6.Command Specification

6.7.2. Control Mode Page (0Ah)

Bit
7
Byte
0
PS (0)
1
2
3
4
5
6
7
8
9
10
11
The AUTOLOAD MODE field specifies the action to be taken by the drive when a media is inserted.
Value
Definition
000b
Medium shall be loaded for full access
001b
Medium shall be loaded for medium auxiliary memory access only
010b
Medium shall not be loaded (not support)
011b-111b
Reserved
6-42
6
5
Reserved
Reserved
AUTOLOAD MODE field
4
3
Page Code (0Ah)
Page Length (0Ah)
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
SONY AIT-3Ex drive SDX-800V series Ver.1.0