RF-TI1354P1 CC1354P1 SimpleLink High- Performance Sub-1G + 2.4 G Multi-band Module With Integrated Power Amplifier Version 1.0 Shenzhen RF-star Technology Co., Ltd. Oct. 18 , 2024 All rights reserved. Those responsible for unauthorized reproduction will be prosecuted.
The part numbers are of the form of RF-TI1354P1 where the fields are defined as follows: 1352 RF-STAR Module Version The First Version Company Name Chip Manufacturer Chipset TI CC1354P10 Figure 2. Part Number Conventions of RF-TI1354P1 Shenzhen RF-star Technology Co., Ltd. Page 3 of 22...
PA and non-PA RF output to realize the control of the transmission power range. Table 3. RF Control Truth Table Power DIO29 (Output) DIO30 (Output) +5 dBm ~ + 20 dBm (PA) < 5 dBm Shenzhen RF-star Technology Co., Ltd. Page 10 of 22...
The inverted-F antenna position on PCB is free-space electromagnetic radiation. The location and layout of the antenna are key factors to increase the data rate and transmission range. Therefore, the layout of the module antenna location and routing is recommended as follows: Shenzhen RF-star Technology Co., Ltd. Page 12 of 22...
1. A Π-type matching circuit is reserved for the antenna, and 50 Ω impedance control is performed on the RF traces. The traces are as short as possible, and 135° or arc traces are used as much as possible. No vias are used to Shenzhen RF-star Technology Co., Ltd. Page 13 of 22...
Page 15
Example: FR4 is a double-layer board with a thickness of 1.0 mm. Through calculation, the width of the trace is 0.8254 mm, and the spacing between traces and copper is 0.22 mm. Figure 11. SI9000 Impedance Calculation Diagram Shenzhen RF-star Technology Co., Ltd. Page 14 of 22...
1. It is recommended to offer the module a DC stabilized power supply, a tiny power supply ripple coefficient, and reliable ground. Please pay attention to the correct connection between the positive and negative poles of the power Shenzhen RF-star Technology Co., Ltd. Page 15 of 22...
4. The incorrect power register set or the high data rate in the open air may shorten the communication distance. The higher the data rate, the closer the distance. Shenzhen RF-star Technology Co., Ltd. Page 16 of 22...
3. If the extension wire or feeder wire is of poor quality or too long, the bit error rate will be high. 4.7 Electrostatics Discharge Warnings The module will be damaged by the discharge of static. RF-star suggests that all modules should follow the 3 precautions below: 1.
Page 19
Max. 6 ℃/s Time from 25 ℃ to Peak Temperature (t Max. 6 minutes Max. 8 minutes Time of Soldering Zone (t 20±10 s 20±10 s Figure 14. Recommended Reflow for Lead-Free Solder Shenzhen RF-star Technology Co., Ltd. Page 18 of 22...
Page 20
The default package method is . If you need the modules to be shipped by tape & reel, pls contact us in advance. Figure 15. Default Package by Tray Shenzhen RF-star Technology Co., Ltd. Page 19 of 22...
1. The document will be optimized and updated from time to time. Before using this document, please make sure it is the latest version. 2. To obtain the latest document, please download it from the official website: www.rfstariot.com and www.szrfstar.com. Shenzhen RF-star Technology Co., Ltd. Page 21 of 22...
Page 23
RF-TI1354P1 www.rfstariot.com V1.0 - Oct., 2024 7 Contact Us SHENZHEN RF-STAR TECHNOLOGY CO., LTD. Shenzhen HQ: Add.: Room A503, Podium Building No. 12, Shenzhen Bay Science and Technology Ecological Park, Nanshan District, Shenzhen, Guangdong, China, 518063 Tel.: 86-755-8632 9829 Chengdu Branch: Add.: N2-1604, Global Center, North No.
Need help?
Do you have a question about the SimpleLink RF-TI1354P1 and is the answer not in the manual?
Questions and answers