CleanCraft SCWP 7014A Instruction Manual

Clear water immersion pump

Advertisement

Quick Links

Instruction Manual
Clear water immersion pump
SCWP 7014A
SDWP 7014A
SDWP 7014A

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SCWP 7014A and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for CleanCraft SCWP 7014A

  • Page 1 Instruction Manual Clear water immersion pump SCWP 7014A SDWP 7014A SDWP 7014A...
  • Page 2: Table Of Contents

    15 Spare parts............17 15.1 Ordering spare parts........17 The contents of these operating instructions are the sole 15.2 Spare parts drawing Model SCWP 7014A property of the company Stürmer.Passing on as well as and SDWP 7014A........... 18 copying of this document, the use and distribution of its 16 Electrical circuit diagram........19...
  • Page 3: Introduction

    1.3 Limitation of liability You have made a good choice by purchasing the All information and notes in these operating instructions CLEANCRAFT water pump. were summarised while taking applicable standards and rules, the state-of-the-art technology and our long-term Read the operating manual thoroughly before com- knowledge and experiences into consideration.
  • Page 4: Obligations Of The Operating Company

    Safety - The operating company must be informed about the applying industrial safety regulations and further an- CAUTION! alyse hazards resulting from the special working This combination of symbol and signal words indi- conditions at the place of use of the Clear water im- cates a potentially dangerous situation which may mersion pump.
  • Page 5: Personal Protective Equipment

    Safety Only persons reliable working procedures can be ex- pected from, are allowed to perform all works. Persons Protective gloves the responsiveness of which is affected by e. g. drugs, The protective gloves serve to protect the hands alcohol or medication, are not allowed to work with the against sharp components as well as against fric- machine.
  • Page 6 Safety - Make sure that the electrical plug connections are installed in an area that cannot be flooded. DANGER! - The pump must not be used when there are people The pumped liquid may be hot and under high pres- in the water.
  • Page 7: Safety Labels On The Water Pump

    35 °C. If safety labels on the machine are damaged or missing, The SCWP 7014A water pump can be used for clean to this can cause errors, personal injury and material dam- slightly contaminated water with a maximum particle size age.
  • Page 8: Technical Data

    The removal of danger spots, disturbances and unevenness at the time of trans- port by other employees leads to considerable dangers. Careful planning of internal transport is therefore essen- Fig. 3: Type plate SCWP 7014A tial. Clear water immersion pump | Version 1.05...
  • Page 9: Packaging

    (at least 5°C). DANGER! Fig. 4: Description SCWP 7014A Risk of frost: If the electric pump has to be stored 1 Power cable below 0 °C, make sure that there is no liquid left in the pump.
  • Page 10: Installation And Assembly

    Installation and assembly Installation and assembly Hose diameter 38 mm (1 1/2") Step 1: Cut off the top two connection nipples at b (Fig.7) 9.1 Assembly of the pressure line The following hose diameters can be connected to the pump: Hose diameter 13 mm (1/2"), 15 mm (5/8"), 19 mm (3/4").
  • Page 11: Notes On Installation

    Installation and assembly 9.2 Notes on installation 9.3 Electrical connection The device has a power supply cable with a mains plug: DANGER! - The mains connection cable and plug may only be When installing the unit, make sure that the motor is replaced by qualified personnel to avoid hazards.
  • Page 12: Positioning The Pump

    Commissioning 9.4 Positioning the pump Use protective clothes! Move the electric pump only by using the carrying handle. The pump can be lifted with a rope and lowered into the water. The rope must be attached to the carrying handle. Wear safety boots! Wear safety glasses! DANGER!
  • Page 13: Switching On The Water Pump

    Operation 11.1 Switching on the water pump ATTENTION! DANGER! The device must be correctly installed before use. It must also be checked that the filter elements are cor- rectly mounted and efficient. Make sure that the pump is properly placed and ready for operation.
  • Page 14: Manual Operation

    Care, maintenance and repair 11.1.2 Manual operation If the pump is operated in manual mode, it is possible to switch the pump in continuous operation. Step 1: Connect all hoses to the water pump, fill the pump with clean water. Step 2: Push the button 5 (Fig.11) to Manual.
  • Page 15: Care By Cleaning

    Care, maintenance and repair Step 1: Unscrew the Phillips screws (7,Fig.6) and re- 12.1 Care by cleaning move the base plate (8,Fig.6) from the pump. The water pump must always be kept in a clean condi- tion. Step 2: Unscrew the Phillips screws (9,Fig.6) and re- move the suction plate (10,Fig.6) from the pump.
  • Page 16: Troubleshooting

    Troubleshooting 13 Troubleshooting NOTE! DANGER! If you cannot solve the problems with your water If one of the following errors occurs, stop working pump yourself, please contact your nearest CLEAN- with the water pump immediately. CRAFT dealer. Please write down the following infor- Before you start troubleshooting, switch off the water mation about the water pump or the operating instruc- pump and unplug the power cord.
  • Page 17: Waste Disposal Of Electric Equipment

    The bearing for the Clear water immersion pump nies.Disposal notes for used lubricants are available SCWP 7014A must be ordered. The bearing has the from the manufacturer of the lubricants. If necessary, re- number 65 in the spare parts drawing 1.
  • Page 18: Spare Parts Drawing Model Scwp 7014A And Sdwp 7014A

    The following drawing should help you to identify necessary spare parts in case of service. To order, send a copy of the parts drawing with the marked components to your authorized dealer. Fig. 14: Spare parts drawing Model SCWP 7014A and SDWP 7014A Clear water immersion pump | Version 1.05...
  • Page 19: Electrical Circuit Diagram

    Electrical circuit diagram 16 Electrical circuit diagram 16.1 Electrical circuit diagram Model SCWP 7014A and SDWP 7014A Fig. 15: Electrical circuit diagram Model SCWP 7014A and SDWP 7014A Clear water immersion pump | Version 1.05...
  • Page 20: Ec-Declaration Of Conformity

    D-96103 Hallstadt hereby declares that the following product Product group: Cleancraft® Reinigungstechnik Machine type: Clear water immersion pump Designation of the Clear water immersion pump*: Item number*: SCWP 7014A 7520110 SDWP 7014A 7520210 Serial number*: ____________________ Year of manufacture*: 20_________...
  • Page 21: Notes

    Notes 18 Notes Clear water immersion pump | Version 1.05...