(950-0025)
USER MANUAL - SCHNEIDER
XW PRO WITH SCHNEIDER BMS
READ AND SAVE THESE INSTRUCTIONS
805-0061 REV B
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LYNK II and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for DISCOVER LYNK II

  • Page 1 (950-0025) USER MANUAL - SCHNEIDER XW PRO WITH SCHNEIDER BMS READ AND SAVE THESE INSTRUCTIONS 805-0061 REV B...
  • Page 2: Table Of Contents

    Setting the LYNK II Communication Protocol ........
  • Page 3: Introduction

    Introduction This Application Note provides information about integrating LYNK and AEbus network-enabled Discover Lithium Batteries using the LYNK II Communication Gateway with Schneider Electric BMS-enabled inverter-chargers, solar charge controllers, and other devices. 1 . AUDIENCE, WARNINGS, MESSAGES, GENERAL SAFETY, PERSONAL PROTECTIVE EQUIPMENT 1 .1 Audience...
  • Page 4: General Warnings

    1 .3 General Warnings WARNING ELECTRIC SHOCK AND FIRE HAZARD • A lithium battery must be installed as specified. • Do not disassemble or modify the battery. • If the battery case has been damaged, do not touch exposed contents. •...
  • Page 5: Personal Protective Equipment

    Schneider Electric Documentation Visit solar.se.com for the most recent version of published documents. Discover Energy Systems Documentation Visit discoverlithium.com for the most recent version of published documents, including Discover Lithium battery user manuals and the LYNK II Installation and Operation Manual (805-0033).
  • Page 6: Overview

    • Connect the LYNK II Phoenix connector CAN pins to the InsightHome/ InsightFacility CAN pins. • Ensure all networks are correctly terminated. • Set the LYNK II Gateway to the correct protocol using LYNK ACCESS software to enable closed-loop communication between the Discover batteries and the power conversion equipment.
  • Page 7: Compatible Batteries And Devices

    • MPPT 100-600 • InsightHome / InsightFacility Discover Lithium Batteries A Discover battery must have a compatible network port, such as a LYNK Port or AEbus Port, for communicating with a LYNK II device. • AES LiFePO : 42-48-3000, 42-48-6650 •...
  • Page 8: Minimum Battery System Capacity

    Discover AES RACKMOUNT User Manual (805-0043 REV D). Discover DLP-GC2-48V Battery, Peak Power: 90 A DC (3 seconds), Max Charge (1 hour): 29 A DC, Max Discharge (1 hour): 58 A DC, as published in Discover DLP-GC2-48V User Manual (2023/08).
  • Page 9: Installing And Connecting Lynk Ii To The Can Network

    • Do not plug an AEbus RJ45 network cable or terminator into the 10/100 Ethernet port of the LYNK II. • Do not connect a CAT5 cable from the AEbus, LYNK, or Ethernet ports of the LYNK II to a WAN or MODEM port of a network router.
  • Page 10 NOTE AES LiFePO 48 V batteries sold before Jan 1, 2020, will not supply power to LYNK II using the network cable connection. An external 13-90 VDC power source connected to the Phoenix 12-pin connector on LYNK II is REQUIRED for the AES LiFePO batteries listed below.
  • Page 11: Connecting Lynk Ii To The Schneider Electric Insight Device

    Schneider Electric power conversion devices. 20 AWG wires are recommended to connect the CAN pins on the 12-pin connector of the LYNK II to the CAN pins of either the 12-pin connector of InsightHome or the 26-pin connector of InsightFacility.
  • Page 12 Bottom Top Row Digital Output Digital input 9 11 (0-40 VDC) 1 (12 VDC) Digital input 2 (12 VDC) Do Not Do Not Connect Connect 8 10 12 GND ISO GND ISO RS485 A ISO CAN L ISO RS485 B ISO CAN H ISO Figure 7.
  • Page 13: Enabling Communication Between The Lynk Ii And Schneider Electric Devices

    InsightFacility with InsightLocal or InsightCloud access is required to configure the XW PRO, MPPT Charge Controllers, and other Schneider Electric devices. If communication between the LYNK II and the XW PRO is lost, it will display either a Fault or a Warning.
  • Page 14: Setting The Lynk Ii Communication Protocol

    (LYNK ACCESS 1.2.0 or later includes the Schneider BMS protocol). 2. Connect a USB cable with a mini-B plug to the USB port on the LYNK II and the Type-A plug to the 64-bit Windows 10 device running LYNK ACCESS software.
  • Page 15 b. From Firmware Upgrade, click Upload Package and install the latest firmware file. 2. Update the firmware of the XW PRO. a. Devices > Inverter/Chargers > Firmware b. Click Upgrade and install the latest firmware file. 3. Update the firmware of the MPPT controller. a.
  • Page 16: Verification Of Battery Network Connections

    Set to 1.0 V 5 .3 Verification of Battery Network Connections Review the following steps to verify that all batteries communicate with the LYNK II Gateway and the Schneider system. • Devices > Inverter/Chargers > Configuration (Advanced) > Battery Settings...
  • Page 17: Xw Pro Configuration Settings - Insightlocal

    If closed-loop communications fail, preset open-loop (Comms Lost) values for XW PRO open-loop operation are selected by the Battery Type during the BMS Setup. LYNK II does not configure these settings; the values provided are only for reference. Many factors can influence DC voltage. State-of-Charge (SOC) is considered more reliable than DC voltage as a trigger value.
  • Page 18: Xw Pro - Battery Management System Settings

    SOC Communication. (Seconds) Comms Lost Battery When a Discover battery is selected in BMS Setup, XW PRO Charge Voltage Limit defaults to 54.4 V when Comms Lost (Open-loop). This value is used if BMS or battery SOC communication is lost.
  • Page 19 System Values > Battery Management System Settings Comms Lost Battery When a Discover battery is selected in BMS Setup, XW PRO Discharge Voltage defaults to 48.0 V when Comms Lost (Open-loop). This value Limit (V) is used if BMS or battery SOC communication is lost.
  • Page 20 > Battery Management System Settings Discharge Overcurrent When a Discover battery is selected in BMS Setup, XW PRO Trip Time (Seconds) defaults to a 2 s delay before an F71 fault is triggered when the Discharge Overcurrent trip threshold is exceeded (refer to Discharge Overcurrent Offset).
  • Page 21: Xw Pro - Battery Settings

    Figure 13. Battery Settings InsightLocal > Battery System Values Settings Battery Type (Flooded, When a Discover battery is selected in BMS Setup, this GEL, AGM, Custom, defaults to Li-ion. Li-ion) Charge Cycle (3 Stage, When a Discover battery is selected in BMS Setup, this 2 Stage, External BMS) defaults to External BMS.
  • Page 22 When operating in a closed loop, this value is dynamically Point (V) managed to charge and balance efficiently without causing an over-voltage fault. When a Discover battery is selected in BMS Setup, XW PRO defaults to 54.4 V in Comms Lost (Open-loop).
  • Page 23 Point (V) managed to charge and balance efficiently without causing an over-voltage fault. When a Discover battery is selected in BMS Setup, XW PRO defaults to 54.4 V in Comms Lost (Open-loop). Maximum Discharge When a Discover battery is selected in BMS Setup, XW PRO...
  • Page 24: Xw Pro - Charger Settings

    InsightLocal > Battery System Values Settings High SOC Cut-Out When a Discover battery is selected in BMS Setup, XW PRO Delay (Seconds) defaults to 60 s when operating in a closed loop. Setting SOC Cut Out delay avoids unnecessary engagement of the Battery Management System (BMS) safety features.
  • Page 25: Mppt Solar Charge Controller Configuration Settings - Insightlocal

    Schneider BMS protocol. Most values are automatically communicated by the Discover batteries when closed-loop connected through the Schneider BMS protocol. LYNK II does not configure these settings. Some values are dynamic and will constantly change when in a closed-loop operation and cannot be overridden by the user.
  • Page 26: Mppt Solar Charge Controller - Charger Settings

    Figure 15. Charger Settings CAUTION FIRE AND BURN HAZARD Do not perform an equalization charge on a Discover Lithium battery. Failure to follow these instructions may result in minor to moderate injury. NOTICE If closed-loop communications fail, the MPPT Solar Charge Controllers will continue to operate in the Last State before communication is lost.
  • Page 27 InsightLocal > Charger System Values Settings Absorption Voltage Set Point Ignore the displayed value. When operating in a closed loop, this value is dynamically managed to charge and balance efficiently without causing an over-voltage fault. Absorption Time (Minutes) When operating in a closed loop, this value is dynamically managed to charge and balance efficiently without causing an over-voltage fault.
  • Page 28: Mppt Solar Charge Controller - Battery Settings

    Battery Bank Capacity This value must be set to the number of batteries in the (Ah) system multiplied by the rated capacity of the Discover Lithium battery. The battery model determines the capacity value: 130 A for a single 42-48-6650, 57 A for a single 44-48-3000, 30 A for a single DLP-GC2-48V, and 100 A for a single 48-48-5120.

This manual is also suitable for:

950-0025

Table of Contents