JA-153M, JA-153M-AN, JA-153M-GR Wireless magnetic detector
with recognition of external magnetic fields
Type: 5MAG2203SA
The product is a component of the JABLOTRON system. It is used for
the detection of opening doors, windows, etc. The device has a selectable
reaction (pulse or status). It should be installed by a trained technician
with a valid certificate issued by an authorized distributor.
This device is compatible only with JA-102K, JA-103K and
JA-107K control panel units.
Installation
During installation., if possible, avoid placing the device directly onto
metal surfaces which may negatively impact the device's ability to
communicate with the system.
Two types of magnets are supplied with the detector. A ferrite magnet
in a plastic housing (A) and a ring magnet (B). The correct location of both
types of magnets is shown in the illustration. The distances for
activation/deactivation of the detector with the ferrite magnet (for non-
magnetic mounting surface) are shown in the table. For other magnet
types or opposite polarity, these values may vary.
Fig: 1 – Locking screw hole, 2 – Housing tab, 3 – Indication LED,
4 – Battery, 5 – Serial number, 6 – Housing tamper contact
1.
Open the device cover by pressing the housing tab
(2).
2. Mount the device's backplate onto a chosen
location.
3. Screw the selected magnet onto a moving part,
e.g. a door leaf. The bottom edge of the ferrite
magnet plastic must coincide with the bottom edge
of the detector housing. It is recommended to use
a special non-magnetic screw (included in the
package) to attach the ring magnet.
4.
Proceed according to the control panel installation manual:
Basic procedure:
a. In the F-Link software, select the required position in
the Devices window and launch the enrolment mode by
clicking on the Enrol option.
b. Insert the battery (mind the correct polarity). The enrolment
signal is transmitted when the battery is inserted into
the detector.
5. Close the detector cover.
Notes:
The detector can also be enroled into the system by entering its
serial number (5) into the F-Link software (1400-00-0000-0001).
You can find the sticker with the serial number/bar code, located
on the battery holder.
6. In order to comply with norms, the front cover must be secured with
the supplied locking screw (1).
7. Configure the detector by following the Internal settings chapter in
this manual.
Detector communication in the system
The detector uses bi-directional asynchronous communication which
allows for changing the internal settings remotely and battery capacity
saving simultaneously.
After enrolment to the system, the detector operates in an accelerated
mode, until the service mode is exited (but no longer than 24 h). In this
mode, the detector checks every 90s whether system is still in service
mode or if new settings should be taken over.
In service mode, the detector communicates once every 19 minutes or
with each activation. Therefore, when switching from operational mode to
service mode, it can take up to 19 minutes for the detector to recognize
control panel status or internal settings change, this is indicated by the
red font on the internal settings button. This period can be reduced by
activating the detector or its tamper sensor.
JA-153M, JA-153M-AN, JA-153M-GR
Please note:
It is not necessary to wait 90 s (or 19 min) until the detector confirms
delivery of the new setting, when changes are applied. System
remembers the requested change and forwards the new settings to the
detector during the next period of regular communication.
Internal settings of the detector
The settings are configured by the F-Link software - Devices tab. Use
the Internal settings option on the detector position. A dialog will appear
in which the detector functions can be set:
LED indication: On/Off
Pulse mode: Only activations are transmitted to the system
Foreign magnetic field detection: When switched on, the detector will
analyze its surrounding magnetic field and in case of its disturbance (e.g.
by a foreign magnet) the detector will declare an Input Activation and
a Fault. The function brings higher protection of the object.
Note: for the correct function of the foreign magnetic field detection it is
necessary to calibrate the detector to the working value of the magnetic
field.
Warning: When the foreign magnet detection function is switched on,
the window or door can only be opened in the direction in which the
magnet movement has been calibrated. Otherwise, the detector will
declare a Fault simultaneously with the Activation. Therefore, this function
cannot be used for windows or doors that are opened in multiple ways
(opening, tilting).
Calibration: button to start the calibration process.
To start the calibration from the periphery, the system must be in
Service mode, then Activate tamper contact (open the plastic cover) and
within 5 seconds deactivate the tamper contact (close the plastic cover).
This procedure will enable calibration directly from the periphery –
indication as described below from point 3 (inclusive). The Yellow LED
will not be lit when calibration is started from the detector (it is only lit if
the peripheral has an open internal setting in the F-Link). Calibration can
be terminated by activating the tamper contact (open the plastic cover).
Calibration procedure in F-Link + optical indication:
1.
LED Off = the device waiting for connection. To continue, activate
and deactivate the magnet (open and close the window/door).
2.
Yellow LED on = detector has established a connection. Start
calibration to continue.
3.
Activate the detector in order to confirm presence of the magnet.
The LED indicates in yellow with the red LED regularly flashing
twice.
4.
Please return the magnetic detector into its un-activated state.
Yellow LED on + rapid flashing of red LED = magnetic detector
calibration takes place for approx. 4 s.
5.
Yellow LED on + slow flashing red LED = detector is ready to
continue calibration. To continue, activate the detector by
opening and closing the window/door. Confirmation of the
detector calibration will be indicated by the red LED lighting up for
approx. 1 s. Then the red LED will go out and the setting status will
change to complete, the yellow LED remains lit.
Tables of distance values for activation and deactivation of the
detector when using the supplied ferrite magnet (values may vary
when used with other permanent magnets).
Axis
Activation distance (mm)
Deactivation distance (mm)
Table 1: Distances for activation/deactivation of a detector installed on
non-magnetic surface.
Axis
Activation distance (mm)
Deactivation distance (mm)
Table 2: Distances for activation/deactivation of a detector installed on
magnetic surface.
Battery replacement
The system sends a report automatically when the battery is low.
Remember to switch the system to Service mode before changing
the batteries (otherwise a tamper alarm will be triggered). Check the right
function of the detector after battery replacement.
1 / 2
X
Y
Z
11
10
23
8
8
18
X
Y
Z
9
10
25
7
8
20
MSA51302

Advertisement

loading
Need help?

Need help?

Do you have a question about the JA-153M and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for jablotron JA-153M

  • Page 1 JA-153M, JA-153M-AN, JA-153M-GR Wireless magnetic detector with recognition of external magnetic fields Type: 5MAG2203SA The product is a component of the JABLOTRON system. It is used for Please note: the detection of opening doors, windows, etc. The device has a selectable It is not necessary to wait 90 s (or 19 min) until the detector confirms reaction (pulse or status).
  • Page 2 ERC/REC 70-03 Recommended screw ø 3.5 x 40 mm (countersunk head) JABLOTRON ALARMS a.s. hereby declares that the 5MAG2203SA product is in a compliance with the relevant Union harmonization legislation: Directives No.: 2014/53/EU, 2014/35/EU, 2014/30/EU, 2011/65/EU if it is used as intended. The original of the conformity assessment can be found at www.jablotron.com - Section...

This manual is also suitable for:

Ja-153m-anJa-153m-gr