Page 1
Ultrasonic Anemometer 3D Short - Instruction for Use 4.383x.xx.xxx from Software version V3.20 Dok. No. 021950/11/21 T H E W O R L D O F W E A T H E R D A T A...
Page 2
Safety Instructions • Before operating with or at the device/product, read through the operating instructions. This manual contains instructions which should be followed on mounting, start-up, and operation. A non-observance might cause: - failure of important functions - endangerment of persons by electrical or mechanical effect - damage to objects •...
Short instructions for use These operating instructions describe the installation of the instrument. The Ultrasonic Anemometer 3D is factory-set. Identification for the factory setting derives from the order No. and the respective "Factory Setting" Order number and Setting see supplementary sheet "Factory Setting"...
1 Device versions Bezeichnung Artikel- Nr. * Messgröße Ausgang / Schnittstellen / Ausstattung 4.383x.xx.xxx Depending on Configuration concerning US-Anemometer 3D article no. - outputs - data telegrams - scaling - heating - etc. 2 Preparation for operation 2.1 Installation of anemometer Proper installation of the ultrasonic anemometer is carried out using a tube socket Ø...
2.2 Alignment to north For exact determination of the wind direction the anemometer has to be installed aligned to the north (true north). Wiev from above The position of the Y vector of the transformed natural coordinate system is vertical to the measurement path U formed by the ultrasonic transformers 1 and 4.
A North- ring is available as an optional feature to assist with alignment and for simple replacement of the ultrasonic anemometer without readjustment of north. On initial installation this north- ring is mounted loose so it still rotates on the measuring mast. The north pin of ...
Page 7
Coupling socket 507550 (Binder, Serial 423), EMC with cable clamp Cable- pull- relief View X 1. Stringing parts on cable acc. Cable mounting 1 to plan given above. Viev X 2. Stripping cable sheath 20mm Cutting uncovered shield 15mm Cable shield Stripping wire 5mm.
2.4 Connector pin assignment (functional examples) Note: - The exact functional assignment can be found in the supplementary sheet "Factory Setting". - Pins 1 to 6 (inclusive) are electrically isolated from the supply voltage and the housing. • View of solder terminal Serial interface, full duplex of coupling socket Pin Assignment...
3 Maintenance As the device does not have moving parts, i.e. is not subject to wear during operation, no servicing is required. Note During storage, installation, de-installation, transport or maintenance of the anemometer it must be ensured that no water gets into the shaft or connector of the anemometer.
Page 11
Analog inputs Number Up to five analog inputs possible (3x standard, 2x additionally configurable in consultation with manufacturer) Data processing Output of measured values in user-specific telegram Input voltage 0 ... 10.0V Sampling rate 0.1 ... 100Hz per channel Resolution 16bit 0.1 % in range –40 ...
Page 12
Supply: (with 4.383x.4x.xxx) U: 48VAC/DC ±15%, 45 … 65Hz electronic + P: typ. 360VA, max. 400VA @ 48V heating - with heating of sensor arms, centre rod, US-converter and ..housing Protection type IP 67 (in case of conventional mounting and screwed and converted coupling socket (if necessary), see chapter „Preparation for operation“) Icing-up resistance As per THIES STD 012001...
7 More Information / Documents as download Further information can be found in the short instructions for use. These document and also the instruction for use are available for download under the following links. Short instruction for use https://www.thiesclima.com/db/dnl/4.383x.xx.xxx_US-Anemometer-3D_e_short.pdf Instruction for use https://www.thiesclima.com/db/dnl/4.383x.xx.xxx_US-Anemometer-3D_e.pdf Please contact us for your system requirements.