Vents-us Airvents CFP Series User Manual

Air handling unit

Advertisement

Quick Links

USER'S MANUAL
Airvents CFP
Air handling unit

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Airvents CFP Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Vents-us Airvents CFP Series

  • Page 1 USER’S MANUAL Airvents CFP Air handling unit...
  • Page 2: Table Of Contents

    DO NOT PUT ANY FOREIGN OBJECTS ON THE POWER CABLE. DO NOT USE DAMAGED EQUIPMENT OR CABLES WHEN CONNECTING THE UNIT TO POWER MAINS. DO NOT TOUCH THE UNIT CONTROLS WITH WET HANDS. DO NOT CARRY OUT THE INSTALLATION AND MAINTENANCE OPERATIONS WITH WET HANDS. www.vents-us.com...
  • Page 3 UNAUTHORIZED ACCESS BY UNATTENDED CHILDREN. READ THE USER’S MANUAL BEFORE INSTALLING THE UNIT. INSTALLATION WORK AND ELECTRICAL WIRING MUST BE DONE BY QUALIFIED PERSON(S). WHEN CUTTING OR DRILLING INTO WALL OR CEILING, DO NOT DAMAGE ELECTRICAL WIRING AND OTHER HIDDEN UTILITIES. www.vents-us.com...
  • Page 4 PROMINENT WARNING DEVICE, SUCH AS A TAG, TO THE SERVICE PANEL. FOR GENERAL VENTILATING USE ONLY. DO NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS AND VAPORS. THE PRODUCT MUST BE DISPOSED SEPARATELY AT THE END OF ITS SERVICE LIFE. DO NOT DISPOSE THE UNIT AS UNSORTED DOMESTIC WASTE. www.vents-us.com...
  • Page 5: Purpose

    DELIVERY SET Name Number Unit 1 pc. User's manual 1 pc. Technical data sheet 1 pc. Automation wiring 1 pc. Control panel - according to the kit ordered 1 pc. User's manual for automation 1 pc. Packing box 1 pc. www.vents-us.com...
  • Page 6: Designation Key

    Airvents CFP DESIGNATION KEY www.vents-us.com...
  • Page 7: Technical Data

    The unit design is constantly being improved, thus some models may be slightly different from those described in this manual. UNIT OVERALL DIMENSIONS Ø D ød Model AV01 CFP 500(700) 11.7 59.1 63.0 43.3 48.4 9.88 0.63 ød Model AV01 CFP 1200 15.0 70.9 56.7 61.8 19.7 11.8 0.63 www.vents-us.com...
  • Page 8 23.6 13.8 0.63 AV03 CFP 3500 24.8 26.3 74.0 77.2 59.1 62.1 23.6 13.8 0.63 Model AV07 CFP 5000(6000) 39.4 74.8 33.7 46.7 33.7 31.5 19.7 The full technical data list is stated in the supplied technical data sheet. www.vents-us.com...
  • Page 9: Unit Design

    1: filter access panels (located at the bottom of the unit) 2: fan access panel (located at the bottom of the unit) 3: panel to access the heat exchanger and bypass damper (located at the bottom of the unit) 4: drain pipe The panels are secured with screws. www.vents-us.com...
  • Page 10 4: panel to access the filter (located on the service side) 5: filter access panel (located at the bottom of the unit) 6: fan access panel (located at the bottom of the unit) 7: drain pipe Panels 1-6 are fixed with screws. Panels 5 are secured with wing screws. www.vents-us.com...
  • Page 11 1, 2, 5 - filter access panel 3, 4, 8, 10 - fan access panel 6, 9 - panel to access the heat exchanger and bypass damper 7 - access panel to the filter and control unit 11 - drain pipe www.vents-us.com...
  • Page 12: Installation And Set-Up

    Supply air Supply air Exhaust air Intake air Intake air Extract air Extract air CFP 1500/2500/3500/5000/6000 Left-sided modification (top view) Right-sided modification (top view) Supply air Exhaust air Exhaust air Supply air Intake air Intake air Extract air Extract air www.vents-us.com...
  • Page 13 The fasteners for the unit installation are not included in the delivery set and must be purchased separately. Recommended installation diagram min 3° 1: threaded stud 2: nut 3: washer 4: vibration absorbing rubber 5: nut and counter nut www.vents-us.com...
  • Page 14 If the trap is equipped with a one-way valve, the height can be reduced, but this depends on the technical data of the trap. It is recommended to choose the height similarly to the trap without a one-way valve. The figure below illustrates a schematic example of a trap with a one-way valve. www.vents-us.com...
  • Page 15 The condensate drainage system should not be directly connected to the common sewage system to avoid polluting the air with bacteria and odors. To prevent the water from freezing over in winter, the pipeline laid outdoors or in unheated rooms must be equipped with heat insulation and pre-heating. www.vents-us.com...
  • Page 16: Connection To Power Mains

    It is not a malfunction. Clean the unit to troubleshoot unpleasant odours. The filters are accessible through the side service panels. Remove the service panels. CFP 1500/2500/3500/5000/6000 Remove the two butterfly bolts that fix the retaining Remove the filter elements. clamp. www.vents-us.com...
  • Page 17: Storage And Transportation Regulations

    The unit can be transported only in the working position. • Avoid sharp blows, scratches, or rough handling during loading and unloading. • Prior to the initial power-up after transportation at sub-zero temperatures, allow the unit to warm up at operation temperatures for at least 3-4 hours. www.vents-us.com...
  • Page 18: Manufacturer's Warranty

    If proof of sales date is absent, warranty period is calculated from the production date. The unit can be exchanged at the following address: Vents-US 400 Murray Road, Cincinnati, OH 45217, USA Tel: 1-888-640-0925, 513-583-5786, Fax: 513-268-4597 E-mail: support@ventsus.com...
  • Page 19: Certificate Of Acceptance

    The unit has been installed in accordance with the provisions of all the applicable local and national construction, electrical and technical codes and standards. The unit operates normally as intended by the manufacturer. Signature: WARRANTY CARD Unit Type Air handling unit Model Serial Number Manufacture Date Purchase Date Warranty Period Seller Seller’s Stamp www.vents-us.com...
  • Page 20 VUSA192-1EN-02...

This manual is also suitable for:

Airvents av01 cfp 500Airvents av01 cfp 700Airvents av01 cfp 1200Airvents av02 cfp 1500Airvents av02 cfp 2500Airvents av03 cfp 3500 ... Show all

Table of Contents