Setting The Time Range For Hourly Reports (#2619); Rs-232C Channel Assignment (#2690) - Sharp ER-A440 Instruction Manual

Instruction manual
Hide thumbs Also See for ER-A440:
Table of Contents

Advertisement

Setting the time range for hourly reports
You can set the time range for an hourly report .
Procedure
.
2619
*A: Time range
To set the time range to 30 minutes (in the 24-hour system), enter 0.
To set the time range to 60 minutes (in the 24-hour system), enter 1.
BC: Starting time (hour = 00 to 23)
Example
Note
To perform this setting, an hourly Z report (# 160) must be done.
RS-232C channel assignment
Your machine is equipped with an RS-232C interface. If you use the on-line communication function, the
channel number of the RS-232C interface must be programmed by using the following procedure.
To realize the on-line communication, consult your dealer.
Procedure
.
2690
*P: 1
**
Item:
A
For the ON-LINE communication
B to D
Always enter 0.
*P: 2 and 3 (ABCD: Not used. Always enter 0.)
Example
62
When A through C are all zeros
*
ABC
Key operation
. ≈
2619
107
When A through D are all zeroes
*P
1 to 3
Key operation
. ≈
2690
≈ :
1
PGM 2
;
;
2690
PGM 2
:
**ABCD
Selection:
Disable
Enable (enter the channel number)
;
2619
Print
;
Print
Entry:
0
8
0
P
A through D

Hide quick links: