General Installation Instructions
These instructions should be read carefully prior to any installation and retained after completion for further reference and maintenance.
Please give these instructions to the building owner/occupier after installation.
Important Safety
1.
Before installation, maintenance or lamp replacement, ensure that the mains supply to the luminaire is switched off and
the circuit supply fuses are removed or the circuit breaker is turned off.
2.
It is recommended that only a qualified electrical contractor carries out the installation of this luminaire and that the
luminaire is installed in compliance with the current edition of the IEE Wiring Regulations and Building Regulations.
3.
The person carrying out the installation is to check and verify that the total load on the circuit, including that of this
luminaire does not exceed the rating of the circuit cable, fuse or circuit breaker.
4.
Where a luminaire incorporates discharge control gear (inductive load), the circuit capacity and ratings require careful
sizing to avoid nuisance tripping of the protective device used in the installation.
5.
Where applicable, careful consideration should be taken during installation to ensure that all fixings and/or suspensions
are of a suitable size for the luminaire being installed.
Ratings
1. All luminaires are manufactured & tested in compliance with the requirement contained within BS EN 60598 and are CE marked.
2. All luminaires that are of Class 1 construction and that are marked accordingly, MUST be earthed.
3. All luminaires are designed to operate at 230Volts AC -6%/+10% = 216Volts to 252Volts. Do not operate outside these voltages.
4. All luminaires are only suitable for applications within their rated Ingress Protection limits as stated.
5. This luminaire is intended for internal use only
Exclusions to Warranty
Please Note - The limited warranty shall be null and void in the following circumstances:-
Failure by the installer, end user or any third party to exercise caution to protect any covered product or part from outside damage, adverse temperature (normal operating
ambient temperature 0 - 40°C), humidity conditions, fluctuations in the electrical system or physical abuse as well as failure related to workmanship in the installation of
the products or parts.
-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Installation
Turn off power supply.
Remove the plastic grub screw located in the centre of the front LED assembly using a small flat/pozi headed screwdriver,
Pull the spine and front LED assembly apart.
Disconnect the LED PCB connectors and retaining cords.
Select a suitable location to mount the luminaire spine using the fixings supplied.
Please note this luminaire should not be installed in locations close to any heat source.
Feed the incoming supply cable through into the luminaire spine at the desired entry point at the rear of the fixture.
Connect the mains supply to supply terminals.
Please see connections below taking care to observe polarity.
Connect as follows:-
Once connected offer the front assembly up to the spine, attach the retaining cords to the front assembly.
Re-connect the male / female connectors from the LED driver to the LED board(s).
Locate the front assembly and fix back onto the spine.
Replace the plastic grub screw and secure.
Restore power supply, switch on and test for satisfactory operation.
Warning
Failure to comply with these instructions may result in irreparable damage to the control gear.
This product must not be modified in any way as this will negate any Safety approvals, and may render the product inoperable or unsafe. The product must be
installed in accordance with the instructions.
----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Disposal of Electronic Equipment WEEE Directive 2002/96/EC
This product falls within the scope of the Waste Electrical & Electronic Equipment Directive (WEEE),
which means the product should not be disposed of as normal household waste. Ensure that this
luminaire and lamp is disposed of in accordance with the WEEE Directive. Contact a local Council Waste
Dept. Local Amenity Site, or the Environment Agency for further information. RoHS - All components and
materials used in this product are RoHS 2002/95/EC compliant.
Page No. 1 Ansell Electrical Products, Unit 6B, Stonecross Ind. Park, Yew Tree Way, Warrington, WA3 3JD
Description – Topline 6 LED Batten with Emergency
Installation Instructions
®
Luminaire Code(s) –
LIVE
(L1)
LIVE
(L2)
NEUTRAL
(N)
EARTH
ATLLED/M3
BROWN OR RED
(switched)
BROWN OR RED
(un-switched)
BLUE OR BLACK
GREEN / YELLOW
www.anselluk.com
Need help?
Do you have a question about the ATLLED/M3 and is the answer not in the manual?
Questions and answers