Honeywell 5800PIR-RES Installation Instructions Manual page 5

Wireless outdoor motion sensor
Table of Contents

Advertisement

6
Perform a Walk Test
NOTE: With the Walk Test switch set to ON the LED will light when the detector is tripped, and the alarm is generated instantly.
1.
4.
Set the walk test
switch (DIP switch
1) to ON. Replace
the cover.
2.
5.
Perform a walk test
through the detec-
tion area, and verify
satisfactory results.
3.
6.
Allow the detection
area to remain
static, and check for
false or unwanted
detections.
WALK TEST
7
Program the Control Panel
Prior to use in the system, you must program the transmitter's serial number, input type (RF Supervised), response type, and loop # (set to 1)
in the control panel. Refer to the control panel's instructions for further details.
Note: If you are learning the control panel by walking, either use the Walk Test setting or temporally set the Battery Saving Timer to 5 sec.
When the programming is complete ensure the Walk Test switch is set to OFF, and the Battery Saving Timer is set to your desired setting.
Notes:
If necessary, adjust
the detection area (see
Perform Settings &
Adjustments).
Repeat the walk test
through the detection
area, and verify
satisfactory results.
Set the walk test DIP
switch 1 to OFF, and
secure the Cover with
the M3 x 10 Captive
Lock Screw.
If normal car or people traffic
pass close to the detection
area, adjust the detection
area 1.5 to 2.0m (5 to 7ft)
shorter to reduce false
detections. This also allows
for changes due to environ-
mental thermal conditions.
If the detection length is
adjusted to position "A" [12m
(40ft)], the detection area
may increase when there is a
big temperature difference
between the moving object
and the background.
This sensor has a multi-level
detection pattern (from side
view). A heat source beyond
the detection area may cause
the detector to issue a false
alarm by reflecting off the
ground. Examples include
puddles, wet surfaces, very
smooth asphalt or concrete
surfaces.
If this causes a problem,
adjust the detection length to
position "B". Then perform a
walk test to verify
satisfactory results.
– 5 –
If this causes a problem, adjust the detection
length to position "B". Then walk test to verify
satisfactory results.
Approx.8m (27ft)
position B
Approx.12m (40ft)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

5800pir-od

Table of Contents