This supplement contains information necessary to ensure the accuracy of the
above manuals.
© 2006 Fluke Corporation. All rights reserved. Printed in the U.S.A.
Manual Supplement
175, 177 & 179 Users
May 2003
Supplement Issue: 1
11/06
Page Count:
7
x

Advertisement

loading
Need help?

Need help?

Do you have a question about the 175 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Fluke 175

  • Page 1 Part Number: 2063257, 2063269, 2063233, 2063240 Issue Date: 11/06 Print Date: May 2003 Page Count: Revision/Date: This supplement contains information necessary to ensure the accuracy of the above manuals. © 2006 Fluke Corporation. All rights reserved. Printed in the U.S.A.
  • Page 2 175, 177 & 179 Users Manual Supplement Change #1, 36861, 38746 On page 2, under Terminals, replace Item 1 & 2 with the following: Input terminal for AC and DC milliamp measurements to 400 mA and frequency measurements. Input terminal for AC and DC current measurements to 10 A and frequency measurements.
  • Page 3 Manual Supplement 175, 177 & 179 Users On page 4, under MIN MAX AVG Recording Mode, replace the Note with following: Note For DC functions, accuracy is the specified accuracy of the measurement function ± 12 counts for changes longer than 350 ms in duration.
  • Page 4 175, 177 & 179 Users Manual Supplement On page 6, under Measuring AC and DC Voltage, replace the figure with the following: Volts AC Volts DC Millivolts DC HOLD MIN MAX RANGE HOLD MIN MAX RANGE HOLD MIN MAX RANGE AIK03F.eps...
  • Page 5 Manual Supplement 175, 177 & 179 Users On pages 11-14, replace the entire Specifications with the following: Specifications Accuracy is specified for 1 yr after calibration, at operating temperatures of 18 °C to 28 °C, with relative humidity at 0 % to 90 %. Accuracy specifications take the form of: ±...
  • Page 6 175, 177 & 179 Users Manual Supplement Accuracy ± ( [ % of Reading ] + [ Counts ] ) Function Range Resolution Model 175 Model 177 Model 179 0.1 mV 1.0 % + 3 1.0 % + 3 1.0 % + 3 600.0 mV...
  • Page 7 Manual Supplement 175, 177 & 179 Users Accuracy ± ( [ % of Reading ] + [ Counts ] ) Function Range Resolution Model 175 Model 177 Model 179 60.00 mA 0.01 mA 400.0 mA 0.1 mA DC Amps 1.0 % + 3 1.0 % + 3...
  • Page 8: Overload Protection

    175, 177 & 179 Users Manual Supplement Input Impedance Common Mode Rejection Ratio Function Overload Protection (Nominal) (1 kΩ Unbalanced) Normal Mode Rejection Volts AC 1000 V RMS > 10 MΩ < 100 pF > 60 dB @ DC, 50 Hz or 60 Hz...