Download Print this page
Dometic Cuddy II Installation And Operation Manual
Dometic Cuddy II Installation And Operation Manual

Dometic Cuddy II Installation And Operation Manual

Self-contained dc air conditioner

Advertisement

Quick Links

Cuddy II Self-contained DC Air Conditioner
Installation and Operation Manual
M
CDB3.5
ODEL
Dometic Group Marine Division
Rev. 20141120
L-3397 English
P/N 337786
COPYRIGHT © 2011-2014 Dometic Group Marine Division. All Rights Reserved.
No part of this publication may be reproduced, translated, stored in a retrieval system, or transmitted in any form or by any means
electronic, mechanical, photocopying, recording or otherwise without prior written consent by Dometic Marine. Every precaution has
been taken in the preparation of this manual to insure its accuracy. However, Dometic Marine assumes no responsibility for errors
and omission. Neither is any liability assumed for damages resulting from the use of this product and information contained herein.

Advertisement

loading
Need help?

Need help?

Do you have a question about the Cuddy II and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Dometic Cuddy II

  • Page 1 Dometic Marine. Every precaution has been taken in the preparation of this manual to insure its accuracy. However, Dometic Marine assumes no responsibility for errors and omission. Neither is any liability assumed for damages resulting from the use of this product and information contained herein.
  • Page 2: Table Of Contents

    Table of Contents SAFETY ........1 .
  • Page 3: Safety

    SAFETY Cuddy II DC Air Conditioner Installation and Operation Manual SAFETY This safety alert symbol appears with most safety statements. It means attention, become alert, your safety is involved! Please read and abide by the message that follows the safety alert symbol.
  • Page 4: An And Seawater Strainer

    During the day, it may be closed should you like more air directed to the main living area. Consult with your local Dometic Marine service representative if you are unsure which is the main supply grille on your boat.
  • Page 5: Seawater Pump

    These can clog strainers and water pumps every hour to hour and a half in some cases. In such severe conditions, seek the advice of your local factory service representative. They will be most familiar with solutions to localized situations. Dometic works closely with its servicing dealers when custom solutions are required.
  • Page 6: General Description

    (return) air temperature, and the humidity of the inlet (return) air. Please consult your Dometic Marine dealer or the factory if you have a question about the operation of your air conditioner.
  • Page 7: Installation Requirements

    Dometic self-contained air conditioners do NOT meet Federal requirements for ignition protection. NEVER install the Dometic air conditioner in an engine room, the bilge, or any areas where it may introduce deadly or noxious vapors into the boat's living space. NEVER install the unit in any room or compartment that contains an internal combustion engine, fuel tanks, LPG/CPG cylinders, regulators, valves, or fuel line fittings.
  • Page 8: Ounting Of The Condensate Drains

    However, the breaker must be sized for both the water pump and the Dometic unit. A separate breaker is required for the water pump if multiple Dometic units are installed.
  • Page 9: Fresh

    YSTEM Proper water flow is absolutely critical to the operation of the Dometic air conditioner. If the pipe is too small, back pressure is created, causing a drop in water flow, even if the pump is correctly sized. If the piping is too large, the slow velocity of the water may cause silt build-up and barnacle growth inside the piping, eventually restricting water flow.
  • Page 10: Duct Work Guidelines

    The return air grille must have sufficient open air to permit adequate air to the indoor coil. The Dometic air conditioner has a factory provided filter located in front of the air coil. If a return air filter grille is used, it is recommended that the filter on the unit be removed.
  • Page 11: Air Flow Noise

    Larger ducts will have less friction and less noise. THERMOSTATS AND CONTROLLERS CDB3.5 The CDB3.5 can be controlled by either the o-LED display or the Dometic 222130206 thermostat. Before setting up either thermostat or display: Turn the seacock valve to the open position, and Turn on the water pump.
  • Page 12: Joystick Operation

    THERMOSTATS AND CONTROLLERS Cuddy II DC Air Conditioner Installation and Operation Manual OYSTICK OPERATION The four position joystick may be tapped up, down, right, left, or in the center to make changes to the operation of the control. PERATING ODES...
  • Page 13: Moisture Mode

    THERMOSTATS AND CONTROLLERS Cuddy II DC Air Conditioner Installation and Operation Manual OISTURE Select this mode to help control humidity in the room while the room is unoccupied. The control will operate in cooling mode for up to 1 hour every 6 hours.
  • Page 14: Entering The Program M Parameter Description

    THERMOSTATS AND CONTROLLERS Cuddy II DC Air Conditioner Installation and Operation Manual ARAMETER ESCRIPTION • Cycled fan: When this parameter is set for "Cycled" and the display is in the ON mode, the fan will operate on whenever the compressor is running. When set for "Continuous", the fan will always operate when the system is in the ON mode.
  • Page 15: Specifications

    THERMOSTATS AND CONTROLLERS Cuddy II DC Air Conditioner Installation and Operation Manual Figure 6: MasterFlux Wiring Diagram PECIFICATIONS Set point range 55°F to 85°F (12.7°C to 29.4°C) Ambient temperature range displayed 5°F to 150°F Sensor accuracy +/-2°F at 77°F Line high voltage limit...
  • Page 16: Operating And Configuring The Thermostat

    THERMOSTATS AND CONTROLLERS Cuddy II DC Air Conditioner Installation and Operation Manual 222130206 T PERATING AND ONFIGURING THE HERMOSTAT WARNING Always disconnect the power to the system before installing, removing or cleaning the thermostat. PERATION The display indicates room temperature and the word ROOM is shown on the LCD. When in cool mode and the temperature selector is pressed, the display temporarily indicates the setpoint temperature and the word SET is shown on the LCD.
  • Page 17: Installation

    THERMOSTATS AND CONTROLLERS Cuddy II DC Air Conditioner Installation and Operation Manual NSTALLATION WARNING Always disconnect the power to the system before installing, removing or cleaning the thermostat. These instructions are provided for the proper mounting of the thermostat itself. An Operation Chart is provided to show thermostat capabilities.
  • Page 18 THERMOSTATS AND CONTROLLERS Cuddy II DC Air Conditioner Installation and Operation Manual ONFIGURATION ETTINGS The setup screens for Configuration Mode are as follows: Temperature Scale (F or C) - Choose Fahrenheit or Celsius. Press the UP or DOWN button to select.
  • Page 19: Configuration Mode Settings Specifications

    THERMOSTATS AND CONTROLLERS Cuddy II DC Air Conditioner Installation and Operation Manual PECIFICATIONS Model Capacity (BTU/hr) 3.5k Voltage (VDC) Min. Voltage (VDC) 10.5 Max. Voltage (VDC) Full Load Amps (FLA) cool 29.2 Blower (FLA) DC Power Requirement (W) Max. Circuit Breaker (Amps) Min.
  • Page 20: Start-Up

    START-UP Cuddy II DC Air Conditioner Installation and Operation Manual START-UP CAUTION Always exercise care when working around operating equipment. Certain components operate at fairly high temperatures. Do not touch operating machinery without the aid of qualified personnel as stated above.
  • Page 21: Boat Is Out Of Water In Dry When The Boat I S Put Bthe Spring

    WINTERIZING THE SYSTEM Cuddy II DC Air Conditioner Installation and Operation Manual OAT IS UT OF ATER IN With the boat out of the water: Open the seacock to permit all the water to drain out of system via the thru-hull fitting.
  • Page 22: Troubleshooting

    TROUBLESHOOTING Cuddy II DC Air Conditioner Installation and Operation Manual TROUBLESHOOTING CDB3.5 A ROUBLESHOOTING THE ONDITIONER CAUTION Always exercise care when working around operating equipment. Certain components operate at fairly high temperatures. Do not touch operating machinery without the aid of qualified personnel as stated above.
  • Page 23 TROUBLESHOOTING Cuddy II DC Air Conditioner Installation and Operation Manual PROBLEM POSSIBLE REASONS SOLUTIONS Compressor runs, but blower 1. Blower motor 1. Check for electrical shorts, ground, and open circuits. will not run Replace blower motor if it is defective.
  • Page 24 TROUBLESHOOTING Cuddy II DC Air Conditioner Installation and Operation Manual PROBLEM POSSIBLE REASONS SOLUTIONS Loud operation 1. Copper tubing is vibrating 1. Adjust by bending slightly to a more stable position. Separate any tubing that is making contact with other tubing or components.
  • Page 25: Wiring Diagrams

    WIRING DIAGRAMS Cuddy II DC Air Conditioner Installation and Operation Manual WIRING DIAGRAMS L-3397 ENGLISH...
  • Page 26 WIRING DIAGRAMS Cuddy II DC Air Conditioner Installation and Operation Manual L-3397 ENGLISH...
  • Page 27: Ectioni - What Covered

    Dometic reserves the right to improve its products, through changes in design or material without being obligated to incorporate such changes in products of prior manufacture. Dometic can make changes at any time in design, materials, or part of units of any one, model year, without obligation or liability to owners of units of the same year's model of prior manufacture.
  • Page 28: Section Iii - Coverage Period Section Iv - Getting Service

    However, based on the date the equipment is first put in service, the item may still be covered by the Dometic warranty as described in Section I. For proof of date put in service, Dometic will require a copy of the bill of sale of the Dometic equipment from the installer or new boat dealer to the original owner.
  • Page 29: Table Of Warranty Periods

    Cuddy II DC Air Conditioner Installation and Operation Manual Third option: The customer may send his equipment back to the factory to have the repair work done. Dometic will make every effort to return the equipment to the customer within a three week time period. If the claim represents a legitimate warranty problem, Dometic will pay the freight both ways.
  • Page 30 NOTES...
  • Page 31 NOTES...

This manual is also suitable for:

Cdb3.5