Page 3
All product and brand names are the service marks, trademarks, registered trademarks, or registered service marks of their respective owners. Printed in the United States of America. Honeywell reserves the right to change any information in this document at any time without prior notice.
DO NOT ACCEPT VERBAL APPROVALS, THEY ARE NOT VALID. Honeywell never recommends using the PW-5000 Series or related products as a primary warning or monitoring system. Primary warning or monitoring systems should always meet local fire and safety code requirements. The installer must also test the system on a regular basis by instructing the end user in appropriate daily testing procedures.
Customer harmless for any costs or damages including reasonable attorneys’ fees which Customer may be required to pay as a result of the defective Product or the negligence of Honeywell, its agents, or its employees.
Front Matter Compliance Customer shall hold harmless and indemnify Honeywell from and against all claims, demands, losses and liability arising out of damage to property or injury to persons occasioned by or in connection with the acts or omissions of Customer and its agents and employees, and from and against all claims, demands, losses and liability for costs of fees, including reasonable attorneys’...
All Products sold or licensed by Honeywell include a warranty registration card which must be completed and returned to Honeywell by or on behalf of the end user in order for Honeywell to provide warranty service, repair, credit or exchange. All warranty...
Confidentiality All software, drawings, diagrams, specifications, catalogs, literature, manuals and other materials furnished by Honeywell relating to the design, use and service of the Products shall remain confidential and shall constitute proprietary rights of Honeywell, and Customer agrees to treat such information as confidential. Customer...
Page 12
Front Matter Confidentiality www.honeywell.com...
Installing the PW-5000 Remote Enclosure Description The PW-5000 Remote Enclosure allows for a variety of system configurations. It can be used in combination with the PW5K2ENC1, for example, to place modules closer to the doors they control. Or it can be used alone to house modules for a smaller system.
• Requires 230VAC/50 60Hz input 24 VDC 2.5A output CE certified AC-DC power supply. • The recommends Honeywell part number is PSX220LPS. • Maximum battery charge current 0.3A. • AC on LED. • AC Fail supervision. • Low Battery Supervision (form “C” contacts).
Installing the PW-5000 Remote Enclosure LED Diagnostics Table 1 LED Diagnostics AC LED DC LED Description Normal operating conditions Loss of AC, standby battery supplying power No DC output Loss of AC, discharged or no standby battery, no DC output PW-5000 Remote Enclosure Installation Guide, Document 800-06955V1, Revision C...
• Replace the 12V 4 amp hour battery every 2 to 2.5 years. • Oil the hinges on the door every 12 months. Operating Parameters • Temperature: 35 F to 110 F (2 C to 43 • Operating Humidity: up to 85% non-condensing www.honeywell.com...
See individual panel wiring diagrams supplied with the panels. 12. Connect the green and yellow Tamper Switch wires to the appropriate inputs on the panels. See individual panel wiring diagrams supplied with the panels. 13. Connect Communications wiring per the wiring diagram supplied with the panels. www.honeywell.com...
14. Attach the red battery charging connection to the positive terminal of the battery. The negative connection is connected at the factory. Check all connections prior to powering up the enclosure and panels Installation Diagram 1 Installation Diagram 2 www.honeywell.com...