General Installation Instructions
These instructions should be read carefully prior to any installation and retained after completion for further reference and maintenance. Please give
these instructions to the building owner/occupier after installation.
Important Safety
1.
Before installation, maintenance or lamp replacement, ensure that the mains supply to the luminaire is switched off and the
circuit supply fuses are removed or the circuit breaker is turned off.
2.
It is recommended that only a qualified electrical contractor carries out the installation of this luminaire and that the luminaire
is installed in compliance with the current edition of the IEE Wiring Regulations.
3.
The person carrying out the installation is to check and verify that the total load on the circuit, including that of this luminaire
does not exceed the rating of the circuit cable, fuse or circuit breaker.
4.
Where a luminaire incorporates discharge control gear (inductive load), the circuit capacity and ratings require careful sizing
to avoid nuisance tripping of the protective device used in the installation.
5.
Where applicable, careful consideration should be taken during installation to ensure that all fixings and/or suspensions are of
a suitable size for the luminaire being installed.
Ratings
1.
All luminaires are manufactured & tested in compliance with the requirement contained within BS EN 60598 and are CE marked.
2.
All luminaires that are of Class 1 construction and that are marked accordingly, MUST be earthed.
3.
All tracks are designed to operate at 230Volts AC +10% / -6% = 216Volts to 252Volts. Do not operate outside these voltages.
4.
All luminaires are only suitable for applications within their rated Ingress Protection limits as stated.
5.
For internal use ONLY
Exclusions to Warranty
Please Note - The limited warranty shall be null and void in the following circumstances:-
Failure by the installer, end user or any third party to exercise caution to protect any covered product or part from outside damage, adverse temperature (normal operating ambient
temperature 0 - 25°C), humidity conditions, fluctuations in the electrical system or physical abuse as well as failure related to workmanship in the installation of the products or parts.
-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Installation
Remove the fitting and framed diffuser from the packaging.
Remove the eight screws that retain the framed diffuser in place.
This fitting must be connected directly to a Mains Voltage supply.
Remove the 2 retaining screws and open the hinged gear tray, Terminate the supply cable into the terminal block mounted inside the base of the fitting, having first passed it
through the designated hole in the side of the luminaire, ensuring correct polarity is observed and that the luminaire is earthed.
This luminaire is suitable for both suspended and plasterboard ceilings. Verify suitability with the ceiling manufacturer.
For Plasterboard Ceiling installation, cut out a square hole 577mm x 577mm.
Offer the luminaire through the plasterboard ceiling and secure by tightening the Easy Fix Brackets attached.
Replace the framed diffuser into the fitting making sure that it is perfectly aligned taking care not to damage the neoprene gasket seal. Failure to do this may harm the
Ingress Protection of this fitting.
Do not under any circumstances install insulating or other material over the top of this luminaire.
Connect as follows:-
Connect the battery leads. The battery pack is not connected for safety reasons during transit. Do not leave in emergency mode for prolonged periods over 12hrs. This
can lead to irreparable damage to the battery pack.
Restore power supply, switch on and test for satisfactory operation.
A 48 hour period is required for battery to charge fully.
Warning
Failure to comply with these instructions may result in irreparable damage to the control gear.
This product must not be modified in any way as this will negate any Safety approvals, and may render the product inoperable or unsafe. The product
must be installed in accordance with the instructions.
--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Maintenance:
1. If replacing the LED Driver, please ensure the drivers secondary output / wattage is correct matching, that of the existing LED driver.
Disposal of Electronic Equipment WEEE Directive 2002/96/EC
This product falls within the scope of the Waste Electrical & Electronic Equipment Directive
(WEEE), which means the product should not be disposed of as normal household waste.
Ensure that this luminaire and lamp is disposed of in accordance with the WEEE Directive.
Contact a local Council Waste Dept. Local Amenity Site, or the Environment Agency for
further information. RoHS - All components and materials used in this product are RoHS
2002/95/EC compliant.
--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Ansell Lighting Products, Unit 6B, Stonecross Ind. Park, Yew Tree Way, Warrington, WA3 3JD
Description – Defender LED IP65 Clean Air
Installation Instructions
®
Luminaire Code(s) –
LIVE
LIVE
NEUTRAL
EARTH
Recessed Modular with Emergency
ADELED/M3
(L1)
BROWN OR RED (Permanent)
(L)
BROWN OR RED (switched)
(N)
BLUE OR BLACK
(
)
GREEN & YELLOW
www.anselluk.com

Advertisement

loading
Need help?

Need help?

Do you have a question about the ADELED/M3 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Ansell ADELED/M3

  • Page 1 Contact a local Council Waste Dept. Local Amenity Site, or the Environment Agency for further information. RoHS - All components and materials used in this product are RoHS 2002/95/EC compliant. -------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- www.anselluk.com Ansell Lighting Products, Unit 6B, Stonecross Ind. Park, Yew Tree Way, Warrington, WA3 3JD...
  • Page 2 Contact a local Council Waste Dept. Local Amenity Site, or the Environment Agency for further information. RoHS - All components and materials used in this product are RoHS 2002/95/EC compliant. ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- www.anselluk.com Ansell Lighting Products, Unit 6B, Stonecross Ind. Park, Yew Tree Way, Warrington, WA3 3JD...