OPERATION MANUAL SUBMERSIBLE DEWATERING PUMP Thank you for selecting our SP-21/26 Series Submersible Pump for your pumping requirement. Please take a moment to review this manual before, installing, operating or servicing these pumps. The pump should not be used other than the applications listed in this manual. Failure to do so may lead to a malfunction or an accident to which the manufacturer will not assume any liability.
Content Safety Instructions…………………………….…..………………………2 Before you Start.………………………………………………..…………2 III. Pump Identification ………………………………………………..……...3 IV. Installation.…………………………………………..…………………..3-4 Pump Operation...………………………………………………………4-5 VI. Maintenance...……………………………………………………………..5 VII. Specification & Parts List .……………………………………………6-10 VIII. Preventative Maintenance………………………………………………11 IX. Trouble Shooting…………………………………………………………12 Product Disposal…………………………………………………………13 SAFETY INSTRUCTION WARNING All electrical work must be performed by an authorized electrician, in compliance with local electrical codes.
Risk of Electric Shock, this pump has not been investigated for use in a swimming pool application. CAUTION When installing the pump, be mindful of the pump’s center of gravity and weight. Failure to do so, may result in the pump to fall and break which may lead to injury. ...
NEVER, allow the pump to freeze in the liquid it is pumping. Piping NOTICE All piping must be independently supported, properly aligned and capable of handling semi-solids. DO NOT, restrict the discharge flow of the pump as it will cause the pump to overheat.
WARNING Accidental starting of the pump can cause severe injury or death. It is absolutely essential that the rotation of the pump be checked. All the pumps covered in this manual turn clockwise as viewed from the motor end. ...
VII Specifications & Parts List Specifications Application Dewatering Single Motor 115V 2/3HP Phase Impeller Semi Vortex Impeller Ball bearing Shielded ball bearing Mechanical Double mechanical seal Seal Insulation Class B Parts Motor Thermal Overload Protector Protection...
VIII. Preventative Maintenance Daily 1. Ensure the Voltage and Amperage conform to the nameplate. Voltage must be within 10% of nameplate nominal voltage 2. Check if the water flow is normal. Monthly Maintenance is recommended when the insulation reading is lower than 10MΩ.
IX. TROUBLE SHOOTING Hazardous voltage can shock, burn, or kill. Disconnect the electrical power before attempting any service or work on pump SYMPTOM PROBABLE CAUSE SOLUTION Pump Fails to Start Check power and correct Incorrect Voltage/Amps connections. Defective Cable Replace Power Cable Remove foreign debris from Clogged Impeller impeller or casing.
PRODUCT DISPOSAL Properly dispose the product in accordance with your local waste disposal program. Please record the following information for future reference: Model Number: Serial Number: Purchase Date:...
Need help?
Do you have a question about the Patron SP-21 and is the answer not in the manual?