Download Print this page
Votronic StandBy-Charger Pro Installation And Operating Manual
Votronic StandBy-Charger Pro Installation And Operating Manual

Votronic StandBy-Charger Pro Installation And Operating Manual

Advertisement

Quick Links

Installation and Operating Manual
StandBy-Charger Pro
Device for recharging and trickle charge a battery from another battery.
Please read this operating and installation manual thoroughly prior to connection and start-up.
The VOTRONIC StandBy-Charger serves for recharging and trickle charge of the starter battery in vehicles with two battery
circuits. A possible connection can be made between the supply or body battery and the starter battery. Only the operation
with two same nominal battery voltages 12V / 12V is permitted. Mixed operation 12V and 24V is not allowed.
Only the operation with two equal rated battery voltages 12 V/12 V is permissible, mixed Operation 12 V
and 24 V is not allowed.
Device mounting
The StandBy-Charger Pro should be installed as close as possible to the battery to be charged and protected from moisture.
The StandBy-Charger Pro can be mounted at the external attachment points of the casing as shown in figure 2
(specifications in mm).
Input 12...15 V max. 12 A, Output 12,5...14,5 V max. 8 A
Figure 1: front view of StandBy-Charger Pro
Figure 2: dimensions of the attachment points of the casing
No. 3063

Advertisement

loading
Need help?

Need help?

Do you have a question about the StandBy-Charger Pro and is the answer not in the manual?

Questions and answers

Summary of Contents for Votronic StandBy-Charger Pro

  • Page 1 Device mounting The StandBy-Charger Pro should be installed as close as possible to the battery to be charged and protected from moisture. The StandBy-Charger Pro can be mounted at the external attachment points of the casing as shown in figure 2 (specifications in mm).
  • Page 2  To activate the StandBy-Charger Pro permanently, a jumper can be connected from IN+ to EN. Alternatively a switchable 12 V control signal can be applied to the EN terminal for turning the StandBy-Charger Pro on and off.  If the StandBy-Charger Pro should be deactivated while the output battery is being charged by the alternator, the D+ signal of the alternator can optionally be connected to the DIS terminal.
  • Page 3 Afterwards, connect the output battery to the device. If the StandBy-Charger Pro is activated via the terminal EN and is not switched off by the terminal DIS, the charging of the output battery starts automatically if required.
  • Page 4 - 4 - 1. Connect the battery and the enable signal “EN“ on the input side and set the shutdown threshold on the input side via the potentiometer U INLO Note: For commissioning, this must be >= the input battery voltage 2.
  • Page 5: Operation Indicators

    - 5 - 3. Connect the battery on the output side Operation indicators Note: For a correct operation indicator it is necessary to connect a battery to the OUT+ and OUT- terminals. LED 1 (green) LED 2 (yellow) State Standby / input voltage too low / set output voltage is lower than the voltage of the output-side connected battery...
  • Page 6: Technical Data

    - 6 - Technical Data Input „IN“ Nominal operating voltage DC 12 V Input voltage range 12…15 V Input shoutdown threshold range 12…14 V Current consumption in standby <1 mA Max. current consumption 12 A Terminal cable cross-sections (flexible without ferrule) 1…4 mm Output „OUT“...
  • Page 7 - 7 - Notes:...
  • Page 8 No liability is accepted for any resulting damage. The exclusion of liability also extends to any service work carried out by third parties and not commissioned by us in writing. Exclusively VOTRONIC Elektronik-Systeme GmbH provides services.