809 AGP 3.0 Bus Support...
  • Page 14 Service Safety Summary TMS809 AGP 3.0 Bus Support...
  • Page 15: Manual Conventions

    Preface This instruction manual contains specific information about the TMS809 AGP 3.0 Bus support package and is part of a set of information on how to operate this product on compatible Tektronix logic analyzers. If you are familiar with operating bus support packages on the logic analyzer, you only need this instruction manual to set up and run the TMS809 support package.
  • Page 16: Contacting Tektronix

    This phone number is toll free in North America. After office hours, please leave a voice mail message. Outside North America, contact a Tektronix sales office or distributor; see the Tektronix web site for a list of offices. TMS809 AGP 3.0 Bus Support...
  • Page 17 Getting Started...
  • Page 19: Getting Started

    V3.0 Interface Specification, Revision 0.95R, original date: May 2001 document (Intel web site). Logic Analyzer Software Compatibility The label on the floppy disk states which version of logic analyzer software the probe adapter package is compatible with. TMS809 AGP 3.0 Bus Support 1- 1...
  • Page 20: Logic Analyzer Configuration

    NOTE. When using the TLA7Axx modules with the TMS809 probe adapter, the analog outputs display the outputs of the digital buffers of the TMS809 and do not directly reflect the analog attributes of the AGP bus. TMS809 AGP 3.0 Bus Support...
  • Page 21: Figure 1- -1: Configuration Of The Slave 2, Master, And

    Setup menu is also enabled (see Custom Clocking Mode on page 2- -3). To use the AGP4X mode, refer to Configuring the Probe Adapter on page 1- -6. The AGP 3.0 probe adapter is shipped configured for the AGP8X mode. TMS809 AGP 3.0 Bus Support 1- 3...
  • Page 22 Probe Adapter on page 1- -6. The probe adapter is shipped from the factory in the AGP8X mode configuration. Nonintrusive Acquisition. The probe adapter will not present signals back to the target system. TMS809 AGP 3.0 Bus Support 1- 4...
  • Page 23 H Document and software package: Includes the probe adapter manual, license agreement envelope with software disc, registration card, and statement of compliance envelope For optional accessories, see the Replaceable Parts List on page 6- -8. TMS809 AGP 3.0 Bus Support 1- 5...
  • Page 24: Configuring The Probe Adapter

    NOTE. The AGP4X mode is available only for AGP3.0 target systems. 8X mode 4X mode The “i” indicates a reminder to reset the target system. Figure 1- 2: Switch for AGP8X or AGP4X mode TMS809 AGP 3.0 Bus Support 1- 6...
  • Page 25 There are no operator serviceable parts inside the preprocessor unit. Refer servicing of internal parts in the preprocessor unit to Tektronix authorized personnel only. External parts may be replaced by qualified service personnel. Tools Required. Following is a list of required tools:...
  • Page 26 7. Connect the AGP 3.0 bus card to the Interposer probe head. CAUTION. To prevent damage to the probe adapter or target system when power is applied, connect the target system to the probe adapter properly. TMS809 AGP 3.0 Bus Support 1- 8...
  • Page 27: Figure 1- -3: Connect The Interposer Probe Adapter To The Agp 3.0 Bus Connector

    2. Power off the target system. You do not need to power off the logic analyzer. 3. Discharge the stored static electricity by touching the ground connector located on the back of the logic analyzer. TMS809 AGP 3.0 Bus Support 1- 9...
  • Page 28: Figure 1- 4: Preprocessor Unit And Access Panel

    Yellow to - - 5 V Red to +5 V Figure 1- 5: Attach the power cables 7. Hand start the screws that attach the access panel to the top of the preproces- sor unit. TMS809 AGP 3.0 Bus Support 1- 10...
  • Page 29 Backside probe head, follow these steps: 6. Using a Phillips screwdriver, remove the two screws from the center two holes on the Front End board assembly (see Figure 1- -8 on page 1- -17). TMS809 AGP 3.0 Bus Support 1- 11...
  • Page 30 AGP 3.0 board. 4. Place the target system on a horizontal, static-free surface (the back of the AGP 3.0 connector must be visible). TMS809 AGP 3.0 Bus Support 1- 12...
  • Page 31 5. Retrieve the mounting plate and the positioning block from the supplied standard accessories (see Figure 1- -6). 6. Position the mounting plate near the top of the positioning block (see Figure 1- -6). TMS809 AGP 3.0 Bus Support 1- 13...
  • Page 32: Figure 1- 6: Attaching The Mounting Plate To The Target System

    AGP 3.0 connector (see Figure 1- -6). TMS809 AGP 3.0 Bus Support 1- 14...
  • Page 33 14. Locate the four tab holes on the Front End board assembly (the side without the heatsink). 15. Insert the four tabs on the Backside board assembly into the four tab holes on the Front End board assembly, press into place. TMS809 AGP 3.0 Bus Support 1- 15...
  • Page 34: Figure 1- 7: Attaching The Front End Board Assembly

    Backside board assembly Tabs (4) Figure 1- 7: Attaching the Front End board assembly NOTE. The two ribbon cables are captured between the two assemblies when the Backside probe head is properly installed. TMS809 AGP 3.0 Bus Support 1- 16...
  • Page 35: Figure 1- 8: Assembled Backside Probe Head

    Front End board assembly to the Backside board assembly Front End board assembly Backside board assembly Target system Mounting plate Figure 1- 8: Assembled Backside probe head TMS809 AGP 3.0 Bus Support 1- 17...
  • Page 36: Figure 1- 9: Attach The Power Cables

    A to A, B to B, and C to C, to the Logic board. Access to the small boards is through the access panel on top of the preprocessor unit (see Figure 1- -10). Screws (6) Access panel Figure 1- 10: Preprocessor unit and access panel TMS809 AGP 3.0 Bus Support 1- 18...
  • Page 37 WARNING. To prevent burns, forced air cooling is required across the probe °C °F) adapter to maintain a temperature below 105 (220 . You must verify this temperature for the components and the probe adapter. 23. Apply forced air cooling across the probe head. TMS809 AGP 3.0 Bus Support 1- 19...
  • Page 38 S2_A_DIS, S2_D_DIS, S2_C_DIS, and S2_E_DIS probe connectors labels on the preprocessor unit. Align the pin 1 indicator on the probe label with the pin 1 indicator of the connector on the preprocessor unit. TMS809 AGP 3.0 Bus Support 1- 20...
  • Page 39: Figure 1- 12: Operating The P6434 Probe Latches

    Align the pin 1 indicator on the probe label with pin 1 of the connector on the preprocessor unit (see Figure 1- -12). 7. Repeat steps 2 and 3 to correctly connect the probes. TMS809 AGP 3.0 Bus Support 1- 21...
  • Page 40: Figure 1- 13: Probes With Mictor Adapters

    Figure 1- -13 shows probes using mictor adapters with compression footprints. For more information about these probes, refer to page 1- -2. P6860 P6434 Compression adapter Mictor adapter Mictor adapter Figure 1- 13: Probes with mictor adapters TMS809 AGP 3.0 Bus Support 1- 22...
  • Page 41 There are no operator serviceable parts inside the preprocessor unit. Refer servicing of internal parts in the preprocessor unit to Tektronix authorized personnel only. External parts may be replaced by qualified service personnel. 1. Check that the power switch on the preprocessor unit is in the off position. If powered off, the zero (0) is visible on the power switch.
  • Page 42: Figure 1- 14: Preprocessor Unit And Access Panel

    H Check the probe head cable connections through the opening in the top of the preprocessor unit (see Figure 1- -14). H If the LED is still not lighted, call a Tektronix application engineer. 2. Check that signals are passing through the mictor connectors by using the following procedure: a.
  • Page 43: Figure 1- -15: Replacing The Pogo Pin Assembly On The Backside Board

    (torque to 4 in/lb) to the Backside board. Flat head Pogo pin assembly screws (2) Align holes Align 4 spiral pins to holes Backside board Figure 1- 15: Replacing the Pogo pin assembly on the Backside board TMS809 AGP 3.0 Bus Support 1- 25...
  • Page 44 When you fold the cables use a minimum radius of 0.25 (0.64 cm) at the fold. 7. Place the foam end caps on both sides of the preprocessor unit. The depression on the foam end caps is positioned up. TMS809 AGP 3.0 Bus Support 1- 26...
  • Page 45: Care And Maintenance

    To prevent static damage, handle components only in a static-free environment. The TMS809 AGP 3.0 probe adapter does not require scheduled or periodic maintenance. However, to maintain good electrical contact and efficient heat dissipation, keep the probe adapter free of dirt, dust, and contaminants. When not in use, store the probe adapter in the original shipping bags and cardboard cartons (see Storage on page 1- -26).
  • Page 46 (7.62 cm) larger on each side and top of the carton than the probe adapter. 2. If you are shipping the probe adapter to a Tektronix service center for Warranty service, attach a tag to the probe adapter showing the following: H Owner’s name and address...
  • Page 47: Operating Basics

    Operating Basics...
  • Page 49: Setting Up The Software

    Setting Up the Software This section provides information on how to set up the TMS809 AGP 3.0 Bus software on any Tektronix logic analyzer along with the following topics: H Channel group definitions and symbol table overview H Support package setups...
  • Page 50 Setting up the Software Support Package Setups The TMS809 AGP 3.0 software package installs three setup support files. Each setup provides different clocking and display options. All channels are displayed as active high. AGP3_8X Setup This setup provides disassembly support for the AGP3_8X bus.
  • Page 51: Acquiring And Viewing Disassembled Data

    Appendix A: Error Messages and Disassem- bly Problems in the logic analyzer user manual. Clocking The module acquires AGP 3.0 signals using the TMS809 AGP 3.0 bus support software and probe adapter. For correct disassembly, do not use the Internal or External clocking modes. The logic analyzer online help describes in more detail how to use these clock selections for general purpose analysis.
  • Page 52: Figure 2- 1: Select These Definitions For Agp8X

    Figure 2- -1. NOTE. When AGP4X mode is enabled the same menu definitions are selected, except channel 4X/PCI#_AD and omit groups 4- -SBA[7:0]# and 6_SBA[7:0]#. Figure 2- 1: Select these definitions for AGP8X TMS809 AGP 3.0 Bus Support 2- 4...
  • Page 53: Table 2- 1: Waveform Displays

    AD_STBS0 AD[15- - 0] AD_STBF1 AD_STBS1 AD[31- - 16] [0- - 7]_AD[31- - 0] Command SBA[7:0] [0- - 7]_SBA[7:0] SBA_STBF SBA_STBS C#_BE[3:0] [0- - 7]_C#_BE[3:0] FRAME# IRDY# TRDY# RBF# WBF# STOP# DEVSEL# REQ# TMS809 AGP 3.0 Bus Support 2- 5...
  • Page 54: Table 2- 2: Default Display Radix

    Group name 0/ SBA[7:0]# 1_SBA[7:0]# 2_SBA[7:0]# 3_SBA[7:0]# 4_SBA[7:0]# 5_SBA[7:0]# 6_SBA[7:0]# 7_SBA[7:0]# Mnemonics TEXT 0/PCI_AD[31:0] 1_AD[31:0] 2_AD[31:0] 3_AD[31:0] 4_AD[31:0] 5_AD[31:0] 6_AD[31:0] 7_AD[31:0] Addr/Data 0/PCI_C#_BE[3:0] 1_C#_BE[3:0] 2_C#_BE[3:0] 3_C#_BE[3:0] 4_C#_BE[3:0] 5_C#_BE[3:0] 6_C#_BE[3:0] 7_C#_BE[3:0] TMS809 AGP 3.0 Bus Support 2- 6...
  • Page 55: Viewing An Example Of Disassembled Data

    Viewing the system file is not a requirement for preparing the module for use and you can view it without connecting the logic analyzer to the target system. TMS809 AGP 3.0 Bus Support 2- 7...
  • Page 56 Setting up the Software TMS809 AGP 3.0 Bus Support 2- 8...
  • Page 57 Reference...
  • Page 59: Table 3- 1: Agp3_Command Symbol Table Definitions

    0000 PCI_Mem_Rd_Inv PCI Memory Write and Invali- date 110X PCI_I/O_R/W PCI Input/Output Read/Write 100X PCI_Mem_R/W PCI Memory Read/Write 010X PCI_Config_R/W PCI Configuration Read/Write XXXX PCI_Cmd Any PCI Command XXXX PCI data XXXX Reserved/Undefined TMS809 AGP 3.0 Bus Support 3- 1...
  • Page 60: Table 3- 2: Agp3_Status Symbol Table Definitions

    IRDY/TRDY Asserted XXXX XXXXX 1XXX IRDY IRDY Asserted XXXX XXXXX X1XX TRDY TRDY Asserted 1XXX XXXXX XXXX Rd_Buf_Fl Read Buffer Full XXXX X1XXX XXXX Grant Grant Asserted XXXX 1XXXX XXXX Request Request Asserted TMS809 AGP 3.0 Bus Support 3- 2...
  • Page 61 Stop Stop Asserted XXXX XXXXX XX1X Dev_Sel Device Select Asserted XXXX XX1XX XXXX Frame Frame Asserted XXXX XXXXX XXXX Pwr_Mgmt_Ev Power Management Event XXX1 XXXXX XXXX Pipe Asserted 000X 000XX 0000 Bus inactive TMS809 AGP 3.0 Bus Support 3- 3...
  • Page 62: Table 3- 4: Agp3_Sba_Cmd Symbol Table Definitions

    Returns time offset of corelogic 1011 110X Reserved - - - - - - 10XX XX1X Invalid Type 2, invalid reserved bit 0XXX XXXX Type_1 Lower address and command 1111 0XXX Reserved Reserved command TMS809 AGP 3.0 Bus Support 3- 4...
  • Page 63: Table 3- 5: 7_Ad[31:0] Channel Group Definitions

    Table 3- 5: 7_AD[31:0] channel group definitions AGP 3.0 support order channel name 7_AD31 7_AD30 7_AD29 7_AD28 7_AD27 7_AD26 7_AD25 7_AD24 7_AD23 7_AD22 7_AD21 7_AD20 7_AD19 7_AD18 TMS809 AGP 3.0 Bus Support 3- 5...
  • Page 64: Table 3- 6: 6_Ad[31:0] Channel Group Definitions

    Table 3- -6 lists the group definitions for the 6_AD[31:0] channel group. By default, this group is displayed in hexadecimal. Table 3- 6: 6_AD[31:0] channel group definitions AGP 3.0 support order channel name 6_AD31 6_AD30 6_AD29 6_AD28 6_AD27 6_AD26 6_AD25 TMS809 AGP 3.0 Bus Support 3- 6...
  • Page 65 Table 3- 6: 6_AD[31:0] channel group definitions (Cont.) AGP 3.0 support order channel name 6_AD24 6_AD23 6_AD22 6_AD21 6_AD20 6_AD19 6_AD18 6_AD17 6_AD16 6_AD15 6_AD14 6_AD13 6_AD12 6_AD11 6_AD10 6_AD9 6_AD8 6_AD7 6_AD6 6_AD5 6_AD4 6_AD3 6_AD2 6_AD1 6_AD0 TMS809 AGP 3.0 Bus Support 3- 7...
  • Page 66: Table 3- 7: 5_Ad[31:0] Channel Group Definitions

    AGP 3.0 support order channel name 5_AD31 5_AD30 5_AD29 5_AD28 5_AD27 5_AD26 5_AD25 5_AD24 5_AD23 5_AD22 5_AD21 5_AD20 5_AD19 5_AD18 5_AD17 5_AD16 5_AD15 5_AD14 5_AD13 5_AD12 5_AD11 5_AD10 5_AD9 5_AD8 5_AD7 5_AD6 5_AD5 5_AD4 5_AD3 TMS809 AGP 3.0 Bus Support 3- 8...
  • Page 67: Table 3- 8: 4_Ad[31:0] Channel Group Definitions

    Table 3- 8: 4_AD[31:0] channel group definitions AGP 3.0 support order channel name 4_AD31 4_AD30 4_AD29 4_AD28 4_AD27 4_AD26 4_AD25 4_AD24 4_AD23 4_AD22 4_AD21 4_AD20 4_AD19 4_AD18 4_AD17 4_AD16 4_AD15 4_AD14 4_AD13 4_AD12 4_AD11 4_AD10 TMS809 AGP 3.0 Bus Support 3- 9...
  • Page 68: Table 3- 9: 3_Ad[31:0] Channel Group Definitions

    Table 3- 9: 3_AD[31:0] channel group definitions AGP 3.0 support order channel name 2_AD31 2_AD30 2_AD29 2_AD28 2_AD27 2_AD26 2_AD25 2_AD24 2_AD23 2_AD22 2_AD21 2_AD20 2_AD19 2_AD18 2_AD17 TMS809 AGP 3.0 Bus Support 3- 10...
  • Page 69: Table 3- 10: 2_Ad[31:0] Channel Group Definitions

    Table 3- -10 lists the group definitions for the 2_AD[31:0] channel group. By default, this group is displayed in hexadecimal. Table 3- 10: 2_AD[31:0] channel group definitions AGP 3.0 support order channel name 3_AD31 3_AD30 3_AD29 3_AD28 3_AD27 3_AD26 3_AD25 3_AD24 TMS809 AGP 3.0 Bus Support 3- 11...
  • Page 70 Table 3- 10: 2_AD[31:0] channel group definitions (Cont.) AGP 3.0 support order channel name 3_AD23 3_AD22 3_AD21 3_AD20 3_AD19 3_AD18 3_AD17 3_AD16 3_AD15 3_AD14 3_AD13 3_AD12 3_AD11 3_AD10 3_AD9 3_AD8 3_AD7 3_AD6 3_AD5 3_AD4 3_AD3 3_AD2 3_AD1 3_AD0 TMS809 AGP 3.0 Bus Support 3- 12...
  • Page 71: Table 3- 11: 1_Ad[31:0] Channel Group Definitions

    AGP 3.0 support order channel name 1_AD31 1_AD30 1_AD29 1_AD28 1_AD27 1_AD26 1_AD25 1_AD24 1_AD23 1_AD22 1_AD21 1_AD20 1_AD19 1_AD18 1_AD17 1_AD16 1_AD15 1_AD14 1_AD13 1_AD12 1_AD11 1_AD10 1_AD9 1_AD8 1_AD7 1_AD6 1_AD5 1_AD4 1_AD3 TMS809 AGP 3.0 Bus Support 3- 13...
  • Page 72: Table 3- 12: 0/Pci_Ad[31] Channel Group Definitions

    Table 3- 12: 0/PCI_AD[31] channel group definitions AGP 3.0 support order channel name 0/PCI_AD31 0/PCI_AD30 0/PCI_AD29 0/PCI_AD28 0/PCI_AD27 0/PCI_AD26 0/PCI_AD25 0/PCI_AD24 0/PCI_AD23 0/PCI_AD22 0/PCI_AD21 0/PCI_AD20 0/PCI_AD19 0/PCI_AD18 0/PCI_AD17 0/PCI_AD16 0/PCI_AD15 0/PCI_AD14 0/PCI_AD13 0/PCI_AD12 0/PCI_AD11 0/PCI_AD10 TMS809 AGP 3.0 Bus Support 3- 14...
  • Page 73: Table 3- 14: 6_C#_Be[3:0]Channel Group Definitions

    Table 3- -14 lists the group definitions for the 6_C#_BE[3:0] channel group. By default, this group is displayed in hexadecimal. Table 3- 14: 6_C#_BE[3:0]channel group definitions AGP 3.0 support order channel name 6_C#_BE3 6_C#_BE2 6_C#_BE1 6_C#_BE0 TMS809 AGP 3.0 Bus Support 3- 15...
  • Page 74: Table 3- 17: 3_C#_Be[3:0]Channel Group Definitions

    Table 3- -17 lists the group definitions for the 3_C#_BE[3:0] channel group. By default, this group is displayed in hexadecimal. Table 3- 17: 3_C#_BE[3:0]channel group definitions AGP 3.0 support order channel name 3_C#_BE3 3_C#_BE2 3_C#_BE1 3_C#_BE0 TMS809 AGP 3.0 Bus Support 3- 16...
  • Page 75: Table 3- 19: 1_C#_Be[3:0] Channel Group Definitions

    Table 3- -20 lists the group definitions for the 0/PCI_C#_BE[3:0] channel group. By default, this group is displayed in hexadecimal. Table 3- 20: 0/PCI_C#_BE[3:0] channel group definitions AGP 3.0 support Order channel name 0 _C#_BE3 0_C#_BE2 0_C#_BE1 0_C#_BE0 TMS809 AGP 3.0 Bus Support 3- 17...
  • Page 76: Table 3- 22: 6_Sba[7:0]# Channel Group Definitions

    AGP3 _SBA_Cmd. By default, this group is displayed as symbols. Table 3- 22: 6_SBA[7:0]# channel group definitions AGP 3.0 support order channel name 6_SBA7 6_SBA6 6_SBA5 6_SBA4 6_SBA3 6_SBA2 6_SBA1 6_SBA0 TMS809 AGP 3.0 Bus Support 3- 18...
  • Page 77: Table 3- 24: 4_Sba[7:0]# Channel Group Definitions

    AGP3 _SBA_Cmd. By default, this group is displayed as symbols. Table 3- 24: 4_SBA[7:0]# channel group definitions AGP 3.0 support order channel name 4_SBA7 4_SBA6 4_SBA5 4_SBA4 4_SBA3 4_SBA2 4_SBA1 4_SBA0 TMS809 AGP 3.0 Bus Support 3- 19...
  • Page 78: Table 3- 26: 2_Sba[7:0]# Channel Group Definitions

    AGP3 _SBA_Cmd. By default, this group is displayed as symbols. Table 3- 26: 2_SBA[7:0]# channel group definitions AGP 3.0 support order channel name 2_SBA7 2_SBA6 2_SBA5 2_SBA4 2_SBA3 2_SBA2 2_SBA1 2_SBA0 TMS809 AGP 3.0 Bus Support 3- 20...
  • Page 79: Table 3- 27: 1_Sba[7:0]# Channel Group Definitions

    The symbol table file name is AGP3 _SBA_Cmd. By default, this group is displayed as symbols. Table 3- 28: 0/PCI_SBA[7:0]# channel group definitions AGP 3.0 support order channel name 0_SBA7 0_SBA6 0_SBA5 0_SBA4 0_SBA3 0_SBA2 0_SBA1 0_SBA0 TMS809 AGP 3.0 Bus Support 3- 21...
  • Page 80: Table 3- 29: Command Channel Group Definitions

    AGP3_Control. By default, this group is displayed as symbols. Table 3- 30: Control channel group definitions AGP 3.0 support order channel name RESET# PME# SERR PERR FRAME FRAME_L IRDY TRDY DEVSEL STOP TMS809 AGP 3.0 Bus Support 3- 22...
  • Page 81: Table 3- 31: Status Channel Group Definitions

    Table 3- -32 lists the group definitions for the Misc channel group. By default, this group is displayed as hexadecimal. Table 3- 32: Misc channel group definitions AGP 3.0 support order channel name PCI_DBI_HI# PCI_DBI_LO# OVRCNT# INTA# INTB# TMS809 AGP 3.0 Bus Support 3- 23...
  • Page 82 Channel Group Definition Tables TMS809 AGP 3.0 Bus Support 3- 24...
  • Page 83: Channel Assignment Tables

    The term slave 2 module refers to the module in the lower numbered slot than the master module. Slave 2 Master Slave Figure 3- 1: Configuration for slave 2, master, and slave modules TMS809 AGP 3.0 Bus Support 3- 25...
  • Page 84 AGP3_T support acquisition channel name channel name channel Clock:0 - - - - - - QUAL:1 FRAME_L AD_STBF1 QUAL:2 Q_RESET# - - - - - - S2_QUAL:0 IRDY - - - - - - TMS809 AGP 3.0 Bus Support 3- 26...
  • Page 85 A2:1 5_AD17 PERR A2:2 5_AD18 C#_BE2 A2:3 5_AD19 A2:4 5_AD20 A2:5 5_AD21 A2:6 5_AD22 - - - - - - A2:7 5_AD23 A3:0 5_AD24 C#_BE0 A3:1 5_AD25 A3:2 5_AD26 AD11 A3:3 5_AD27 AD13 TMS809 AGP 3.0 Bus Support 3- 27...
  • Page 86 6_AD23 - - - - - - C1:0 6_AD24 C1:1 6_AD25 AD24 C1:2 6_AD26 AD26 C1:3 6_AD27 AD28 C1:4 6_AD28 AD30 C1:5 6_AD29 SBA7# C1:6 6_AD30 SBA5# C1:7 6_AD31 SB_STBS C2:0 7_AD16 SBA0# TMS809 AGP 3.0 Bus Support 3- 28...
  • Page 87 - - - - - - D0:2 4_AD2 - - - - - - D0:3 4_AD3 - - - - - - D0:4 4_AD4 - - - - - - D0:5 4_AD5 - - - - - - TMS809 AGP 3.0 Bus Support 3- 29...
  • Page 88 - - - - - - D2:7 5_AD7 - - - - - - D3:0 5_AD8 USB+ D3:1 5_AD9 D3:2 5_AD10 D3:3 5_AD11 DBI_HI D3:4 5_AD12 MB_DET# D3:5 5_AD13 D3:6 5_AD14 INTA# D3:7 5_AD15 GC_DET# TMS809 AGP 3.0 Bus Support 3- 30...
  • Page 89 6_AD11 E1:4 6_AD12 E1:5 6_AD13 E1:6 6_AD14 E1:7 6_AD15 E2:0 7_AD0 E2:1 7_AD1 E2:2 7_AD2 E2:3 7_AD3 E2:4 7_AD4 E2:5 7_AD5 E2:6 7_AD6 E2:7 7_AD7 E3:0 7_AD8 E3:1 7_AD9 E3:2 7_AD10 E3:3 7_AD11 TMS809 AGP 3.0 Bus Support 3- 31...
  • Page 90 4_C#_BE2 S_A0:3 4_C#_BE3 S_A0:4 5_C#_BE0 S_A0:5 5_C#_BE1 S_A0:6 5_C#_BE2 S_A0:7 5_C#_BE3 S_A1:0 6_C#_BE0 S_A1:1 6_C#_BE1 S_A1:2 6_C#_BE2 S_A1:3 6_C#_BE3 S_A1:4 7_C#_BE0 S_A1:5 7_C#_BE1 S_A1:6 7_C#_BE2 S_A1:7 7_C#_BE3 S_A2:0 1_AD16 S_A2:1 1_AD17 S_A2:2 1_AD18 TMS809 AGP 3.0 Bus Support 3- 32...
  • Page 91 Table 3- 40: Slave Control Module 32-channel assignments Logic analyzer AGP 3.0 support acquisition channel channel name S_C0:0 2_AD16 S_C0:1 2_AD17 S_C0:2 2_AD18 S_C0:3 2_AD19 S_C0:4 2_AD20 S_C0:5 2_AD21 S_C0:6 2_AD22 S_C0:7 2_AD23 S_C1:0 2_AD24 S_C1:1 2_AD25 TMS809 AGP 3.0 Bus Support 3- 33...
  • Page 92 2_AD31 S_C2:0 3_AD16 S_C2:1 3_AD17 S_C2:2 3_AD18 S_C2:3 3_AD19 S_C2:4 3_AD20 S_C2:5 3_AD21 S_C2:6 3_AD22 S_C2:7 3_AD23 S_C3:0 3_AD24 S_C3:1 3_AD25 S_C3:2 3_AD26 S_C3:3 3_AD27 S_C3:4 3_AD28 S_C3:5 3_AD29 S_C3:6 3_AD30 S_C3:7 3_AD31 TMS809 AGP 3.0 Bus Support 3- 34...
  • Page 93 2_C#_BE3 S_D1:4 3_C#_BE0 S_D1:5 3_C#_BE1 S_D1:6 3_C#_BE2 S_D1:7 3_C#_BE3 S_D2:0 1_AD0 S_D2:1 1_AD1 S_D2:2 1_AD2 S_D2:3 1_AD3 S_D2:4 1_AD4 S_D2:5 1_AD5 S_D2:6 1_AD6 S_D2:7 1_AD7 S_D3:0 1_AD8 S_D3:1 1_AD9 S_D3:2 1_AD10 S_D3:3 1_AD11 TMS809 AGP 3.0 Bus Support 3- 35...
  • Page 94 2_AD2 S_E0:3 2_AD3 S_E0:4 2_AD4 S_E0:5 2_AD5 S_E0:6 2_AD6 S_E0:7 2_AD7 S_E1:0 2_AD8 S_E1:1 2_AD9 S_E1:2 2_AD10 S_E1:3 2_AD11 S_E1:4 2_AD12 S_E1:5 2_AD13 S_E1:6 2_AD14 S_E1:7 2_AD15 S_E2:0 3_AD0 S_E2:1 3_AD1 S_E2:2 3_AD2 TMS809 AGP 3.0 Bus Support 3- 36...
  • Page 95 Table 3- 43: Slave2 Address Module 32-channel assignments Logic analyzer AGP 3.0 support acquisition channel channel name S2_A0:0 0/PCI_AD0 S2_A0:1 0/PCI_AD1 S2_A0:2 0/PCI_AD2 S2_A0:3 0/PCI_AD3 S2_A0:4 0/PCI_AD4 S2_A0:5 0/PCI_AD5 S2_A0:6 0/PCI_AD6 S2_A0:7 0/PCI_AD7 TMS809 AGP 3.0 Bus Support 3- 37...
  • Page 96 0/PCI_AD15 S2_A2:0 0/PCI_AD16 S2_A2:1 0/PCI_AD17 S2_A2:2 0/PCI_AD18 S2_A2:3 0/PCI_AD19 S2_A2:4 0/PCI_AD20 S2_A2:5 0/PCI_AD21 S2_A2:6 0/PCI_AD22 S2_A2:7 0/PCI_AD23 S2_A3:0 0/PCI_AD24 S2_A3:1 0/PCI_AD25 S2_A3:2 0/PCI_AD26 S2_A3:3 0/PCI_AD27 S2_A3:4 0/PCI_AD28 S2_A3:5 0/PCI_AD29 S2_A3:6 0/PCI_AD30 S2_A3:7 0/PCI_AD31 TMS809 AGP 3.0 Bus Support 3- 38...
  • Page 97 5_SBA3# S2_C1:4 5_SBA4# S2_C1:5 5_SBA5# S2_C1:6 5_SBA6# S2_C1:7 5_SBA7# S2_C2:0 6_SBA0# S2_C2:1 6_SBA1# S2_C2:2 6_SBA2# S2_C2:3 6_SBA3# S2_C2:4 6_SBA4# S2_C2:5 6_SBA5# S2_C2:6 6_SBA6# S2_C2:7 6_SBA7# S2_C3:0 7_SBA0# S2_C3:1 7_SBA1# S2_C3:2 7_SBA2# S2_C3:3 7_SBA3# TMS809 AGP 3.0 Bus Support 3- 39...
  • Page 98 S2_D0:0 INTA# S2_D0:1 USB_NEG S2_D0:2 GC_DET S2_D0:3 TYPEDET# S2_D0:5 DEVSEL S2_D0:6 PERR S2_D0:7 SERR S2_D1:0 S2_D1:1 PME# S2_D1:2 STOP S2_D2:0 RESET# S2_D2:1 S2_D2:2 S2_D2:3 MB_DET# S2_D2:4 S2_D2:5 S2_D2:6 S2_D2:7 S2_D3:0 TMS809 AGP 3.0 Bus Support 3- 40...
  • Page 99 0/PCI_SBA3# S2_E0:4 0/PCI_SBA4# S2_E0:5 0/PCI_SBA5# S2_E0:6 0/PCI_SBA6# S2_E0:7 0/PCI_SBA7# S2_E1:0 1_SBA0# S2_E1:1 1_SBA1# S2_E1:2 1_SBA2# S2_E1:3 1_SBA3# S2_E1:4 1_SBA4# S2_E1:5 1_SBA5# S2_E1:6 1_SBA6# S2_E1:7 1_SBA7# S2_E2:0 2_SBA0# S2_E2:1 2_SBA1# S2_E2:2 2_SBA2# S2_E2:3 2_SBA3# TMS809 AGP 3.0 Bus Support 3- 41...
  • Page 100 Logic analyzer AGP 3.0 support acquisition channel channel name S2_E2:4 2_SBA4# S2_E2:5 2_SBA5# S2_E2:6 2_SBA6# S2_E2:7 2_SBA7# S2_E3:0 3_SBA0# S2_E3:1 3_SBA1# S2_E3:2 3_SBA2# S2_E3:3 3_SBA3# S2_E3:4 3_SBA4# S2_E3:5 3_SBA5# S2_E3:6 3_SBA6# S2_E3:7 3_SBA7# TMS809 AGP 3.0 Bus Support 3- 42...
  • Page 101 2_SBA[7:0]# @ AD_STBF1 4_SBA[7:0]# @ AD_STBS1 6_SBA[7:0]# @ AD_STBF0 PHASE_D @ AD_STBS0 FRAME SBA_STBF IRDY SBA_STBS TRDY 8X/PCI#_AD_D NOTE. Many of the signals in this table are used to derive PHASE_D and 8X/PCI#_AD_D. TMS809 AGP 3.0 Bus Support 3- 43...
  • Page 102 Channel Assignment Tables TMS809 AGP 3.0 Bus Support 3- 44...
  • Page 103: Specifications

    Specifications...
  • Page 105 AGP 3.0 bus support package. These specifications are for a probe adapter connected between a compatible Tektronix logic analyzer and a target system. Table 4- -1 lists the electrical requirements the target system must produce for the support to acquire correct data.
  • Page 106: Figure 4- 1: Strobe Separation

    Table 4- 2: Timing Support Channel- to- Channel Skew AGP3_T support channel name Skew + 0.37 Ns RESET# +/- - 1.0 SB_STBF + 0.1 TMS809 AGP 3.0 Bus Support 4- 2...
  • Page 107 2 in (5.08 cm) Back 3 in (7.62 cm) Designed to meet Tektronix standard 062-2847-00 class 5. Not to exceed AGP 3.0 bus thermal considerations. Forced air cooling is required. CAUTION. To prevent damage to the circuitry in the preprocessor unit, you must observe the required clearances in Table 4- -4.
  • Page 108: Figure 4- 2: Interposer Source Sync Load Model

    0.05 Ω 0.05 Ω AGP 3.0 a = Attenuation in -dB meter at connector 1 GHz Signal 1 Signal 2 Micro Pogo pin exploded view Figure 4- 3: Backside source sync load model TMS809 AGP 3.0 Bus Support 4- 4...
  • Page 109 Specifications Table 4- -5 lists the certifications and compliances for the TMS809 AGP 3.0 bus support package. Table 4- 5: Certifications and compliances Category Standards or description EC Declaration of Conformity — Compliance was demonstrated to the following specifications as listed in the Official Journal of the...
  • Page 110 Class 1 (as defined in IEC 61010-1, Annex H) - - grounded product Overvoltage Category Overvoltage Category II (as defined in IEC 61010-1, Annex J) Pollution Degree Pollution Degree 2 (as defined in IEC 61010-1). Note: Rated for indoor use only. TMS809 AGP 3.0 Bus Support 4- 6...
  • Page 111: Figure 4- 4: Dimensions Of The Agp 3.0 Interposer Probe Head

    Figure 4- -4 shows the dimensions of the AGP 3.0 Interposer probe head. Mother board 28.82 mm (1.135 in) 215.90 mm (8.500 in) 169.24 mm AGP 3.0 (6.663 in) graphics card Mother board Figure 4- 4: Dimensions of the AGP 3.0 Interposer probe head TMS809 AGP 3.0 Bus Support 4- 7...
  • Page 112: Figure 4- 5: Dimensions Of The Agp 3.0 Backside Probe Head

    Mother board 41.91 mm (1.650 in) 148.59 mm (5.850 in) 76.20 mm (3.000 in) 215.90 mm 38.76 mm (8.500 in) (1.526 in) Figure 4- 5: Dimensions of the AGP 3.0 Backside probe head TMS809 AGP 3.0 Bus Support 4- 8...
  • Page 113: Figure 4- 6: Dimensions Of The Preprocessor Unit

    Table 4- -4 on page 4- -3. 474.32 mm (18.674 in) 425.45 mm (16.750 in) 420.37 mm (16.550 in) 139.70 mm 160.27 mm (5.500 in) (6.310 in) Figure 4- 6: Dimensions of the preprocessor unit TMS809 AGP 3.0 Bus Support 4- 9...
  • Page 114 Specifications TMS809 AGP 3.0 Bus Support 4- 10...
  • Page 115 WARNING The following servicing instructions are for use only by qualified personnel. To avoid injury, do not perform any servicing other than that stated in the operating instructions unless you are qualified to do so. Refer to all safety summaries before performing any service.
  • Page 117: Maintenance

    Maintenance...
  • Page 119 Tektronix authorized personnel only. External parts may be replaced by qualified service personnel. Fuses The fuses for the TMS809 AGP 3.0 probe adapter are located in the preprocessor unit. See the Replaceable Parts List for the part numbers. H In the power supply, there is one fuse:...
  • Page 120 Maintenance TMS809 AGP 3.0 Bus Support 5- 2...
  • Page 121 Fan Removal and Installation Procedure This section contains fan removal and installation procedures for the TMS809 probe adapter. The information in this section is designed for use by qualified service personnel. Read the Safety Summaries at the front of this manual before attempting any procedures in this section.
  • Page 122: Figure 5- -1: Power Switch And Ac Power Cord Locations

    (see Figure 5- -1). 2. Disconnect the P6434 probes. To disconnect the P6434 probes, refer to the P6434 Mass Termination Probe manual, Tektronix part number 070-9793-XX, for more information on mechanical specifications. 3. Unplug the AC power cord from the preprocessor unit.
  • Page 123: Figure 5- -2: Remove The Attaching Screws

    5. Remove the screws (see Figure 5- -2) from the bottom cover of the preproces- sor unit. Set the bottom cover aside. Preprocessor unit bottom Screws (6) Figure 5- - 2: Remove the attaching screws TMS809 AGP 3.0 Bus Support 5- - 5...
  • Page 124: Figure 5- -3: Remove The Bottom Cover

    7. Disconnect the fan connector from the logic-board connector (see Fig- ure 5- -3) by pressing the release tab on the fan connector. 8. Cut the two cable ties that bundle the fan wires together. TMS809 AGP 3.0 Bus Support 5- - 6...
  • Page 125: Figure 5- -4: Removing The Fan Pin Connector

    10. Remove the rivets, fan guard, and fan from the preprocessor unit. When removing the rivets, pull the rivet pin halfway out and then remove the whole rivet assembly. 11. Remove the fan from the preprocessor unit. TMS809 AGP 3.0 Bus Support 5- - 7...
  • Page 126: Figure 5- -5: Back Of The Preprocessor Unit

    5. Slide and snap the fan pin into the fan connector housing. Gently pull on the fan pin to insure the fan pin has seated in the fan connector. 6. Connect the fan connector to the Logic-board connector (see Figure 5- -3 on page 5- -6). TMS809 AGP 3.0 Bus Support 5- - 8...
  • Page 127: Figure 5- -6: Location Of Fan Connector

    13. Attach the P6434 probes (see page 1- -20). If the replaced fan is not working: H Check that the fan pin is seated properly in the fan connector housing. H Check that the fan connector has snapped into place. TMS809 AGP 3.0 Bus Support 5- - 9...
  • Page 128 Fan Removal and Installation Procedure TMS809 AGP 3.0 Bus Support 5- - 10...
  • Page 129: Replaceable Parts List

    Replaceable Parts List...
  • Page 131: Parts Ordering Information

    For more information about the module exchange program, call 1-800-833-9200. Outside North America, contact a Tektronix sales office or distributor; see the Tektronix web site for a list of offices: www.tektronix.com. Module Repair and Return. You may ship your module to us for repair, after which we will return it to you.
  • Page 132 Using the Replaceable Parts List This section contains a list of the mechanical and/or electrical components that are replaceable for the TMS809 AGP 3.0 probe adapter. Use this list to identify and order replacement parts. The following table describes each column in the parts list.
  • Page 133 ATTN: ALICIA SANFORD ROCKFORD, IL 611045181 516 18TH AVE TK1547 MOORE ELECTRONICS INC 19500 SW 90TH CT TUALATIN, OR 97062 PO BOX 1030 72113 ESCO CORPORATION 2141 N W 25TH PORTLAND, OR 97210 TMS809 AGP 3.0 Bus Support 6- - 3...
  • Page 134: Figure 6- -1: Interposer Probe Head Exploded View

    Mfr. part number number 6--1--1 672--5506--50 CIRCUIT BD ASSY:AGP8X INTERPOSER PROBE 80009 672--5506--00 W/CABLES,TMS809 214--3796--00 HEAT SINK,SEMIC:ALUMINUM,TO--220,VERTICAL ECB 30161 576802B03900 MOUNT,TINNED TAB,576802B03900 Figure 6- - 1: Interposer probe head exploded view TMS809 AGP 3.0 Bus Support 6- - 4...
  • Page 135 WASHER,SHLDR:0.14 ID X 0.375 OD X 0.1 THK,DERLIN 0KB01 210--0975--00 220--0260--00 NUT:EXTENSION NUT,DRILL/TAP FOR 2--56 THREAD,301 TK0588 220--0260--00 SSTL 119--6803--00 ASSEMBLY,POGO PIN;TMS809 80009 119--6803--00 211--0112--00 SCREW,MACHINE:2--56 X 0.375,FLH,100 DEG,STL CD 93907 ORDER BY PL,POZ DESCRIPTION 391--0245--00 BLOCK,MOUNTING:FR4,TMS809 5Y400 391--0245--00 TMS809 AGP 3.0 Bus Support 6- - 5...
  • Page 136 Replaceable Parts List Figure 6- - 2: Backside probe head exploded view TMS809 AGP 3.0 Bus Support 6- - 6...
  • Page 137 Mfr. index number effective discont’d Name & description code Mfr. part number number 6--3--1 671--5505--00 CIRCUIT BD ASSY:AGP8X LOGIC, WIRED,TMS809 80009 671--5505--50 174--2699--00 CA,ASSY SP:DISCRETE,SLDR/CRIMP,26 AWG,10.0 L,1 X TK1547 174--2699--00 2,0.1 CTR RCPT X GRN LED 210--0390--00 RIVET,SNAP:0.501 LONG,WHEN 06915...
  • Page 138 FUSE),UK PLUG,(13A FUSE),UNITED KINGDOM,SAFTEY CONTROLLED 161--0167--00 CA ASSY,PWR:3,0.75MM SQ,250V/10A,2.5 S3109 ORDER BY METER,RTANG,IEC320,RCPT,SWISS,NO CORD DESCRIPTION GRIP,SAFTEY CONTROLLED Check the P6434 Probe manual or P6860 Probe manual (Tektronix.com.) for detailed replaceable part number information. TMS809 AGP 3.0 Bus Support 6- - 8...
  • Page 139 Replaceable Parts List Figure 6- - 3: Preprocessor unit exploded view TMS809 AGP 3.0 Bus Support 6- - 9...
  • Page 140 Replaceable Parts List TMS809 AGP 3.0 Bus Support 6- - 10...
  • Page 141 Index...
  • Page 143 P6434, 1- - 20 7_AD[31:0], 3- - 5 P6860, 1- - 2, 1- - 20 0/PCI_AD[31], 3- - 14 verifying probe operations, 1- - 23 0/PCI_C#_BE[3:0], 3- - 17 Contacting Tektronix, xii 1_C#_BE[3:0], 3- - 17 TMS809 AGP 3.0 Bus Support Index- 1...
  • Page 144 Master and slave configuration, 1- - 20 Slave2 E, channel assignments, 3- - 41 Specifications channel assignments, 3- - 5, 3- - 25 electrical, 4- - 1 mechanical (dimensions), 4- - 7, 4- - 9 TMS809 AGP 3.0 Bus Support Index- 2...
  • Page 145 Status channel group, 3- - 2 Viewing disassembled data, 2- - 5 Symbol tables overview, 2- - 2 Waveform display, 2- - 5 Table conventions, 3- - 5 Web site address, Tektronix, xii TMS809 AGP 3.0 Bus Support Index- 3...
  • Page 146 Index TMS809 AGP 3.0 Bus Support Index- 4...