Page 1
Installation and operating instructions ELECTRIC SOLID TOP-PLATE FOR PROFESSIONAL USE TPK-98ETT Model LIBR.ISTR.S90D TPK-ETT Code 5630612A0 Review 1 Edition date 20/11/2024 Language English LOTUS S.p.A. Via Calmaor, 46 31020 San Vendemiano +39 0438 778020 +39 0438 778277 Translation of the original instructions...
Contents Contents INTRODUCTION ......................... Installation drawing ........................Example installation of the appliance................... GENERAL INFORMATION......................Declaration of compliance......................User information, RAEE Directive on waste electrical and electronic equipment ......Technical data table ........................INSTALLATION........................... Delivery checks ..........................Removing the packaging ......................Mechanical installation .........................
INTRODUCTION 1 INTRODUCTION Installation drawing FIG. 1 TPK..9ETT A Data Plate B Electrical connection D Energy saving connection Translation of the original instructions...
Page 4
INTRODUCTION FIG. A WIRING DIAGRAM TPK-98ETT 400V~3N 50/60 Hz Translation of the original instructions...
Page 5
INTRODUCTION Electrical technical data table Three-phase power supply terminal block Power switching terminal block Resistance switching terminal block Single-pole switch Optimiser connection Resistance Digital control board K-type thermocouple temperature probe Transformer Contactor Safety thermostat Translation of the original instructions...
GENERAL INFORMATION 2 GENERAL INFORMATION Declaration of compliance The manufacturer declares that the appliances comply with the requirements of the regulation GAR 2016/426 for the gas part and directive 2014/30/EU,2014/35/EU for the electrical part. Installation must be performed in compliance with current regulations, especially with regard to ventilation of the premises and the exhaust gas evacuation system.
Equipment) are those provided for by the national transpositions of European Directives 2012/19/EU Technical data table Technical data table TPK S90ETT MAXIMUM MAXIMUM POWER CABLE MODEL DIMENSIONS POWER SUPPLY ABSORPTION POWER (kW) silicon type TPK-98ETT 80x90x90h 400V~3N 50/60 Hz 19,71 13,6 5 x 2,5 mm² Translation of the original instructions...
Page 9
GENERAL INFORMATION Table of parameters TPK-9..ETT PARAMETER Adjustment ID code DESCRIPTION U.M. Resol. field MAX temp. Maximum temperature 50 - 400 °C NTC temperature for cooling Fan temp. setting 0-50 °C fan(s) start-up Enabling of instrument compartment cooling fan(s) start-up: Cooling fan 0=always off 1=always on...
Page 10
GENERAL INFORMATION PARAMETER Adjustment ID code DESCRIPTION U.M. Resol. field Calculation limit of the PID KI constant. % referring to the PID TR (15) and defines the MaxOut PID_I maximum value of the ON time 20 - 80 component, calculated from the Integrative component alone.
INSTALLATION 3 INSTALLATION Delivery checks On delivery, it is important to check the following: · External conditions of the packaging · The general status of the equipment · The conformity of the model with the information in the technical data plate and the instruction manual ·...
INSTALLATION Warning Installation operations, any conversion to other types of gas and start-up must only be performed by qualified personnel, in accordance with current regulations. Gas systems, electrical connections and premises where the appliances are installed must comply with current regulations in the country of installation;...
Page 13
INSTALLATION Caution ALL PARTS THAT GIVE ACCESS TO LIVE PARTS AFTER REMOVAL ARE MARKED WITH THE "WARNING: DANGEROUS VOLTAGE" SYMBOL Translation of the original instructions...
INSTRUCTIONS FOR USE 4 INSTRUCTIONS FOR USE General information This appliance must only be used for its expressly intended purpose for cooking or heating food. Any other use is considered improper. The appliance is also intended for industrial use and must only be used by personnel trained for use and aware of the risks that the hot element entails.
INSTRUCTIONS FOR USE QR CODE USER MANUAL For the user instructions, refer to the 5630613A0ENNN DIGITAL LINE USER MANUAL by scanning the QR CODE below: https://www.lotuscookers.it/documenti_new/libretti/5630613A0ENNN.pdf Emptying the container This rack should be checked regularly and emptied before it is full. In any case, the rack must be cleaned after switching off the appliance ...
MAINTENANCE 5 MAINTENANCE Routine When using the appliance over time, it is essential to perform regular maintenance to ensure safe operation. We therefore recommend stipulating a service contract. Caution Maintenance must only be performed by specialist personnel in compliance with current regulations and our own instructions.
MAINTENANCE Spare parts It is possible to replace parts such as the valve, the piezoelectric or the ignition control unit (depending on the type of appliance) or the gas pipes easily and quickly. To replace such parts, proceed as follows: ...
CLEANING 6 CLEANING Routine cleaning Caution The use of flammable fluids to clean the appliance is forbidden To ensure hygiene and the durability of the appliance, perform external cleaning on a regular basis, taking care not to damage the cables and the electrical connections. Before starting cleaning, disconnect the appliance from the power supply.