  • Page 1 LYNK II SAJ H2 Series Manual Revision REV A...
  • Page 2: Table Of Contents

    LYNK II CAN Out - RJ45 PIN Assignments for SAJ Inverters......13 INSTALLING AND CONNECTING LYNK II TO THE SAJ NETWORK .......15 Networking Discover Lithium Batteries with LYNK II.......... 15 Connecting LYNK II to the SAJ Network ............. 17 ENABLING LYNK II TO COMMUNICATE WITH SAJ DEVICES ........19 SAJ Closed-Loop Configuration................
  • Page 3 LYNK II SAJ H2 Series Manual Document: 805-0102 Revision: A – 3...
  • Page 4: Introduction

    LYNK II SAJ H2 Series Manual 1 INTRODUCTION This document provides information about integrating LYNK network-enabled Discover Lithium Batteries using the LYNK II Communication Gateway with SAJ power conversion devices in a closed- loop configuration. Before installation and configuration, consult the relevant product documentation, including Manuals, Application Notes, and Installation and Configuration Guides.
  • Page 5 The LYNK II Communication Gateway is compatible with the following batteries and inverters. Discover Lithium Batteries A Discover battery must have a compatible network port, such as a LYNK Port or AEbus Port, to communicate with a LYNK II device.
  • Page 6: Audience, Safety, Messages, And Warnings

    LYNK II SAJ H2 Series Manual 2 AUDIENCE, SAFETY, MESSAGES, AND WARNINGS 2.1 Audience Configuration, installations, service, and operating tasks should only be performed by qualified personnel in consultation with local authorities having jurisdiction and authorized dealers. Qualified personnel should have training, knowledge, and experience in the: •...
  • Page 7: General Warnings

    LYNK II SAJ H2 Series Manual NOTICE Important information regarding conditions that may result in damage to the equipment but not personal injury. NOTE Ad hoc information concerning important procedures and features of the battery not related to personal injury or equipment damage.
  • Page 8: Electric Shock

    LYNK II SAJ H2 Series Manual ELECTRIC SHOCK • Do not touch the energized surfaces of any electrical component in the battery system. • Before servicing the battery, follow all procedures to fully de-energize the battery system. • Follow the “Safe Handling Procedures” below when working with the battery.
  • Page 9 LYNK II SAJ H2 Series Manual • Avoid dropping the device or battery. If the device or battery is dropped, especially on a hard surface, and the user suspects damage, take it to a service center for inspection. AUDIENCE, SAFETY, MESSAGES, AND WARNINGS– 9...
  • Page 10: Overview

    Configure the LYNK II CAN out pins to match the CAN in pins of the power conversion equipment. • Mount the LYNK II, connect the Discover battery communication network to the LYNK Port and then connect the LYNK II’s CAN Out Port to the power conversion equipment's communication network.
  • Page 11: Minimum Battery System Capacity

    LYNK II SAJ H2 Series Manual 3.2 Minimum Battery System Capacity The Discover Lithium Battery and SAJ device automatically manage the battery charge and discharge rates. Using large solar arrays with battery banks that are too small can exceed the operating limits of the battery to charge and possibly lead to the BMS triggering over-current protection.
  • Page 12 RMS, 95 A DC Continuous Charge/Discharge (1 hour), as published in Discover AES RACKMOUNT Installation and Operation Manual (805-0043 Rev J). Discover HELIOS ESS 52-48-16000 Battery, Peak Discharge Current (15 seconds): 300 A RMS, 200 A Continuous Charge/Discharge, as published in Discover HELIOS ESS Installation and Operation Manual (805-0090 Rev D).
  • Page 13: Lynk Ii Can Hardware Termination And Can Out Pin Configuration . 1

    LYNK II terminates the AEbus and LYNK Network by default. Do not remove the termination jumper inside LYNK II unless instructed to do so by Discover Energy Systems. 4.2 LYNK II CAN Out - RJ45 PIN Assignments for SAJ Inverters CAN signals (CAN H, CAN L, CAN GND) can be assigned to any pin of the RJ45 connector by adjusting the jumpers on the header board.
  • Page 14 LYNK II SAJ H2 Series Manual CAN Out Header Jumper RJ45 Pin CAN L H2 - 5- 7 CAN H H3 - 8 -10 CAN GND LYNK II CAN HARDWARE TERMINATION AND CAN OUT PIN CONFIGURATION– 14...
  • Page 15: Installing And Connecting Lynk Ii To The Saj Network

    LYNK II requires power from three possible sources (13-90 VDC power supply, LYNK Port enabled Discover Lithium battery, or a USB device). • Discover Lithium batteries must be set to ON to supply power and communicate data with LYNK II. AES RACKMOUNT  INSTALLING AND CONNECTING LYNK II TO THE SAJ NETWORK– 15...
  • Page 16 LYNK II SAJ H2 Series Manual Both LYNK II and AES RACKMOUNT Battery Modules are internally terminated. No extra termination is required. HELIOS ESS Both LYNK II and HELIOS ESS batteries are internally terminated. No extra termination is required. INSTALLING AND CONNECTING LYNK II TO THE SAJ NETWORK– 16...
  • Page 17: Connecting Lynk Ii To The Saj Network

    LYNK II SAJ H2 Series Manual NOTICE TERMINATION REQUIREMENT HELIOS ESS Batteries prior to serial number DLPHD48B251080001 are supplied with a termination resistor. When setting up closed-loop communication with these HELIOS ESS Batteries, plug the termination resistor into the COM3/COM4 port on the last battery in the LYNK network.
  • Page 18 LYNK II SAJ H2 Series Manual INSTALLING AND CONNECTING LYNK II TO THE SAJ NETWORK– 18...
  • Page 19: Enabling Lynk Ii To Communicate With Saj Devices

    LYNK ACCESS software for 64-bit Windows 10 / 11 is required to configure LYNK II settings for closed-loop CAN communication with SAJ inverters. When the SAJ inverter is configured in a closed loop with Discover Lithium batteries and the communication breaks between the LYNK II and the inverter, after a few seconds, the inverter safely stops operation and displays an alarm.
  • Page 20: Setting Closed-Loop Configuration On The Saj Inverter

    LYNK II and that the LYNK II is connected to the SAJ inverter's CAN port. Refer to the latest Discover Energy Systems documentation for battery values and the latest SAJ documentation for menu navigation and details on the setup procedure.
  • Page 21 LYNK II SAJ H2 Series Manual Log in to the Elekeeper app and register your Solar and energy storage system. From the Service page, select Remote Configuration. Pair the inverter with your phone: On the app, set the Connection Method to Bluetooth and click Next.
  • Page 22 LYNK II SAJ H2 Series Manual Configure the System Parameters Follow the on-screen instruction to complete initialization. If connecting multiple inverters in parallel, set the parallel connection settings. ENABLING LYNK II TO COMMUNICATE WITH SAJ DEVICES– 22...
  • Page 23 LYNK II SAJ H2 Series Manual Configure the battery settings. In the Battery Brand page, select Discover LYNK. In the Battery Settings page, set the battery parameters based on the electrical specifications for the battery as specified in its battery manual.
  • Page 24 LYNK II SAJ H2 Series Manual NOTE Depending on your system and particular use case, there may be other settings that require configuration. Refer to the inverter manual for information on these settings. ENABLING LYNK II TO COMMUNICATE WITH SAJ DEVICES– 24...
  • Page 25: Appendix

    LYNK II SAJ H2 Series Manual 7 APPENDIX 7.1 SAJ Open-Loop Configuration Refer to the latest Discover Battery documentation for battery values and the latest SAJ documentation for details on menu navigation and the setup procedure. NOTE Depending on your system and particular use case, there may be other settings that require configuration.
  • Page 26 5. Set the Battery Brand to Lead Acid and set the Battery Parameters based on the electrical specifications for the battery as specified in its battery manual. FIRE AND BURN HAZARD Do not perform an equalization charge on a Discover lithium battery. Failure to follow these instructions may result in injury. APPENDIX– 26...

Table of Contents