SCALANCE XCB-000 SMART Introduction Safety notes SIMATIC NET Description Installing Industry Ethernet Switches SCALANCE XCB-000 SMART Connecting Maintenance and troubleshooting Operating Instructions Technical specifications Dimension drawings Certifications and approvals Order numbers 10/2024 A5E53692567-AA...
Page 2
Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
Page 4
Table of contents Dimension drawings of the SCALANCE XCB016 SMART ............39 Certifications and approvals ........................ 41 Order numbers............................. 43 Index ..............................45 SCALANCE XCB-000 SMART Operating Instructions, 10/2024, A5E53692567-AA...
Page 5
Ethernet / PROFINET passive network components", you will find information on other SIMATIC NET products that you can operate along with the devices of this product line in an Industrial Ethernet network. You can find the system manuals on Siemens Industry Online Support: • SIMATIC NET: Industrial Ethernet/PROFINET Industrial Ethernet (https://support.industry.siemens.com/cs/ww/en/view/27069465) •...
Page 6
The figure shows an example of an ID link for the SCALANCE XCB016 SMART. Device defective In the event of a fault, send the device to your Siemens representative for repair. Repairs on- site are not possible. Recycling and disposal The products are low in pollutants, can be recycled and meet the requirements of the WEEE directive 2012/19/EU for the disposal of electrical and electronic equipment.
Page 7
Siemens’ products and solutions undergo continuous development to make them more secure. Siemens strongly recommends that product updates are applied as soon as they are available and that the latest product versions are used. Use of product versions that are no longer supported, and failure to apply the latest updates may increase customer’s exposure to...
Page 8
Safety notes 2.2 Safety notices Safety notices Read the safety notices Note the following safety notices. These relate to the entire working life of the device. You should also read the safety notices relating to handling in the individual sections, particularly in the sections "Installation"...
Page 9
Description Product overview The IE switches of the SCALANCE XCB-000 SMART product line allow the cost-effective installation of Industrial Ethernet bus and star structures with switching functionality. Note It is not possible to use IE switches of the SCALANCE XCB-000 product line in a redundant ring because they do not support redundancy.
Page 10
Description 3.1 Product overview XCB004 SMART XCB016 SMART TP (RJ-45) Gigabit Ethernet 10 / 100 / 1000 Mbps Fiber multimode (SC) Gigabit Ethernet 1000 Mbps Fiber single mode (SC) Gigabit Ethernet 1000 Mbps Unpacking and checking WARNING Do not use any parts that show evidence of damage If you use damaged parts, there is no guarantee that the device will function according to the specification.
Page 11
Description 3.2 Device view Device view 3.2.1 SCALANCE XCB004 SMART SCALANCE XCB004 SMART has four RJ-45 jacks for the connection of end devices or other network segments. SCALANCE XCB-000 SMART Operating Instructions, 10/2024, A5E53692567-AA...
Page 12
Description 3.3 Network topologies 3.2.2 SCALANCE XCB016 SMART SCALANCE XCB016 SMART has 16 RJ-45 jacks for the connection of end devices or other network segments. Network topologies Switching technology allows extensive networks to be set up with numerous nodes and simplifies network expansion.
Page 13
Description 3.3 Network topologies Star topology The following figures show the examples of SCALANCE XCB-000 SMART devices star topologies. SCALANCE XCB-000 SMART Operating Instructions, 10/2024, A5E53692567-AA...
Page 14
Description 3.4 TP (Twisted pair) ports TP (Twisted pair) ports Note Strain relief for the Ethernet cables In order to avoid mechanical stress on the Ethernet cables and resulting interruption of the contact, fasten the cables at a short distance from the connector using a cable guide or busbar.
Page 15
Description 3.4 TP (Twisted pair) ports 3.4.2 Functions Auto-negotiation With the auto-negotiation mechanism, repeaters and end devices can automatically determine the transmission speed and the transmission mode of the partner port. This makes it possible to configure different devices automatically. Two components connected to a link segment can exchange information about the data transfer and can adapt their settings to each other.
Page 16
Description 3.4 TP (Twisted pair) ports 3.4.3 Insulation between the TP ports The insulation between the TP ports is based on the number of TP ports. SCALANCE XCB004 SMART There are two TP port groups: • Group 1: P1 and P4 •...
Page 17
Description 3.5 LED display LED display Power LED 'L' The power LED shows the status of the power supply. Device LED color LED status Meaning SCALANCE XCB-000 Green Power supply is connected SMART Power supply is not connected or the applied voltage is too low.
Page 18
Installing Safety notices When installing the device, keep to the safety notices listed below. WARNING If the cable or conduit entry point exceeds 70 °C or the branching point of conductors exceeds 60 °C, special precautions must be taken. If the equipment is operated in an air ambient in excess of 40 ℃, only use cables with admitted maximum operating temperature of at least 80 ℃.
Page 19
Installing 4.2 DIN rail mounting Keep to the minimum clearances so that the convection ventilation of the device is not blocked. • Below at least 10 cm • Above at least 10 cm Installation position SCALANCE XCB-000 SMART devices support horizontal and vertical installation position. Horizontal installation position is recommended.
Page 20
Installing 4.2 DIN rail mounting Follow these steps to install SCALANCE XCB004 SMART on a DIN rail. 1. Hook the back of the device onto the DIN rail. 2. Press on the lower part of the device to snap the clip on the DIN rail.
Page 21
Installing 4.2 DIN rail mounting Mounting SCALANCE XCB016 SMART Follow these steps to install SCALANCE XCB016 SMART on a 35 mm DIN rail. 1. Place the device and hook the rail clip on the upper edge of the DIN rail. 2.
Page 22
Installing 4.3 Wall mounting Wall mounting Fasten securely WARNING Personal injuries or material damage in the case of insufficient load-bearing capacity of wall The device could fall if the wall to which it is mounted has insufficient load-bearing capacity. This can result in personal injuries or material damage. Ensure that the mounting surface on the wall can bear four times the total weight of the device, including elements.
Page 23
Installing 4.3 Wall mounting Follow these steps to mount the device on the wall. 1. Pull out the two rail clips on the rear of the device. ① Rail clip Note When you do not wall-mount SCALANCE XCB004 SMART devices, always keep the rail clips in the factory default position, that is, the locked (inner) position.
Page 24
Connecting When connecting up the device, keep to the following safety notices. WARNING Power supply The device is designed for operation with a directly connectable Safety Extra Low Voltage (SELV) or Protective Extra Low Voltage (PELV). Only Safety Extra Low Voltage (SELV) or Protective Extra Low Voltage (PELV) complying with IEC/EN/DIN EN IEC 61010-2-201 can be connected to the power supply terminals.
Page 25
Connecting 5.2 Grounding Note Wire end ferrules Use crimp shapes with smooth surfaces, such as provided by square and trapeze shaped crimp cross sections. Crimp shapes with wave-shaped profile are unsuitable. Grounding The connection of the reference potential surface with the functional earth system is normally in the cabinet close to the power feed-in.
Page 26
Connecting 5.3 Power supply To remove the grounding cable from the terminal block, use a screwdriver to press down on the corresponding groove on the bottom of the terminal block, until the cable can be pulled out of the terminal block. Power supply The power supply is connected via a plug-in terminal block with three terminals on the underside of the SCALANCE XCB-000 SMART devices.
Page 27
Connecting 5.3 Power supply Position and assignment The following figure shows the position of the power supply and the assignment of the terminal block using SCALANCE XCB004 SMART as an example. Contact Assignment Pin 1 Functional ground Pin 2 M (Power supply negative) Pin 3 L+ (24 V DC) WARNING...
Page 28
Connecting 5.4 Twisted pair cable Procedure 1. Unplug the terminal block from the device. 2. Plug power cables separately into Pin 2 and Pin 3 of the terminal block until the cables lock in place. 3. Insert the terminal block into the sockets on the bottom of the device. To remove the power cables from the terminal block, use a screwdriver to press down the corresponding grooves on the bottom of the terminal block, until the cables can be pulled out of the terminal block.
Page 29
Connecting 5.5 IE FC RJ-45 Plug 180 Plugging in the IE FC RJ45 Plug 180 Plug the IE FC RJ45 Plug 180 into the twisted-pair port of the device until it locks in place. When using Ethernet cables with IE FastConnect RJ-45 plugs on devices without securing collars, the cables must be supported on a cable guide close to the device.
Page 30
A power supply of at least 19.2 V is necessary for normal operation. Device defective If a fault develops, please send the device to your Siemens service center for repair. Repairs on-site are not possible. SCALANCE XCB-000 SMART...
Page 31
Technical specifications Technical specifications of the SCALANCE XCB004 SMART Technical specifications Article number SCALANCE XCB004 SMART 6GK5004-0BA00-1AB2 Attachment to Industrial Ethernet Quantity Design RJ-45 jacks with MDI-X pinning Properties Half / full duplex Transmission rate 10/100 Mbps Permitted cable lengths (Industrial Alternative combinations per length range Ethernet) 0 to 55 m...
Page 32
Technical specifications 7.1 Technical specifications of the SCALANCE XCB004 SMART Technical specifications Operating altitude During operation • ≤ 2,000 m above sea level at max. +60 °C ambi- ent temperature • < 3,000 m above sea level at max. +55 °C ambi- ent temperature •...
Page 33
Technical specifications 7.2 Technical specifications of the SCALANCE XCB016 SMART Technical specifications of the SCALANCE XCB016 SMART Technical specifications Article number SCALANCE XCB016 SMART 6GK5016-0BA00-1QB2 Attachment to Industrial Ethernet Quantity Design RJ-45 jacks with MDI-X pinning Properties Half / full duplex Transmission rate 10/100 Mbps Permitted cable lengths (Industrial...
Page 34
Technical specifications 7.3 Switching properties Technical specifications Pollution degree MTBF (EN/IEC 61709; 40 °C) 310.37 years Housing material Polycarbonate (plastic) Weight 242 g (with terminal block) Dimensions (W x H x D) 40 x 140 x 97.5 mm Installation options Mounting on a DIN rail Switching properties Note the following switching properties:...
Page 35
Technical specifications 7.4 Mechanical stability (in operation) Mechanical stability (in operation) Note the following mechanical stability when the device is in operation: Device DIN EN/IEC 60068-2-8 vibration DIN EN/IEC 60068-2-27 shock 5 - 8.4 Hz: 7.0 mm 150 m/s , 11 ms duration 8.4 - 150 Hz: 10 m/s 6 shocks per axis 1 oct/min, 20 sweeps...
Page 36
Dimension drawings Note Dimensions are specified in mm. Dimension drawings of the SCALANCE XCB004 SMART Front view SCALANCE XCB-000 SMART Operating Instructions, 10/2024, A5E53692567-AA...
Page 37
Dimension drawings 8.1 Dimension drawings of the SCALANCE XCB004 SMART Side view SCALANCE XCB-000 SMART Operating Instructions, 10/2024, A5E53692567-AA...
Page 39
Dimension drawings 8.2 Dimension drawings of the SCALANCE XCB016 SMART Dimension drawings of the SCALANCE XCB016 SMART Front view SCALANCE XCB-000 SMART Operating Instructions, 10/2024, A5E53692567-AA...
Page 40
Dimension drawings 8.2 Dimension drawings of the SCALANCE XCB016 SMART Side view SCALANCE XCB-000 SMART Operating Instructions, 10/2024, A5E53692567-AA...
Page 41
You can check which of the following approvals have been granted for your product by the markings on the type plate. You can find the current approvals for the product on Siemens Industry Online Support (https://support.industry.siemens.com/cs/cn/en/ps/29329/cert). Notes for the manufacturers of machines This product is not a machine in the sense of the EC Machinery Directive.
Page 42
Certifications and approvals You will find the EC declaration of conformity for these products on the Internet pages of Siemens Industry Online Support (https://support.industry.siemens.com/cs/cn/en/ps/29329/cert). The EC Declaration of Conformity is available for all responsible authorities at: Siemens Aktiengesellschaft Digital Industries...
Page 43
Order numbers SCALANCE XCB-000 SMART The following table lists the order numbers of SCALANCE XCB-000 SMART products and the power supply terminal block. Device Order number SCALANCE XCB004 SMART 6GK5004-0BA00-1AB2 SCALANCE XCB016 SMART 6GK5016-0BA00-1QB2 Power supply terminal block 6GK5980-1CB10-0BA5 Accessories The following table lists the order numbers of all other products that can be used together with SCALANCE XCB-000 SMART devices.
Page 44
Order numbers Component Length Packaging Order number Suitable for unit SCALANCE XCB-000 SMART Fast Ethernet IE FC RJ-45 Plug 180 2x2 6GK1901-1BB10-2AA0 IE FC RJ-45 Plug 4x2 6GK1901-1BB11-2AA0 IE FC RJ-45 Plug 180 2x2 6GK1901-1BB10-2AB0 IE FC RJ-45 Plug 4x2 6GK1901-1BB11-2AB0 IE FC RJ-45 Plug 180 2x2 6GK1901-1BB10-2AE0...
Page 45
Index Accessories, 43 LED display, 30 Approvals, 41, 41 Port LEDs, 17 Article number, 5 Power LED, 17 Auto polarity exchange, 15 Autonegotiation, 15 MDI/MDIX auto-crossover function, 15 Mechanical stability, 35 CE mark, 41 Mounting, 18 installation type, 18 defective, 30 Digital nameplate, 6 Network topology, 12 DIN rail mounting, 19...