Tektronix THDP0100 Instruction Manual

High voltage differential probes
Hide thumbs Also See for THDP0100:

Advertisement

Quick Links

x
THDP0100/0200 & TMDP0200
High Voltage Differential Probes
ZZZ
Instruction Manual
*P077054001*
077-0540-01

Advertisement

Table of Contents
loading

Summary of Contents for Tektronix THDP0100

  • Page 1 THDP0100/0200 & TMDP0200 High Voltage Differential Probes Instruction Manual *P077054001* 077-0540-01...
  • Page 3: Instruction Manual

    THDP0100/0200 & TMDP0200 High Voltage Differential Probes Instruction Manual Revision C www.tek.com 077-0540-01...
  • Page 4 Copyright © Tektronix. All rights reserved. Licensed software products are owned by Tektronix or its subsidiaries or suppliers, and are protected by national copyright laws and international treaty provisions. Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication supersedes that in all previously published material.
  • Page 5 Warranty Tektronix warrants that this product will be free from defects in materials and workmanship for a period of one (1) year from the date of shipment. If any such product proves defective during this warranty period, Tektronix, at its option, either will repair the defective product without charge for parts and labor, or will provide a replacement in exchange for the defective product.
  • Page 7: Table Of Contents

    THDP0100 Probe Standard Accessories ............
  • Page 8 Table of Contents THDP0100/0200 & TMDP0200 High Voltage Differential Probes Instruction Manual...
  • Page 9: General Safety Summary

    Avoid exposed circuitry. Do not touch exposed connections and components when power is present. Do not operate in wet/damp conditions. Do not operate in an explosive atmosphere. Keep product surfaces clean and dry. THDP0100/0200 & TMDP0200 High Voltage Differential Probes Instruction Manual...
  • Page 10 DANGER indicates an injury hazard immediately accessible as you read the marking. WARNING indicates an injury hazard not immediately accessible as you read the marking. CAUTION indicates a hazard to property including the product. The following symbol(s) may appear on the product: THDP0100/0200 & TMDP0200 High Voltage Differential Probes Instruction Manual...
  • Page 11: Compliance Information

    Complies with the EMC provision of the Radiocommunications Act per the following standard, in accordance with ACMA: CISPR 11:2003. Radiated and Conducted Emissions, Group 1, Class A, in accordance with EN 61326-1:2006 and EN 61326-2-1:2006. THDP0100/0200 & TMDP0200 High Voltage Differential Probes Instruction Manual...
  • Page 12: Safety Compliance

    Pollution Degree 4. Pollution that generates persistent conductivity through conductive dust, rain, or snow. Typical outdoor locations. Pollution Degree Pollution Degree 2 (as defined in IEC 61010-1). Note: Rated for indoor use only. THDP0100/0200 & TMDP0200 High Voltage Differential Probes Instruction Manual...
  • Page 13 Measurement Category III. For measurements performed in the building installation. Measurement Category II. For measurements performed on circuits directly connected to the low-voltage installation. Measurement Category I. For measurements performed on circuits not directly connected to MAINS. THDP0100/0200 & TMDP0200 High Voltage Differential Probes Instruction Manual...
  • Page 14: Environmental Considerations

    This symbol indicates that this product complies with the applicable European Union requirements according to Directives 2002/96/EC and 2006/66/EC on waste electrical and electronic equipment (WEEE) and batteries. For information about recycling options, check the Support/Service section of the Tektronix Web site (www.tek.com).
  • Page 15: Preface

    Preface Preface This document provides operating information and specifications for the Tektronix THDP0100/0200 & TMDP0200 high voltage differential probes. The probes share similar functions, properties, and operating procedures, and are discussed first, followed by the specifications, which differ by probe model. Service procedures include performance verification and adjustments.
  • Page 16 Preface Figure ii: THDP0200 probe with accessories THDP0100/0200 & TMDP0200 High Voltage Differential Probes Instruction Manual...
  • Page 17 Preface Figure iii: TMDP0200 probe with accessories THDP0100/0200 & TMDP0200 High Voltage Differential Probes Instruction Manual...
  • Page 18: Probe Operating Information

    If the wear indicator is visible, do not use the probe. Contact Tektronix Service for repair or replacement. 4. Use the probe accessories to connect the probe inputs to the circuit points to be measured. (See page 6, Accessories.) WARNING.
  • Page 19: Connecting To The Circuit

    Do not connect or disconnect accessories or extended test leads to a voltage source unless they are first connected to the probe. THDP0100/0200 & TMDP0200 High Voltage Differential Probes Instruction Manual...
  • Page 20: Probe Controls And Indicators

    (See page 53, Error Conditions .) Menu Button Press the MENU button to display on-screen probe controls on the oscilloscope. Many probe functions are available, such as AutoZero and range selection. THDP0100/0200 & TMDP0200 High Voltage Differential Probes Instruction Manual...
  • Page 21 first. Make a single-ended measurement by tying one input lead to ground (the "–" input) and then connecting the other lead (the “+" input) to the points of interest, one at a time. THDP0100/0200 & TMDP0200 High Voltage Differential Probes Instruction Manual...
  • Page 22 first powered on. Press the AUDIBLE OVERRANGE button to light the OFF LED and disable the feature. To enable the alarm, press the button again to light the ON LED. THDP0100/0200 & TMDP0200 High Voltage Differential Probes Instruction Manual...
  • Page 23: Accessories

    WARNING. To avoid risk of electric shock or fire, do not use the THDP0100 test probe or hook tip accessories on CAT III or CAT IV circuits. Refer to the ratings tables in the Accessories section of the manual. (See Table 1 on page 9.) To avoid risk of electric shock or fire, when using the THDP0100 test probe or hook tip accessories with the THDP0200 and...
  • Page 24 WARNING. To prevent arc flash, do not use the test probe or hook tips on CAT III circuits. To probe CAT III circuits, use the AC280-FL, AC283-FL, or AC285-FL accessories. THDP0100/0200 & TMDP0200 High Voltage Differential Probes Instruction Manual...
  • Page 25 Maximum ratings: 2300 V CAT I* 1000 V CAT II * See Specifications for the Over-Voltage Transient (OVT) rating for the probe that you are using. (See Table 6 on page 27.) THDP0100/0200 & TMDP0200 High Voltage Differential Probes Instruction Manual...
  • Page 26 600 V CAT II 300 V CAT II The THDP0200 & TMDP0200 standard accessories can be used with the THDP0100 probe at the reduced voltage levels listed in this table. Table 2: Voltage derating for THDP0200 & TMDP0200 probe standard accessories...
  • Page 27: Thdp0200 & Tmdp0200 Probe Standard Accessories

    To avoid electric shock when using the probe or accessories, keep your fingers behind the finger guard of the probe body and away from the shaded area shown in the accessory illustrations below. THDP0100/0200 & TMDP0200 High Voltage Differential Probes Instruction Manual...
  • Page 28 Maximum ratings: 1000 V CAT II 1000 V CAT III 10 A One pair of handheld probes are included with the probes. Reorder Tektronix part number: TP175-FL (one pair) THDP0100/0200 & TMDP0200 High Voltage Differential Probes Instruction Manual...
  • Page 29 Maximum ratings: 150 V CAT II 1 mA Reorder Tektronix part number: 020-3107-xx (includes 2 Tip Adapters, 2 Cone-Tip Pogo Pins, & 2 Serrated-Tip Pogo Pins) THDP0100/0200 & TMDP0200 High Voltage Differential Probes Instruction Manual...
  • Page 30 Maximum ratings: 1000 V CAT III One pair of hook clips are included with the probes. Reorder Tektronix part number: AC280-FL (one pair) THDP0100/0200 & TMDP0200 High Voltage Differential Probes Instruction Manual...
  • Page 31 Maximum ratings: 1000 V CAT III 10 A One pair of clips is included with the probes. Reorder Tektronix part number: 344-0670-xx (one pair) THDP0100/0200 & TMDP0200 High Voltage Differential Probes Instruction Manual...
  • Page 32 Tektronix recommends that you use insulated probe tip accessories designed to prevent short-circuiting adjacent IC pins or circuitry. One TPH1000 probe holder is included with the probes. Reorder Tektronix part number: TPH1000 THDP0100/0200 & TMDP0200 High Voltage Differential Probes Instruction Manual...
  • Page 33 6. Position the probe tips on your test points so that you can set the holder on a stable surface. One THV-Browser is included with the probes. Reorder Tektronix part number: THV-Browser THDP0100/0200 & TMDP0200 High Voltage Differential Probes Instruction Manual...
  • Page 34: Thdp & Tmdp Series Probes Optional Accessories

    If the original label becomes damaged or lost, order a replacement label. Order Tektronix part number: 335-2913-xx THDP0100/0200 & TMDP0200 High Voltage Differential Probes Instruction Manual...
  • Page 35: Options

    Option D3. Calibration Data Report, 3 years (with Option C3) Option D5. Calibration Data Report, 5 years (with Option C5) Option R3. Repair Service 3 years Option R5. Repair Service 5 years THDP0100/0200 & TMDP0200 High Voltage Differential Probes Instruction Manual...
  • Page 36: Functional Check

    ~20% over Hot (same Common High or low No signal connection) Mode If a DC offset voltage is present, zero the DC offset using the AutoZero function. (See page 20, AutoZero.) THDP0100/0200 & TMDP0200 High Voltage Differential Probes Instruction Manual...
  • Page 37 2. Connect the probe inputs together with the hook tips. 3. Press and hold the probe BANDWIDTH LIMIT and RANGE buttons until the OVERRANGE LED on the probe begins flashing, and then quickly release the buttons (about 2 seconds). THDP0100/0200 & TMDP0200 High Voltage Differential Probes Instruction Manual...
  • Page 38 DC offset has been stored. 5. Repeat steps 2 through 4 for the other range setting on the probe. 6. Perform the DC Offset Zero procedure as described in the previous section. THDP0100/0200 & TMDP0200 High Voltage Differential Probes Instruction Manual...
  • Page 39: Operating Basics

    (the common mode voltage specification). The maximum common mode voltage limits vary between probes, from 550 V CAT I for the TMDP0200, to 2300 V CAT I for the THDP0100 probe.
  • Page 40 ). Looking at the maximum measurable differential voltage specifications for the THDP/TMDP series probes, the THDP0100 probe is capable of measuring this signal. (See Table 6 on page 27.) For reference, the rms values of the Common-Mode Voltage and Voltage-to-Earth ratings and Maximum Input Signals for each probe model are shown in the figure above.
  • Page 41 Although this is a lower potential between the inputs than in example 1, it exceeds the differential voltage ratings of the THDP0200 and TMDP0200 probes, so you must use the THDP0100 probe. Figure 4: Measuring two equal-amplitude waveforms that are 120 degrees out of phase Example 3.
  • Page 42 Specifications section. As the graph shows, the probes have virtually no loading effect on sources with relatively low impedance and low frequency. THDP0100/0200 & TMDP0200 High Voltage Differential Probes Instruction Manual...
  • Page 43: Specifications

    Specifications Specifications The specifications shown apply to the THDP/TMDP series probes installed on Tektronix MSO/DSO4000 oscilloscopes. When a probe is used with another oscilloscope, the oscilloscope must have an input impedance of 1 MΩ and a bandwidth equal to or greater than the probe. The probe must have a warm-up period of at least 20 minutes and be in an environment that does not exceed the limits described.
  • Page 44: Typical Characteristics

    The Common Mode ratings are the same as the input voltage-to-earth ratings (the maximum amount that each input lead (+/-) can be from ground). Applies to CAT I ratings only (both ranges). The OVT peak is typically measured on top of the Peak Working Voltage. THDP0100/0200 & TMDP0200 High Voltage Differential Probes Instruction Manual...
  • Page 45: Mechanical Characteristics

    76 mm x 31 mm x 41 mm (3.0 in x 1.2 in x 1.6 in) Input cable length 25.4 cm (10 in) Output cable length 1.5 m (59 in) Weight (probe only) 340 gm (12.0 oz) 309 gm (10.9 oz) 309 gm (10.9 oz) THDP0100/0200 & TMDP0200 High Voltage Differential Probes Instruction Manual...
  • Page 46: Nominal Characteristics

    + input lead while the – input lead is grounded (by taking a single-ended measurement). Performance Graphs Figure 5: THDP0100/0200 and TMDP0200 impedance plots THDP0100/0200 & TMDP0200 High Voltage Differential Probes Instruction Manual...
  • Page 47 Specifications Figure 6: THDP0100 voltage derating curve Figure 7: THDP0200 voltage derating curve THDP0100/0200 & TMDP0200 High Voltage Differential Probes Instruction Manual...
  • Page 48 Specifications Figure 8: TMDP0200 voltage derating curve Figure 9: THDP0100 rise time (typical) THDP0100/0200 & TMDP0200 High Voltage Differential Probes Instruction Manual...
  • Page 49 Specifications Figure 10: THDP0200 rise time (typical) Figure 11: TMDP0200 rise time (typical) THDP0100/0200 & TMDP0200 High Voltage Differential Probes Instruction Manual...
  • Page 50: Performance Verification

    Fluke PM9081 Termination BNC feedthrough, 50Ω Tektronix part number 011-0049-xx Attenuator BNC, 50Ω, 2X Tektronix part number 011-0069-xx Probe hook tips (2) Included with probe accessory kit Tektronix part number AC280–FL THDP0100/0200 & TMDP0200 High Voltage Differential Probes Instruction Manual...
  • Page 51 fixture. The signal can then be measured with another instrument, such as a precision DMM, to check and adjust the gain accuracy of the probe. Order Tektronix part number 067-1701-xx. Figure 12: TekVPI calibration fixture THDP0100/0200 & TMDP0200 High Voltage Differential Probes Instruction Manual...
  • Page 52: Test Procedures

    4. Turn on the remaining test equipment and let the probe and equipment warm up for 20 minutes. 5. Make a copy of the test record to tabulate the test results. (See Table 13 on page 38.) THDP0100/0200 & TMDP0200 High Voltage Differential Probes Instruction Manual...
  • Page 53 1500 V 75 V 100 Hz 150 mV ±3 mV TMDP0200 75 V 20 V 100 Hz 800 mV ±16 mV 750 V 60 V 100 Hz 240 mV ±4.8 mV THDP0100/0200 & TMDP0200 High Voltage Differential Probes Instruction Manual...
  • Page 54: Rise Time

    50 V 1 kHz ≤2.4 ns 1500 V 50 V 1 kHz ≤2.0 ns TMDP0200 75 V 50 V 1 kHz ≤2.4 ns 750 V 50 V 1 kHz ≤2.0 ns THDP0100/0200 & TMDP0200 High Voltage Differential Probes Instruction Manual...
  • Page 55 600 V 3.6 ns — 6000 V 3.6 ns — THDP0200 150 V 2.4 ns — 1500 V 2.0 ns — TMDP0200 75 V 2.4 ns — 750 V 2.0 ns THDP0100/0200 & TMDP0200 High Voltage Differential Probes Instruction Manual...
  • Page 56: Adjustments

    Only probes with serial numbers C020000 and above have internal adjustments. (See Table 14.) Probes with serial numbers C019999 and below that require adjustments (other than offset zero) must be returned to Tektronix for service. Table 14: THDP & TMDP Series probe adjustments Specification...
  • Page 57 Adjustments Figure 13: Probe serial number and adjustment locations THDP0100/0200 & TMDP0200 High Voltage Differential Probes Instruction Manual...
  • Page 58: Equipment Required

    The original label is backed with a reusable adhesive. If the label does not sufficiently adhere to the probe, order a replacement. Label removal is not required to access offset zero adjustments THDP0100/0200 & TMDP0200 High Voltage Differential Probes Instruction Manual...
  • Page 59: Adjustment Procedures

    2. Connect the probe to any channel of the oscilloscope. 3. Verify that the LEDs light on the probe. 4. Turn on the remaining test equipment and let the probe and equipment warm up for 20 minutes. THDP0100/0200 & TMDP0200 High Voltage Differential Probes Instruction Manual...
  • Page 60 6. Press the AUDIBLE OVERRANGE button on the probe to store the adjusted offset value. The OVERRANGE LED stops flashing to indicate that the offset value is stored and that the adjustment is disabled. 7. Select the remaining attenuation range and repeat steps 3 through 6. THDP0100/0200 & TMDP0200 High Voltage Differential Probes Instruction Manual...
  • Page 61 NOTE. Only probes with serial numbers C020000 and above have internal adjustments. (See Figure 14.) Probes with serial numbers C019999 and below that require adjustments (other than offset zero) must be returned to Tektronix for service. WARNING. The remaining adjustments for the probe require you to remove a reusable label from the back of the probe. You must replace the label after you complete the probe adjustments.
  • Page 62 1500 V 75 V 100 Hz 150 mV ±3 mV TMDP0200 75 V 20 V 100 Hz 800 mV ±16 mV 750 V 60 V 100 Hz 240 mV ±4.8 mV THDP0100/0200 & TMDP0200 High Voltage Differential Probes Instruction Manual...
  • Page 63 12. Set the probe attenuation to the next range and set the generator output voltage to the value shown in the table. 13. Enable the generator output and adjust the high-range DC gain pot in the probe to ≤2% of the expected output. 14. Disable the generator output. THDP0100/0200 & TMDP0200 High Voltage Differential Probes Instruction Manual...
  • Page 64 6. Enable the generator output. Set the oscilloscope vertical to display the signal. For a stable display, connect the generator Sense output to another channel and trigger off of that channel. THDP0100/0200 & TMDP0200 High Voltage Differential Probes Instruction Manual...
  • Page 65 Use averaging or hi-res filters to make viewing the 40 Hz signal easier. WARNING. Use only an insulated tool to make the adjustment. Failure to do so presents a potential shock hazard. 8. Disable the generator output. THDP0100/0200 & TMDP0200 High Voltage Differential Probes Instruction Manual...
  • Page 66 50 V 10 kHz THDP0200 150 V 50 V 10 kHz TMDP0200 75 V 50 V 10 kHz 7. Enable the generator output. Set the oscilloscope vertical to display the signal. THDP0100/0200 & TMDP0200 High Voltage Differential Probes Instruction Manual...
  • Page 67 12. Enable the generator output and make the adjustments in the following order: long-term –LF, long-term –LF*, short-term –LF. (The long-term –LF* adjustment is not used in the TMDP0200 probe.) Repeat this sequence as necessary to optimize the square-wave response. THDP0100/0200 & TMDP0200 High Voltage Differential Probes Instruction Manual...
  • Page 68 4. Set the oscilloscope horizontal to 10 μs/div. 5. Set the probe bandwidth to full and the attenuation to the lower range of the probe. 6. Enable the generator output. Adjust the oscilloscope vertical to display the signal. THDP0100/0200 & TMDP0200 High Voltage Differential Probes Instruction Manual...
  • Page 69 +LF, long-term +LF, long-term +LF*. (The long-term +LF* adjustment is not used in the TMDP0200 probe.) WARNING. Use only an insulated tool to make the adjustment. Failure to do so presents a potential shock hazard. This completes the adjustment procedures. THDP0100/0200 & TMDP0200 High Voltage Differential Probes Instruction Manual...
  • Page 70: Troubleshooting

    Disconnect the probe from the oscilloscope, power-cycle the oscilloscope, and then reconnect the probe. Connect the probe to a different oscilloscope. If the symptoms remain (they follow the probe), then the probe is defective and must be returned to Tektronix for repair. Signal Display If the probe is connected to an active signal source and you do not see the signal displayed on the oscilloscope: Check that the probe accessories that you are using are fully mated.
  • Page 71: Cleaning

    Service There are no user-serviceable parts in the probes. If your probe requires service, contact your Tektronix service representative or repair center for instructions on returning your probe for repair. THDP0100/0200 & TMDP0200 High Voltage Differential Probes Instruction Manual...
  • Page 72 Troubleshooting THDP0100/0200 & TMDP0200 High Voltage Differential Probes Instruction Manual...
  • Page 73 Overrange indicator, 4 LEDs, 53 Probe release button, 3 signal display, 53 Range, 5 Status indicator, 3 Probe controls and indicators, 3 Probe inputs, 4 Firmware, 53 Probe loading, 25 Functional check, 19 THDP0100/0200 & TMDP0200 High Voltage Differential Probes Instruction Manual...

This manual is also suitable for:

Thdp0200Tmdp0200

Table of Contents