Download Print this page

Advertisement

Available languages

Available languages

Quick Links

Installation
1
4
Vedligeholdelse, Maintenance, Wartung, Entretien
6
Kun DN 80 - 200
Only DN 80 - 200
Nur DN 80 - 200
Uniquement DN 80 - 200
© Danfoss A/S (AC-DSL / MWA), 06-2006
Instructions
SVA-ST/SVA-SS 5 - 200
7
10
DKRCI.PI.KD0.A2.52 / 520H0745
2
5a
5b
8
DN 5-20
DN 25-40
DN 50-65-80-00
DN 25-50-200
3
DN 5-20
DN 25-32-40-50
DN 65
DN 80
DN 00
DN 25-50
DN 200
Nm
LB-feet
50
37
70
52
60
45
80
60
Nm
LB-feet
22
6
44
32
75
53
44
32
75
53
83
35
370
272
9
11


Advertisement

loading
Need help?

Need help?

Do you have a question about the SVA-ST 15 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Danfoss SVA-ST 15

  • Page 1 Vedligeholdelse, Maintenance, Wartung, Entretien Kun DN 80 - 200 Only DN 80 - 200 Nur DN 80 - 200 Uniquement DN 80 - 200 LB-feet DN 5-20 DN 25-40 DN 50-65-80-00 DN 25-50-200 © Danfoss A/S (AC-DSL / MWA), 06-2006 DKRCI.PI.KD0.A2.52 / 520H0745...
  • Page 2: Installation

    Når funktionen. svejsear-bejdet er færdigt, bør ventilen Kontakt venligst Danfoss i tilfælde af tvivl. Trykudligning (fig. 7) rengøres indvendigt for at fjerne svejse- slagger, før den samles igen. I nogle tilfælde dannes der tryk bag pak- Danfoss påtager sig intet ansvar for...
  • Page 3 (SVA-LT, SVA-SS). SVA-ST/LT 200 ........6 mm A/F Assembly Installation (An Allen key is included in the Danfoss Remove welding debris and any dirt from The valve must be installed with the Industrial Refrigeration gasket set). pipes and valve body before assembly.
  • Page 4 Der Druck lässt sich dann durch langsames Herausdrehen der Stopf- vor. Schweißrückstände und Schmutz in den +buchse ausgleichen. Gewinden des Gehäuses und des Ventil- deckels sind zu vermeiden. DKRCI.PI.KD0.A2.52 / 520H0745 © Danfoss A/S (AC-DSL / MWA), 06-2006...
  • Page 5 Il est possible de ne pas enlever le chapeau modifications à ses produits et à leurs presse-étoupe. sous réserve que : spécifications. © Danfoss A/S (AC-DSL / MWA), 06-2006 DKRCI.PI.KD0.A2.52 / 520H0745...
  • Page 6 DKRCI.PI.KD0.A2.52 / 520H0745 © Danfoss A/S (AC-DSL / MWA), 06-2006...
  • Page 7: Declaration Of Conformity

    References of other Technical Standards and Specifications used prEN 2284 DIN 358 AD-Merkblätter 2000 Authorised Person for the Manufacturer's Representative within the European Community name: title: Plant Director Michael Breumsø Signature: Date: 07/03/2006 48B9735 – rev.  © Danfoss A/S (AC-DSL / MWA), 06-2006 DKRCI.PI.KD0.A2.52 / 520H0745...
  • Page 8 22525 Hamburg, Germany References of Harmonised Standards used EN 0028-3 EN 023-3 EN 0222-4 References of other Technical Standards and Specifications used prEN 2284 DIN 358 AD-Merkblätter 2000 Authorised Person for the Manufacturer within the European Community Name: Michael Breumsø Title: Plant Director 07/03/2006 Signature: Date: 48B970 - rev. 2 DKRCI.PI.KD0.A2.52 / 520H0745 © Danfoss A/S (AC-DSL / MWA), 06-2006...

This manual is also suitable for:

Sva-st 20Sva-st 25Sva-st 40Sva-st 50Sva-st 65Sva-st 80 ... Show all