Wlc (wireless lan controller), wism (wireless services module) integrated wlc with aps (40 pages)
Summary of Contents for Cisco Nexus 9364C-H1
Page 1
Cisco Nexus 9364C-H1 ACI-Mode Switch Hardware Installation Guide First Published: 2024-03-15 Last Modified: 2025-04-04 Americas Headquarters Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134-1706 http://www.cisco.com Tel: 408 526-4000 800 553-NETS (6387) Fax: 408 527-0883...
Page 2
Any products and features described herein as in development or available at a future date remain in varying stages of development and will be offered on a when-and if-available basis. Any such product or feature roadmaps are subject to change at the sole discretion of Cisco and Cisco will have no liability for delay in the delivery or failure to deliver any products or feature roadmap items that may be set forth in this document.
Shock and Vibration Requirements Grounding Requirements Planning for Power Requirements Rack and Cabinet Requirements Clearance Requirements Cautions and Regulatory Compliance Statements for NEBS C H A P T E R 3 Installing the Chassis Cisco Nexus 9364C-H1 ACI-Mode Switch Hardware Installation Guide...
Page 4
Installing and Removing Small-Form Pluggable Modules Install and Remove OSFP/QSFP Transceiver Modules Attaching the Optical Network Cable Removing the Transceiver Module A P P E N D I X A Rack Specifications Overview of Racks Cisco Nexus 9364C-H1 ACI-Mode Switch Hardware Installation Guide...
Page 5
A P P E N D I X D Additional Kits Rack Mount Kit NXK-ACC-RMK2-2RU A P P E N D I X E Site Preparation and Maintenance Records Site Preparation Checklist Contact and Site Information Chassis and Module Information Cisco Nexus 9364C-H1 ACI-Mode Switch Hardware Installation Guide...
Braces and a vertical bar within square brackets indicate a required choice within an optional element. Indicates a variable for which you supply values, in context where italics variable cannot be used. Cisco Nexus 9364C-H1 ACI-Mode Switch Hardware Installation Guide...
What's New in Cisco Product Documentation, at: https://www.cisco.com/warp/public/687/Directory/DirTAC.html. Subscribe to What's New in Cisco Product Documentation, which lists all new and revised Cisco technical documentation as an RSS feed and delivers content directly to your desktop using a reader application. The RSS feeds are a free service.
• Overview, on page 1 Overview The Cisco Nexus 9364C-H1 switch (N9K-C9364C-H1) is a 2-rack unit (RU), fixed-port switch designed for spine-leaf-APIC deployment in data centers. The software on this switch has 6.4T traffic-processing capability. The switch has these ports: •...
Page 12
• Spine discovery via leaf – Connect a discovered leaf to one of the default fabric links (49-64) then convert the switch to spine (reboot is required). • Sub leaf discovery via leaf – Connect a discovered leaf to one of the default fabric links (49-64). Cisco Nexus 9364C-H1 ACI-Mode Switch Hardware Installation Guide...
Page 13
15 minutes. • All the fan modules and power supplies must use the same airflow direction. The figure shows the switch features on the port side of the chassis. Cisco Nexus 9364C-H1 ACI-Mode Switch Hardware Installation Guide...
Page 14
Overview Overview Table 2: Screw holes for front mounting Grounding pad brackets (both left and right sides) Cisco Nexus 9364C-H1 ACI-Mode Switch Hardware Installation Guide...
Page 15
To determine which transceivers, adapters, and cables support this switch, see the Cisco Transceiver Modules Compatibility Information document. The figure shows the switch features on the power supply side of the chassis. Cisco Nexus 9364C-H1 ACI-Mode Switch Hardware Installation Guide...
Page 16
Overview Overview Fan modules (4) with slots Console port (1) numbered from 1 (left) to 4 (right) Cisco Nexus 9364C-H1 ACI-Mode Switch Hardware Installation Guide...
Page 17
If the switch has port-side exhaust airflow (blue coloring for fan modules), locate the ports in the hot aisle. If you locate the air intake in a hot aisle, the switch can overheat and shut down. Cisco Nexus 9364C-H1 ACI-Mode Switch Hardware Installation Guide...
Altitude rating is 10,000 ft (3048 m). For China, it is 6,562 ft (2000 m). For every 1000 feet (300 meters) elevation, the maximum ambient temperature is reduced by one degree Celsius. Cisco Nexus 9364C-H1 ACI-Mode Switch Hardware Installation Guide...
The wiring is unlikely to emit radio interference if you use a twisted-pair cable with a good distribution of grounding conductors. Copper cables should not be longer than maximum distances for the media type. Cisco Nexus 9364C-H1 ACI-Mode Switch Hardware Installation Guide...
The switch includes two power supplies (1-to-1 redundancy with current sharing) in one of these combinations: • Two 1400-W AC power supplies • Two 2000-W DC power supplies • Two 2000-W HVDC power supplies Cisco Nexus 9364C-H1 ACI-Mode Switch Hardware Installation Guide...
• Solid-walled cabinets with a roof fan tray (bottom-to-top cooling) • Standard open four-post Telco racks Work with your cabinet vendors to determine which of their cabinets meet these requirements or see the Cisco Technical Assistance Center (TAC) for recommendations: •...
19.0 in (48.3 cm) Note Both the front and rear of the chassis must be open to both aisles for airflow. Cisco Nexus 9364C-H1 ACI-Mode Switch Hardware Installation Guide...
This equipment may be ESD sensitive. Always use an ESD ankle or wrist strap before handling equipment. Connect the equipment end of the ESD strap to an unfinished surface of the equipment chassis or to the ESD jack on the equipment if provided. Cisco Nexus 9364C-H1 ACI-Mode Switch Hardware Installation Guide...
Page 25
This equipment is suitable for installations using the CBN. Note Statement 7018 System Recover Time The equipment is designed to boot up in less than 30 minutes provided the neighboring devices are fully operational. Cisco Nexus 9364C-H1 ACI-Mode Switch Hardware Installation Guide...
Page 26
Pluggable optical modules comply with IEC 60825-1 Ed. 3 and 21 CFR 1040.10 and 1040.11 with or without exception for conformance with IEC 60825-1 Ed. 3 as described in Laser Notice No. 56, dated May 8, 2019. Cisco Nexus 9364C-H1 ACI-Mode Switch Hardware Installation Guide...
Install the switch using these rack-mount options: • Rack-mount kit (N9K-C9300-RMK) which you can order from Cisco. For four post racks. The rack or cabinet that you use must meet the requirements listed the in...
Do not discard the shipping container when you unpack the switch. Flatten the shipping cartons and store them. If you need to move or ship the system in the future, you will need this container. Cisco Nexus 9364C-H1 ACI-Mode Switch Hardware Installation Guide...
The switch is designed so that you can have coolant air flow through the switch in one of two directions: The switch is designed so that you can have coolant air flow through the switch in one of two directions: Cisco Nexus 9364C-H1 ACI-Mode Switch Hardware Installation Guide...
Before you begin • Inspect the switch shipment to ensure that you have everything ordered. • Verify that the switch rack-mount kit includes these parts: • Rack-mount brackets (2) • Rack-mount front-mount brackets (2) Cisco Nexus 9364C-H1 ACI-Mode Switch Hardware Installation Guide...
Page 31
Repeat Step 1 for the other front rack-mount bracket on the other side of the rack and be sure to position that bracket horizontally to the same level as the first bracket. Cisco Nexus 9364C-H1 ACI-Mode Switch Hardware Installation Guide...
Page 32
Insert the switch into the rack and attach it. a) Align the four holes in one side of front mount brackets to three holes on the left or right side of the chassis (see the figure). Cisco Nexus 9364C-H1 ACI-Mode Switch Hardware Installation Guide...
Page 33
Insert the switch into the rack and attach it. a) Holding the switch with both hands, position the switch onto the rack-mount brackets and carefully slide the chassis into the rack (see the figure). Cisco Nexus 9364C-H1 ACI-Mode Switch Hardware Installation Guide...
Page 34
Installing the Chassis Installing the Switch using the NXK-ACC-RMK2-2RU Rack-Mount Kit Step 6 Rotate one front mount bracket to align with the rack (see the figure). Cisco Nexus 9364C-H1 ACI-Mode Switch Hardware Installation Guide...
Page 35
Align the retainer clip to the inside of the back of the slider rail. Make sure to hook the flange to the cutout on the bracket and align the screw holes (see the figure). b) Attach the screws to secure the retainer clip (see the figure). Cisco Nexus 9364C-H1 ACI-Mode Switch Hardware Installation Guide...
If you attached a grounding wire to the chassis grounding pad, connect the other end of the wire to the facility ground. Grounding the Chassis The switch chassis is automatically grounded when you properly install the switch in a grounded rack with metal-to-metal connections between the switch and rack. Cisco Nexus 9364C-H1 ACI-Mode Switch Hardware Installation Guide...
Page 37
See the figure. Verify that the ground wire is securely attached to the grounding lug by attempting to pull the wire out of the crimped lug (tug test). Cisco Nexus 9364C-H1 ACI-Mode Switch Hardware Installation Guide...
• You have the designated power cables for the power supplies that you are connecting to the dedicated power sources. Note Depending on the outlet receptacle on your AC power distribution unit, you might need an optional jumper power cord to connect the switch to your outlet receptacle. Cisco Nexus 9364C-H1 ACI-Mode Switch Hardware Installation Guide...
Page 39
Listen for the fans; they should begin operating when the power supply is powered. Step 6 After the switch boots, verify that these LEDs are lit: • On the fan modules, the Status (STA or STS) LED is green. Cisco Nexus 9364C-H1 ACI-Mode Switch Hardware Installation Guide...
Page 40
A setup utility automatically launches the first time that you access the switch and guides you through the basic configuration. For instructions on how to configure the switch and check module connectivity, see the appropriate Cisco Nexus 9000 Series Configuration Guides. Cisco Nexus 9364C-H1 ACI-Mode Switch Hardware Installation Guide...
As shown in the figure, each APIC is connected to one or two leaf switches and each leaf switch should be connected to every spine switch in the same fabric. Cisco Nexus 9364C-H1 ACI-Mode Switch Hardware Installation Guide...
Cisco equipment. In situations where long parallel cable runs cannot be separated by at least 3.3 feet (1 meter), we recommend that you shield any potential noise sources by housing them in a grounded metallic conduit.
Connecting Leaf Switches to APICs Downlink one or two (recommended for redundancy) Cisco Nexus 9300 platform ACI-mode leaf switches to each Application Policy Infrastructure Controller (APIC) in your ACI fabric. The type of virtual interface card (VIC) installed on the APIC determines the types of interface cables that you use to connect the leaf switches to the APICs.
Page 44
Connect the other end of the interface cable to a downlink port on a leaf switch. • For a Cisco 10GBASE-LR or -SR transceiver and cable, insert the transceiver into a downlink optical port on a leaf switch before connecting the cable to the transceiver.
Connecting the Switch to the ACI Fabric Connecting Leaf Switches to Spine Switches • For Cisco SFP+ Active Optical Cables, insert the transceiver on the cable into a downlink optical port on a leaf switch. • For a 10GBASE-T copper cable, insert the RJ-45 connector on the cable into a downlink BASE-T port on a leaf switch.
If you do not connect it to a modem, make the connection either before powering up the switch or after completing the boot process for the switch. Before you begin The console device must support VT100 terminal emulations and asynchronous transmissions. Cisco Nexus 9364C-H1 ACI-Mode Switch Hardware Installation Guide...
DB-9 connector on the other end of the cable to the serial port on the console device. What to do next Perform the initial configuration for the switch (see the Cisco ACI Getting Started Guide). Setting Up an Optional Management Connection Optionally set up an out-of-band management connection for monitoring and troubleshooting purposes.
Page 48
Note When you need to remove a fiber-optic transceiver, first remove the fiber-optic cable from the transceiver before you remove the transceiver from the port. Cisco Nexus 9364C-H1 ACI-Mode Switch Hardware Installation Guide...
If you must replace the fan module during operations and the above conditions are not met, leave the fan module that you need to replace in the chassis to preserve the designed airflow until you have the required module. Cisco Nexus 9364C-H1 ACI-Mode Switch Hardware Installation Guide...
Page 50
Position the fan module in front of the open fan slot (be sure that the backside of the module with the electrical connectors is positioned to enter the slot first) and slide the module all the way into the chassis until its front side Cisco Nexus 9364C-H1 ACI-Mode Switch Hardware Installation Guide...
If the STS LED does not turn on, slide the module out of the chassis, and visually check the electrical connectors on the back side of the chassis for damage. If damaged, contact Cisco Technical Assistance for help. If undamaged, repeat the previous step to reinstall the module.
To disconnect the power supply from its power cables, shut off the power from the power source and disconnect the connector for the power cables. Procedure Step 1 Turn off the circuit breaker for the power feed to the power supply that you are replacing. Cisco Nexus 9364C-H1 ACI-Mode Switch Hardware Installation Guide...
Verify that the LEDs turn off on the power supply that you are removing. Step 2 Remove the power cable from the power supply by pressing the latch on the Cisco-supplied power cord to allow removal from the power supply.
Insert the power supply cord Anderson SAF-D-Grid connector into the power supply inlet. Ensure the connector is locked. Gently tug on the cord near the connector to ensure the locking tab is engaged. Cisco Nexus 9364C-H1 ACI-Mode Switch Hardware Installation Guide...
Turn on the circuit breaker for the DC power source connected to the power supply. Step 4 Verify that the power supply is operational by making sure that the power supply LED is green. Cisco Nexus 9364C-H1 ACI-Mode Switch Hardware Installation Guide...
5. If the module has a bale-clasp latch, close it to lock the SFP/SFP+ module in place. 6. Remove the SFP and SFP+ dust plugs and save. 7. Connect the SFP and SFP+ cables. Cisco Nexus 9364C-H1 ACI-Mode Switch Hardware Installation Guide...
This icon is a hot surface warning. To avoid personal injury, do not touch without proper protection. Caution The transceiver module is a static-sensitive device. Always use an ESD wrist strap or similar individual grounding device when handling transceiver modules or coming into contact with system modules. Cisco Nexus 9364C-H1 ACI-Mode Switch Hardware Installation Guide...
Page 58
Align the transceiver module in front of the module’s transceiver socket opening and carefully slide the transceiver into the socket until the transceiver contacts the socket electrical connector. Figure 2: Installing the QSFP Transceiver Module Cisco Nexus 9364C-H1 ACI-Mode Switch Hardware Installation Guide...
Procedures for Fiber-Optic Connections document. Procedure Step 1 Remove the dust plugs from the optical network interface cable MPO connectors and from the transceiver module optical bores. Save the dust plugs for future use. Cisco Nexus 9364C-H1 ACI-Mode Switch Hardware Installation Guide...
Grasp the pull-tab and gently pull to release the transceiver from the socket. Figure 5: Removing the QSFP Transceiver Module Step 4 Slide the transceiver out of the socket. Step 5 Place the transceiver module into an antistatic bag. Cisco Nexus 9364C-H1 ACI-Mode Switch Hardware Installation Guide...
English universal hole spacing per section 1 of ANSI/EIA-310-D-1992). For more information, see Requirements Specific to Perforated Cabinets, on page The spacing between the posts of the rack must be (EIA-310-D-1992 19-inch rack compatible) wide enough to accommodate the width of the chassis. Cisco Nexus 9364C-H1 ACI-Mode Switch Hardware Installation Guide...
• The roof should be perforated with at least a 20 percent open area. • The cabinet floor should be open or perforated to enhance cooling. The Cisco R Series rack conforms to these requirements. Cable Management Guidelines To help with cable management, allow additional space in the rack above and below the chassis to make it easier to route all of the fiber optic or copper cables through the rack.
605 W 1100 W 4248.116 BTUs per hour Power Specifications Power specifications include the specifications for each type of power supply module. 1400-W AC Power Supply Specifications Property Specification Power 1400 W Cisco Nexus 9364C-H1 ACI-Mode Switch Hardware Installation Guide...
Redundancy Modes RoHS Compliance Hot Swappable 2000-W DC Power Supply Specifications These specifications apply to the NXA-PDC-2KW power supplies. Property Specification Power 2000 W Input Voltage Range Nominal: -48 to -60 VDC Frequency Cisco Nexus 9364C-H1 ACI-Mode Switch Hardware Installation Guide...
Power Cord Jumper, C13-C14 Connectors, 6.6 feet (2.0 m) North America CAB-9K12A-NA 125 VAC, 13 A, NEMA 5-15 plug, 8.2 feet (2.5 m) North America CAB-AC-L620-C13 NEMA L6-20-C13, 6.6 feet (2.0 m) Cisco Nexus 9364C-H1 ACI-Mode Switch Hardware Installation Guide...
HVAC 2-foot (0.6 m) cable with Saf-D-Grid and RT connector 277V AC CAB-HVDC-3T-2M HVDC 6.6-foot (2.0 m) cable with Saf-D-Grid and three terminal connectors 300V AC / 400V DC (+200/-200 V DC) Cisco Nexus 9364C-H1 ACI-Mode Switch Hardware Installation Guide...
Safety • CAN/CSA-C22.2 No. 60950-1 Second Edition • CAN/CSA-C22.2 No. 62368-1-19 Third Edition • ANSI/UL 60950-1 Second edition • IEC 62368-1 • EN 62368-1 • AS/NZS 62368-1 • GB4943 • UL 62368-1 Cisco Nexus 9364C-H1 ACI-Mode Switch Hardware Installation Guide...
Page 69
• CNS13438 Class A EMC: Immunity • EN55024 • CISPR24 • EN300386 • KN 61000-4 series RoHS The product is RoH-6 compliant with exceptions for leaded-ball grid-array (BGA) balls and lead press-fit connectors. Cisco Nexus 9364C-H1 ACI-Mode Switch Hardware Installation Guide...
Page 70
System Specifications System Specifications Cisco Nexus 9364C-H1 ACI-Mode Switch Hardware Installation Guide...
Amber Port admin state is 'Disabled, or the SFP is absent, or both. Port admin state is 'Enabled' and SFP is present, but interface is not connected. Cisco Nexus 9364C-H1 ACI-Mode Switch Hardware Installation Guide...
The power supply LEDs are located on the right portion of the power supply. Combinations of states indicated by the OK and Fault LEDs signify the status for the module as shown in this table. Cisco Nexus 9364C-H1 ACI-Mode Switch Hardware Installation Guide...
Page 73
Power supply is installed without a connection to a power source. (10 seconds) then amber Amber Power supply failure—possibly one of these conditions: • Over voltage • Over current • Over temperature • Power supply fan failure Cisco Nexus 9364C-H1 ACI-Mode Switch Hardware Installation Guide...
Not applicable Hazardous substances list for customers in China The table lists and illustrates the console cable (CAB-CONSOLE-RJ45) that can be ordered. Illustration Description Quantity Console cable with DB-9F and RJ-45F connectors Cisco Nexus 9364C-H1 ACI-Mode Switch Hardware Installation Guide...
Your completion of each task ensures a successful switch installation. Planning Activity Verification Time and Date Space evaluation: Space and layout Floor covering Impact and vibration Lighting Physical access Maintenance access Environmental evaluation: Ambient temperature Humidity Altitude Atmospheric contamination Airflow Cisco Nexus 9364C-H1 ACI-Mode Switch Hardware Installation Guide...
Interface equipment (transceivers) EMI evaluation: Distance limitations for signaling Site wiring RFI levels Contact and Site Information Use the worksheet to record contact and site information for the installation. Contact person Contact phone Cisco Nexus 9364C-H1 ACI-Mode Switch Hardware Installation Guide...
Hostname Domain name IP broadcast address Gateway/router address DNS address Use the worksheet to record information about the modules in the switch. Module Slot Module Type Module Serial Number Notes QSFP/QSFP-DD Tranceiver Cisco Nexus 9364C-H1 ACI-Mode Switch Hardware Installation Guide...
Page 80
Site Preparation and Maintenance Records Site Preparation and Maintenance Records Module Slot Module Type Module Serial Number Notes SFP/SFP+ Tranceiver Cisco Nexus 9364C-H1 ACI-Mode Switch Hardware Installation Guide...
Need help?
Do you have a question about the Nexus 9364C-H1 and is the answer not in the manual?
Questions and answers