Installation manual 1 Safety Precautions • Servicing shall be carried out only by authorized personnel. • Only authorized spare parts, accessories and consumables shall be used. • Only use detergent intended for water-wash of textiles. Never use dry cleaning agents. •...
The machine/machines covered by this manual is/are made for commercial and industrial use only. 1.3 Copyright This manual is intended solely for consultation by the operator and can only be given to third parties with the permis- sion of Electrolux Professional AB company. 1.4 Symbols Caution...
Warranty will be applicable where the customer has used only genuine spare parts and has performed maintenance in accordance with Electrolux Professional AB user and maintenance documentation made available in paper or electronic format. Electrolux Professional AB strongly recommends using Electrolux Professional AB approved cleaning, rinse and des- caling agents to obtain optimal results and maintain product efficiency over time.
Installation manual 3 Technical data 3.1 Drawing fig.8025E Operating panel Detergent container Door opening, ⌀ 255 mm Cold water Hot water Drain pump Electrical connection 830* * Adjustable height: 25 mm.
Installation manual 3.2 Technical data Weight, net Drum volume litres Drum diameter Drum speed during wash 35/54 Drum speed during extraction 1450 G-factor, max. Heating: Electricity Frequency of the dynamic force 24.2 Floor load at max extraction 1.2±0.3 Sound power/pressure level at extraction* dB(A) 70/56 Sound power/pressure level at wash*...
Installation manual 4 Setup 4.1 Unpacking Remove the front panel by undoing the two screws on the bottom edge. Remove the rear panel by undoing the screws. Remove the three transport supports, one at the front and two at the back. Save the transport supports if the machine needs to be moved in the future.
Installation manual 4.2 Recycling instruction for packaging fig.X02404 Fig. Description Code Type Wrapping film LDPE 4 Plastics Corner protection PS 6 Plastics Cardboard packaging PAP 20 Paper Pallet FOR 50 Wood Screw FE 40 Steel FE 40 Steel Plastic bag PET 1 Plastics...
Installation manual 4.3 Siting Install the machine close to a floor drain or open drain. The machine should be positioned so that there is plenty of room for working, both for the user and service personnel. The figure shows minimum distance to a wall and/or other machines. Failure to respect the prescribed distances will prevent easy access for maintenance and service operations.
Installation manual 4.4 Mechanical installation If the machine is not to be mounted on a base the machine must be fastened to the floor. Mark and drill two holes (⌀ 8 mm) about 40 mm deep. fig.5358 Place the machine over the two drilled holes. The holes are at the front of the machine. Level the machine with the feet of the machine.
Installation manual 5 Water connection All water intake connections to the machine should be fitted with manual shut-off valves and filters, to facilitate instal- lation and servicing. Water pipes and hoses should be flushed clean before installation. The machine shall be connected with new water hoses. Re-used water hoses must not be used. Hoses are to be of an approved type and grade and comply with IEC 61770 and any applicable local regulations.
Installation manual 6 Water hardness and dosage Check the water hardness at your location and adjust the dosage according to the tables. The tables shows different dosage for different programs. A water hardness kit is available at Part No. 0S0586. With full lagoon load Water hardness range Water softener...
Installation manual 7 Connection of external dosing systems 7.1 Connection of the hoses The machine is prepared for connection of external dosing systems or water re-use systems etc. EDS, Efficient Dosing System: • Cut the top of the hose nipples to be used as showed in the figure. •...
Installation manual 7.2.1 Machine with connectors Connect the external dosing system to connections A and B on the machine. Connect the signal cable to B and the power supply to A. For Efficient dosing system the cables are delivered with the machine. Connect the power supply cable to the machine A and the other end of the cable together with the cable from Effi- cient Dosing in a connection box or with plug and receptacle.
Installation manual 7.2.2 Machine without connectors Connect the external dosing system to the I/O board, which is located to the right of the incoming power supply. The I/O board has edge connectors for connecting external dosing systems. Edge connectors on the I/O board can be loosened for connecting cables. 11 13 15 17 19 10 12 14 16...
Installation manual 7.2.3 Outputs Connect the power supply (e.g. 24V DC) for the external liquid supplies to 9 and 10. If an internal power supply (from the machine) is being used, it can be taken from 1 (N) and connected to 9 and from 2 (L) and connected to 10. Max load on the outputs 0.5 A.
Installation manual 7.2.4 Inputs The signal level can be 5-24V DC/AC or 100- 240V AC. For 5-24V, the signal reference is connected to 3 and for 100-240V to 4. Potentials on the inputs cannot be mixed. Note! The I/O board will be damaged if the voltage on connection 3 is too high > 24V. Connection 8 may be connected if the program is to pause, e.g.
Installation manual 8 Drain connection Drain pump The drainage pipe should be located over a floor drain, drainage channel or the like. The highest part of the drain hose shall be positioned according to the figure. Make sure there is no kinks in the hose. 100 mm 650 mm ±...
Installation manual 9.3 Machine connection The machine can be switched/reconnected to the following options. Connection option 380–415V/3N~ 4.4 kW Electric heated 301 / BN 302 / BK 303B / GY 303A / WT Connection option 380–415V/3~ 4.4 kW Electric heated 301 / BN 302 / BK 303B / GY...
Page 23
Installation manual Connection option 208–240V/1~ 2.2 kW 301 / BN Electric heated 302 / BK 303A / WT 303B / GY Connection option 208–240V/1N~ 2.2 kW 301 / BN Electric heated 302 / BK 303B / GY 303A / WT Connection option 100–240V/1N~ Non heated Connection option 100–240V/1~...
Installation manual 10 At first power up When the installation is complete and the power is connected for the first time you will be forced to make the following settings. When one setting is ready you will automatically enter the next one. •...
Installation manual 11 Function check May only be carried out by qualified personnel. A function check must be made when the installation is finished and before the machine can be ready to be used. Open the manual water valves. Start a program. •...
Installation manual 12 Disposal information 12.1 Disposal of appliance at end of life Before disposing of the machine, make sure to carefully check its physical condition, and in particular any parts of the structure that can give or break during scrapping. The machine’s parts must be disposed of in a differentiated way, according to their different characteristics (e.g.