Vulcan-Hart VSX3E Service Manual page 10

Vulcan vsx3e steamers: supplementary guide
Table of Contents

Advertisement

VSX SERIES STEAMER - REMOVAL AND REPLACEMENT OF PARTS
3. Loosen the compression nuts on the flexible gas
line then remove line from the gas solenoid
valve and manifold.
(VSX5G SHOWN)
4. If removing gas valve from a single unit,
proceed to step 5. If removing gas solenoid
valve from a double unit, proceed to step 6.
5. Turn "off" the water supply to the "tank fill" and
"cold water condenser" solenoids and
disconnect the fittings (bulkhead union) on the
opposite end of the incoming water
connections.
A. To access the compression fittings for the
incoming water connection, remove the
small access panel to the lower
compartment.
B. Loosen the compression nuts on the
"condenser feed" and "tank feed" water lines
and place the lines to the side.
NOTE: If necessary, loosen the remaining
compression nut on the "cold water condenser"
solenoid and rotate it out of the way.
6. Open the lower cabinet base door to gain
access the gas solenoid valves.
7. Remove the gas solenoid valve from the pipe
nipple below it.
8. Reverse procedure to install and check unit for
proper operation.
Page 10 of 40