TESTING A PEN

1. While observing the P
the tablet active area. A value for
number) should be displayed. If you have more than one tablet connected to your system, be sure you
have selected the T
2. Move your tool along the tablet surface. The X and Y D
position.
3. Test your Intuos4 pen switches. A tablet status LED should brighten each time you click with the tool
tip, press the side switch, or press the tool's eraser to the tablet.
Click on the tablet surface with the tool tip – the S
(P
should change from approximately 0% with no pressure applied to approximately 100%
RESSURE
when full pressure is applied.)
Press the side switch without pressing the tip to the tablet – the S
(For the Intuos4 pen, do this for both positions of the side switch.)
Pen
Airbrush
Press the tool's eraser to the tablet – the S
(Pressure should change from approximately 0% with no pressure applied to approximately 100%
when full pressure is applied.)
For the Airbrush, move the fingerwheel forward – the W
approximately 0 when the fingerwheel is all the way forward. Move the fingerwheel backward – the
W
value should increase to approximately 1000 when the fingerwheel is all the way back.
HEEL
4. Test tilt for the x-axis by moving the pen from a vertical position toward the right; the X T
change from approximately 0 to +60. Now move the tool to the left of vertical; the X T
change from approximately 0 to -60.
5. Test tilt for the y-axis by moving the pen from a vertical position toward the bottom of the tablet; the Y
T
value should change from approximately 0 to +60. Now move the tool toward the top of the tablet;
ILT
the Y T
value should change from approximately 0 to -60.
ILT
6. If you are testing an Art Pen, test pen rotation by holding the pen vertically and twisting it around its
axis. The displayed R
7. When you are done, click on the C
Contents
D
I
OINTING
EVICE
NFO
P
ROXIMITY
for which you are testing your tools from the T
ABLET
Tip = 1
Side switch (lower position) = 2
Side switch (upper position) = 3
Eraser = 1
Tip = 1
Side Switch = 2
Eraser = 1
value should change.
OTATION
button to exit the dialog box.
LOSE
Contents
Index
column, bring your Intuos4 tool within 10 mm (0.39 inch) of
, the D
N
, D
EVICE
AME
values should change to reflect the tool
ATA
state and P
WITCHES
state and P
WITCHES
HEEL
Index
T
, and a D
EVICE
YPE
EVICE
I
column.
ABLET
NFO
value should change.
RESSURE
state should change.
WITCHES
value should change.
RESSURE
value should decrease to a value of
67
S/N (serial
value should
ILT
value should
ILT
67