Votronic VAC 1215 F 3A II Installation And Operating Manual
Votronic VAC 1215 F 3A II Installation And Operating Manual

Votronic VAC 1215 F 3A II Installation And Operating Manual

Automatic charger

Advertisement

Installation and Operating Manual
Automatic Charger VAC 1215 F 3A II
Automatic Charger VAC 1230 F 3A II
Automatic Charger VAC 2416 F 3A II
Fully-automatic built-in chargers in protection class II (mains connection 2-core, without protective
conductor). DIN 14679: 2008-03 Fire Protection for fire-fighting and special purpose vehicles.
Please read these installation and operating instructions in full,
in particular page 2 "Safety guidelines and intended use", before you start connecting and
commissioning the device.
ATTENTION: The values being indicated in parentheses ( ) apply to 24 V operation.
VOTRONIC chargers of series "VAC F" distinguish by their compact design, low weight (high-frequency switching power
supply, Switch Mode Technology), as well as full charging capacity - even in the event of large fluctuations in the power
supply (undervoltage/overvoltage, sine wave form, frequency).
The intelligent microprocessor charging control with charging programs "IU1oU2oU3" (constant current - constant voltage)
and dynamic charging time calculation ensures automatic, quick and gentle full charging, as well as subsequent 100 %
trickle charge of the connected batteries from any charging state. At the same time, simultaneous supply of 12 V (24 V)
consumer loads, which are connected in parallel, is ensured or charging of very large batteries (depending on case of
application).
Battery Ports and Charging Programs:
Main charging port battery I (master), depending on the type of battery, 5 adjustable charging programs (see table 1):
a) "DIN AGM":
Closed, gas-tight AGM/fleece batteries VRLA (lead-fleece technology) "14.8 V"
b) "DIN Gel":
Closed, gas-tight gel/dryfit batteries VRLA (determined electrolyte)
c) "DIN VL":
Closed acid/lead-acid batteries with water consumption according to DIN EN 50342-1 "very low"
d) "DIN L":
Closed acid/lead-acid batteries with water consumption according to DIN EN 50342-1 "low"
and closed AGM/fleece batteries with indication of the charging voltage "14.4 V"
e) "Start":
Closed acid/lead-acid batteries with standard water consumption
Charging Port Battery II, adjustable charging programs depending on the type of battery (see table 2):
a) "II = I":
Charging programs as battery I with parallel charging by integrated charging current distributor
b) "II < I":
Designed for charging of starter batteries (max. charging current also for the starter battery)
Control Output "+86" (Engine Immobilizer)
12 V (24 V) signalling port for power supply indicator or vehicle engine immobilizer by external relay.
Voltage is supplied, as soon as the charger is connected to the mains, also during stand by.
Further Characteristics of the Unit:
The charging voltage is free from peaks and is controlled in such a way, that overcharging of the batteries is excluded.
Fully Automatic Continuous Operation: The charger may be connected continuously to the battery, thus keeping the
full charge. Battery discharge in case of power failure is avoided (separation by safety relay).
Battery regeneration in case of extended standstill periods: twice a week to avoid harmful acid accumulation.
Parallel and Floating Operation: In case of simultaneous consumption, the battery will either continue to be charged
or maintained via trickle charging. Calculation and control of the adaptation of the charging times is effected
automatically by the charger.
Unattended Charging: Multiple protection against overload, overheating, overvoltage, undervoltage, short circuit,
reverse battery, incorrect behaviour and back discharge of the battery by electronically controlled gradual reduction
down to complete separation of charger and battery by integrated safety relays.
Charging Capacity 12 V / 15 A
Charging Capacity 12 V / 30 A
Charging Capacity 24 V / 16 A
No. 0471
No. 0477
No. 0495

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VAC 1215 F 3A II and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Votronic VAC 1215 F 3A II

  • Page 1 ATTENTION: The values being indicated in parentheses ( ) apply to 24 V operation. VOTRONIC chargers of series "VAC F" distinguish by their compact design, low weight (high-frequency switching power supply, Switch Mode Technology), as well as full charging capacity - even in the event of large fluctuations in the power supply (undervoltage/overvoltage, sine wave form, frequency).
  • Page 2: Safety Regulations

    No liability is accepted for any resulting damage. The exclusion of liability also extends to any services provided by third parties that were not commissioned by us in writing. Services exclusively provided by VOTRONIC Elektronik-Systeme GmbH, Lauterbach.
  • Page 3 - 3 - Technical Data: VAC 1215 F 3A II VAC 1230 F 3A II VAC 2416 F 3A II Rated operating voltage (full charging power) 230 V, 45...65 Hz 230 V, 45...65 Hz 230 V, 45...65 Hz Operating voltage range 85...265 V...
  • Page 4: Installation Of The Unit

    - 4 - Installation of the Unit: The charger can be installed in the driver's compartment or team compartment, as close as possible to the main battery I (master) (short charging cables) at any location being clean and being protected from humidity and dust on an even and hard mounting surface.
  • Page 5: Connection Plan

    Note: If the unit is used with only 1 battery 12 V, use the charging port I (master). Table 1: Recommended Cross-sections and Lengths (one-way) for Charging Cables Unit and Battery I and II: Cable Cross-sections VAC 1215 F 3A II VAC 1230 F 3A II 2.5 mm 0.6 …...
  • Page 6 - 6 - Connection Plan 24 V: Note: If the unit is used with only 1 battery 24 V, use the charging port I (master). Table 1: Recommended Cross-sections and Lengths (one-way) for Charging Cables Unit and Battery I and II: Cable Cross-sections VAC 2416 F 3A II 2.5 mm...
  • Page 7 - 7 - Option: 2. Main Charging Port "Battery II": Set the charging port to full charging current. Use and setting of the charging program according to table 2. Option: Control Output +86: The output can be used as signalling port for a vehicle engine immobilizer (preventing an engine start, if the power supply of the vehicle is still inserted), see connection plan.
  • Page 8: Mains Connection

    - 8 - Mains Connection: The charger is designed as built-in charger for the driver's compartment or team compartment of the vehicle. It is executed in protection class II (no protective conductor). Thus, operation of the unit is allowed for mains sockets, which had been mounted according to the local regulations.
  • Page 9 - 9 - Mains Voltage Supply of the Unit via a Plug-in Device with Single Installation in Protection Class II according to DIN 14679: Legend Protection Area Cable H07RN-F 2x2.5 mm Unit Connection acc. to DIN EN 60309-1 PE Connection (connection to the vehicle is not admissible) PELV Protective Extra Low Voltage...
  • Page 10: Unit Settings

    - 10 - Unit Settings: How to Set the Type (Design, Technology) of Main Battery "I": 5 Charging programs for the different battery types are stored in the unit. They can be selected by means of the 3 micro slide switches “1-2-3” at the unit front. See connection plan: The control levers of the slide switches are shown in white.
  • Page 11 - 11 - DIN VL 14.8 V U1=14.80 V ! U2=13.50 V U3=13.20 V 4-6 h 24 h Continuous Battery Regeneration: 2 x week 1 h "VL": Charging program according to DIN 14679 for acid/lead-acid batteries, lead-acid VL: Adapted to closed lead batteries with water consumption "VL=Very Low"...
  • Page 12 - 12 - Table 2: Setting of the Charging Program for Battery II Type (Design) Use a small screw-driver to carefully move the slide switch No. 4 behind the front panel of the unit to the desired " position for battery II. Also refer to connection plan (factory adjustment II <...
  • Page 13: Pilot Lamps

    - 13 - Pilot Lamps: "Battery Full" (Battery (batteries) fully charged, green): • If it is on: Battery (batteries) had (have) been charged to 100 %, trickle charge U2 and storage charge U3, finished. • If it is flashing: Main charging process is effected in the charging phase U1, indication of charging state of approx.
  • Page 14 - 14 - Operating Instructions: • Indicator Residual Charging Time: A flashing pilot lamp "Battery Full" allows conclusions concerning the progress of the charging phase U1 (full charging). Directly after the charging phase I (approx. 75-80 % charge) the indicator will only be flashing momentarily.
  • Page 15 - 15 - Chronological Sequence Charging Process Main Port Battery I (Master): A new, complete main charging cycle will be executed: • After a power failure (mains plug withdrawn or power failure). • After unit switch in position "Stand By". •...
  • Page 16 Recycling: At the end of its useful life, you can send us this device for professional disposal. You can find more information about this on our website at www.votronic.de/recycling Delivery Scope: 1 Charger Temperature Sensor 825...

This manual is also suitable for:

Vac 1230 f 3a iiVac 2416 f 3a ii047104770495

Table of Contents