  • Page 1 QUANTA ® Q2000-F AC RMS Voltage Q2000-G AC RMS Current Process Monitors Operator’s Manual http://www.newportUS.com/manuals...
  • Page 2 NEWPORT will add the CE mark to every appropriate device upon certification. The information contained in this document is believed to be correct but NEWPORT Electronics, Inc. accepts no liability for any errors it contains, and reserves the right to alter specifications without notice.
  • Page 3 QUANTA CROSS REFERENCE DISPLAY RESOLUTION ±1999 counts (3 1/2 digits) BQ2X ±9999 counts (4 digits) BQ9X DISPLAY TYPE & METER POWER (LCD is only available on Q2000 models) LED, 120 V ac (50/60 Hz) BQ20 or BQ90 LCD, 120 V ac (50/60 Hz) BQ21 LED, 240 V ac (50/60 Hz) BQ22 or BQ92...
  • Page 5: Table Of Contents

    TABLE OF CONTENTS CROSS REFERENCE ....................iii SAFETY CONSIDERATIONS ...................... ii _2000 MAIN ASSEMBLY Specifications ......................1 Mechanical Assembly and Installation ................ 3 Power & Signal Input Connections ................4 Configuration Procedure ................... 5 Configuration Charts ....................5 Tests and Diagnostics ....................7 Main Board Connector Pin Assignments ..............
  • Page 6: Safety Considerations

    SAFETY CONSIDERATIONS This device is marked with the international Caution symbol. It is important to read this manual before installing or commissioning this device as it contains important information relating to Safety and EMC (Electromagnetic Compatibility). Unpacking & Inspection Unpack the instrument and inspect for obvious shipping damage. Do not attempt to operate Note the unit if damage is found.
  • Page 7: 2000 Main Assembly 1.0 Specifications

    MAIN ASSEMBLY - _2000 SPECIFICATIONS 1.1 GENERAL The _2000 main assemblies are identified by an initial designator (_2) plus a power/ display option numeral, zero through nine (0-9). The following table identifies the main assembly types: Display Type 120 V ac 240 Vac 9-32 V dc 5 V ac...
  • Page 8 1.5 ENVIRONMENTAL Operating Temp (Ambient): 0 to 60°C Storage Temp.: -40 to 85°C Humidity: To 95% RH, non-condensing, 0 to 40°C 1.6 MECHANICAL Case Material: UL-rated 94 V-0, polycarbonate Weight: 0.57 kg (with interface board) CLAMP SCREW CASE, UPPER CONTROL INTERFACE SLIDE CLAMP EXCITATION VOLTAGE MODEL &...
  • Page 9: Mechanical Assembly And Installation

    MECHANICAL ASSEMBLY & INSTALLATION 2.1 PANEL MOUNTING PROCEDURE (SEE FIGURE 1) Remove the main board edge connector (J1), if installed. Remove the interface board connector (J2), if installed. Loosed two clamp screws on the rear of the case enough to rotate the two slide clamps. Slide two slide retainers toward the rear of the case and remove them.
  • Page 10: Power & Signal Input Connections

    POWER AND SIGNAL INPUT CONNECTIONS WARNING: Incorrect power input can damage your PANEL METER 3.1 POWER CONNECTIONS Terminal Connection AC Versions Wire Color AC power HI Black AC power LO (neutral) White AC power GND Green Terminal Connection DC Versions No connection DC power + DC power - (return)
  • Page 11: Configuration Procedure

    CONFIGURATION PROCEDURE This procedure is used to set the decimal point of the display and interface board signal bypass selections for the configuration of the _2XXXX Display and power options 20 through 29 (see Cross Reference). For _9XXXX options 90 through 98 see Section 13. The main assembly's configuration can be changed by using the push-on jumpers provided.
  • Page 12 5.2 INTERFACE BOARD SIGNAL BYPASS SELECTION Step 1: Check your part number for a zero (0) in the following position; _2XX0X. If there is a zero (0) in that position, interface board signal bypass is required. Step 2: Remove all push-on jumpers not used in the desired configuration(s). Step 3: Select the desired configuration from the chart below, then install the push-on jumpers indicated.
  • Page 13: Tests And Diagnostics

    TESTS & DIAGNOSTICS 6.1 TEST CONFIGURATION REQUIREMENTS The main assembly is designed to function with a signal conditioner board as a minimum configuration. There is no provision for testing a main assembly alone. 6.2 SIGNAL INPUT REQUIREMENTS Signal input requirements for your configuration are identified in the signal conditioner section of this manual.
  • Page 14: Drawings

    DIMENSIONAL DRAWINGS 1.89 [48.0] 3.78 [96.0] 0.31 [7.9] SLIDE RETAINER 5.50 [139.6] CASE CLAMP RING TERMINAL BLOCK COVER 1.77 [45.0] Notes: Dimensions are in inches ±0.01" with millimeters in [ ] ±0.25 mm. 92.0 [3.62] 45.0[1.77 ] REAR VIEW (TERMINAL BLOCK COVER AND BEZEL NOT SHOWN FOR CLARITY) SLIDE CLAMPS ROTATED AND SLIDE RETAINERS REMOVED AS SHOWN FOR INSTALLATION.
  • Page 15 Assembly Diagram LED Display Used on 20, 22, 24, 26 & 28 (see Cross Reference)
  • Page 16 Assembly Diagram LCD Display Used on 21, 23, 25, 27 & 29 (see Cross Reference)
  • Page 17: Specifications

    MAIN ASSEMBLY _9000 SPECIFICATIONS 9.1 GENERAL The _9000 main assemblies are identified by an initial designator (_9) plus a power/ display option numeral: 0, 2, 4, 6 or 8. The following table identifies the main assembly types: Display Type 120 V ac 240 V ac 9-32 V dc 5 V ac...
  • Page 18 9.2 POWER AC Models: 24/120/240V +10/-15% 47-63 Hz Common Mode Voltage: 1500Vp test (354 Vp per IEC spacing), DC Models: 5V ±5% (5V return common to signal LO) 9 to 32V (300V isolation from 9-32V return to signal LO), (100Vp per CE) Source Impedance: 3 ohms Ripple:...
  • Page 19 CLAMP SCREW CASE, UPPER CONTROL INTERFACE SLIDE CLAMP EXCITATION VOLTAGE MODEL & POWER SERIAL NO. CONTROL INTERFACE BOARD OPTION SLIDE CASE INTERCONNECT RETAINER CABLE SIGNAL CONDITIONER BOARD TERMINAL BLOCK COVER LENS ZERO ADJ. ANALOG OUTPUT BOARD INPUT POWER MAIN BOARD SPAN ADJ.
  • Page 20: Mechanical Assembly And Installation

    10.0 MECHANICAL ASSEMBLY & INSTALLATION 10.1 PANEL MOUNTING PROCEDURE (SEE FIGURE 3) Remove the main board edge connector (J1), if installed. Remove the interface board connector (J2), if installed. Loosed two clamp screws on the rear of the case enough to rotate the two slide clamps. Slide two slide retainers toward the rear of the case and remove them.
  • Page 21: Power & Signal Input Connections

    11.0 POWER AND SIGNAL INPUT CONNECTIONS WARNING: Incorrect power input can damage your PANEL METER 11.1 POWER CONNECTIONS Terminal Wire Color Wire Color Connection AC Versions Other AC power HI Black Brown AC power LO (neutral) White Blue AC power GND Green Green Terminal Connection...
  • Page 22: Configuration Procedure

    12.0 CONFIGURATION PROCEDURE This procedure is used to set the decimal point of the display and interface board signal bypass selections for the configuration of the _9XXXX display and power options 90 through 98 (see Cross Reference). The main assembly's configuration can be configured using the push-on jumpers provided or already positioned on the pin-forests.
  • Page 23 13.2 INTERFACE BOARD SIGNAL BYPASS SELECTION Step 1: Check your part number for a zero (0) in the following position; _9XX0X. If there is a zero (0) in that position, interface board signal bypass is required. Step 2: Remove all push-on jumpers not used in the desired configuration(s). Step 3: Select the desired configuration from the chart below, then install the push-on jumpers indicated.
  • Page 24 13.3 REFERENCE VOLTAGE (RV1, RV2) Step 1: Remove all push-on jumpers not used in the desired configuration(s). Step 2: Select the desired configuration from the chart below, then install the push-on jumpers indicated. Reference Voltage Configuration 1 Volt 2 Volts...
  • Page 25: Tests And Diagnostics

    14.0 TESTS & DIAGNOSTICS 14.1 TEST CONFIGURATION REQUIREMENTS The _9000 main assembly is designed to function with a signal conditioner board as a minimum configuration. There is no provision for testing a main assembly alone. 14.2 SIGNAL INPUT REQUIREMENTS Signal input requirements for your configuration are identified in the signal conditioner section of this manual.
  • Page 26: Main Board Connector Pin Assignments

    15.0 MAIN BOARD CONNECTOR PINOUTS (J1) (Left to right, looking at rear of case) Connection Function A - 1 Spare Oscillator 100 kHz -8.2 V dc Analog power C - 3 Spare + Pol (sign) + Polarity sign HOLD Led version only E - 5 Spare Buffer...
  • Page 27: Rear View

    16.0 DRAWINGS 16.1 DIMENSIONS 1.89 [48.0] 3.78 [96.0] 0.31 [7.9] SLIDE RETAINER 5.50 [139.6] CASE CLAMP RING TERMINAL BLOCK COVER 1.77 [45.0] Notes: Dimensions are in inches ±0.01" with millimeters in [ ] ±0.25 mm. PANEL THICKNESS 92.0 [3.62] 6,4 (.25) MAX 0,8 (.03) MIN 45.0[1.77 ] R(.06)
  • Page 28 16.2 4 DIGIT LED MAIN ASSEMBLY...
  • Page 29 NOTES...
  • Page 30: Signal Conditioner Input 17.0 Specifications

    17.0 17.0 SPECIFICATIONS: BSCF TRUE-RMS VOLTAGE - BSCF/G TRUE RMS CURRENT (_2000F, _2000G) AC RMS VOLTAGE, AC RMS CURRENT 17.1 GENERAL The basic signal conditioner board is identified as a BSCF (_2000F or _9000F) for true-RMS voltage input. The _2000 and _9000 prefix is determined by the main assembly board used with the BSCF option board.
  • Page 31: Input Impedance

    _9000F TRUE-RMS VOLTAGE INPUTS RANGE INPUT RESOLUTION FREQUENCY RANGE IMPEDANCE 99.99 mV 1.1 MOhm 10 µV 47 Hz to 1 kHz 999.9 mV 1.1 MOhm 100 µV 47 Hz to 1 kHz 9.999 V 1 MOhm 1 mV 47 Hz to 1 kHz 99.99 V 1 MOhm 10 mV...
  • Page 32: Count Range

    _2000G TRUE RMS Current Inputs Input Impedance (200 Frequency Range Resolution mV Shunt) Range 19.99 uA 10 kOhm 0.01 uA 199.9 uA 1 kOhm 0.1 uA 1.999 mA 100 Ohm 1 uA 19.99 mA 10 Ohm 10 uA 47 Hz-1 kHz 199.9 mA 1 Ohm 100 uA...
  • Page 33 Q9000G TRUE RMS CURRENT INPUTS Input Impedance (100 Frequency Range Resolution mV Shunt) Range 9.999 uA 10 kOhm 1 nA 99.99 uA 1 kOhm 10 nA 999.9 uA 100 Ohm 100 nA 9.999 mA 10 Ohm 1 uA 47 Hz-1 kHz 99.99 mA 1 Ohm 10 uA...
  • Page 34: Signal Input Connections

    Common Mode Analog ground to ac power ground CMR @ dc to 60 Hz 120 dB CMR @ dc to 60 Hz ±1500 Vp per HV test ±354 Vp per IEC spacing Accuracy @ 25°C Maximum Error (1 to 100% of FS) _2000G ±0.25% R ±1 count _9000G...
  • Page 35 18.0 SIGNAL INPUT CONNECTIONS (TB1) (SEE FIGURE 5) 18.1 The signal input connections for the BSCF (_2000F) AC RMS Voltage Signal Conditioner are made at the standard 3-terminal barrier strip: Terminal Connection Signal Input Signal HI (dc coupled) Signal LO Signal HI (ac coupled) Coupled Terminal...
  • Page 36: Test And Diagnostics

    19.0 TESTS & DIAGNOSTICS The signal conditioner board BSCF is designed to function with a main assembly as a minimum configuration. There is no provision for testing a signal conditioner board alone. Signal input requirements for your configuration are identified in the specifications for the BSCF signal conditioner.
  • Page 37 Current Range Selection RMS Input Range GCR1/G1 Current Range (0/20 uA RMS Input) GCR2/G2 Current Range (0/200 uA RMS Input) GCR3/G3 Current Range (0/2 mA RMS Input) GCR4/G4 Current Range (0/20 mA RMS Input) GCR5/G5 Current Range (0/200 mA RMS Input) GCR6/G6 Current Range (0/2 A RMS Input) GCR7/G7...
  • Page 38: Installation

    Based on the current range selected pick a shunt resistor (R1) from the following: GCR1/G1 = 10 kOhm, 1%, 1/8W, MF (P/N 8211002) GCR2/G2 = 1 kOhm, 1%, 1/8W, MF (P/N 8211001) GCR3/G3 = 100 Ohm, 1%, 1/8W, MF (P/N 8211009) GCR4/G4 = 10 Ohm, 1%, 1/8W, MF (P/N 8211008) GCR5/G5 = 1.0 Ohm, 1%, 1/8W, WW (P/N 8710006) GCR6/G6 = 0.1 Ohm, 1%, 1/2W, WW (P/N 8910005)
  • Page 39: Configuration Charts

    21.0 CONFIGURATION CHARTS 21.1 INPUT VOLTAGE (F1, 2, 3, 4, 5, 6) (FVR1, 2, 3, 4, 5, 6) Step 1: Remove all push-on jumpers not used in the desired configuration(s). Step 2: Select the desired configuration from the chart below, and install the push-on jumpers indicated.
  • Page 40 21.2 INPUT CURRENT(G1, 2, 3, 4, 5, 6, 7) (GCR1, 2, 3, 4, 5, 6, 7) Step 1: Remove all push-on jumpers not used in the desired configuration(s). Step 2: Select the desired configuration from the chart below, and install the push-on jumpers indicated. Input Current Configuration Used On GCR1/G1...
  • Page 41: Calibration

    22.0 CALIBRATION _2000 F/G Define the input for full scale (Span pot) and zero (Zero pot) and apply to the calibration procedures at the bottom of the page. 22.1 VOLTAGE RANGES (FVR1-6/F1-6) For FVR1-5/F1-5: Full Scale = 2000 counts 1% FS = 20 counts NOTE: Full Scale for FVR6/F6 is 650 V.
  • Page 42: Drawings

    24.0 BSCF ASSEMBLY DIAGRAM Assembly Diagram Used on Signal Conditioner Board BSCF (_2000F & _2000G)
  • Page 43: Unpacking And Inspection

    25.0 DIGITAL PANEL METER INSTALLATION INSTRUCTIONS IMPORTANT: For proper installation, electrical connections must be made according to the model number on the meter label. Write the model number in the following space and use the appropriate instructions for your model number. Power requirement (Section 25.3) Analog output (see Analog Output Manual) Control output (see Controller/ Interface Manual)
  • Page 44: Mechanical Installation

    25.2 MECHANICAL INSTALLATION Insure that the panel cutout dimensions are as shown on Figure 6. Remove the lower printed circuit board edge connector, (if installed) J1, by pushing two molded plastic tabs away from the connector body and pulling the connector off the printed circuit board. Remove the printed circuit board edge connector, J2, if upper board output option was ordered.
  • Page 45 25.3 POWER REQUIREMENTS & CONNECTIONS (TB1) 25.3.1 The standard meter is wired to operate from one of five power sources Models Power Requirements _20XXX, _21XXX, _90XXX 120 V ac (50-60 Hz) _22XXX, _23XXX, _92XXX 240 V ac (50-60 Hz) _24XXX, _25XXX, _94XXX 9-32 V dc _26XXX, _27XXX, _96XXX 5 V dc...
  • Page 46: Signal Input Connections (Tb1)

    26.0 SIGNAL INPUT CONNECTIONS (TB1) 26.1 The signal input connections for the BSCF (_2XXXF) AC RMS Voltage Signal Conditioner are made at the standard 3-terminal barrier strip: Terminal Connection Signal Input Signal HI (dc coupled) Signal LO Signal HI (ac coupled) Coupled Terminal Connection...
  • Page 47 Warranty/Disclaimer NEWPORT ELECTRONICS, INC. warrants this unit to be free of defects in materials and workmanship for a period of one (1) year from date of purchase. In addition to NEWPORT’s standard warranty period, NEWPORT ELECTRONICS will extend the warranty period for one (1) additional year if the warranty card enclosed with each instrument is returned to NEWPORT.
  • Page 48 Postbus 8034 • 1180 LA Amstelveen • The Netherlands TEL: +31 20 3472121 • FAX: +31 20 6434643 Toll Free: 0800 0993344 • www.newport.nl • e-mail: info@newport.nl Newport Electronics spol s.r.o. Frystatska 184, 733 01 Karviná • Czech Republic TEL: +420 59 6311899 • FAX: +420 59 6311114 Toll Free: 0800-1-66342 •...