1.3 Limitation of liability You have made a good choice by purchasing the All information and notes in these operating instructions CLEANCRAFT Water pump. were summarised while taking applicable standards and rules, the state-of-the-art technology and our long- Read the operating manual thoroughly before commis- term knowledge and experiences into consideration.
Safety protection regulations applying for the area of applica- tion of the Water pump must be met. The following ap- WARNING! plies in particular: This combination of symbol and signal words indi- cates a potentially dangerous situation which may - The operating company must be informed about the lead to death or severe injury if not avoided.
Safety Only persons reliable working procedures can be ex- pected from, are allowed to perform all works. Persons Protective gloves the responsiveness of which is affected by e. g. drugs, alcohol or medication, are not allowed to work with the The protective gloves serve to protect the hands against sharp components as well as against fric- machine.
ATTENTION! Intended use Do not pump salt water with the pump! The submersible pumps SCWP 7514, SCWP 10013 and ATTENTION! the submersible pressure pump SPWP 1107 are suita- ble for pumping clean water. After the device has been tipped over, it is recom- mended to set it up again and then switch it off.
3.1 Improper use WARNING! Fig. 2: Type plate SCWP 7514 Danger in case of misuse! Misuse of the special Water pump can lead to dan- gerous situations. - Only operate the special Water pump in the power range listed in the technical data.
Technical Data Technical Data Model SCWP 7514 SCWP 10013 SDWP 7514 SDWP 10020 SPWP 1107 Length [mm] 183,5 Width / Depth [mm] Phi 163 Height [mm] Weight (netto) [kg] Application area Under water Under water Under water Under water Under water Discharge head max.
(PS). Deliver these substances to a collection point for recyclable materials or to the waste disposal company which looks after your region. Fig. 3: Description SCWP 7514 6.4 Storage 1 Handle The Water pump should be stored in a dry, frost-free en- 2 Upper cover vironment.
1 Handle 6 Baseplate Operation 2 Upper cover 7 Cable hook The submersible pump series SCWP 7514, SDWP 7514, 3 Pump body 8 Power cable SCWP 10013, SDWP 10020 and SPWP 1107 are de- 4 Outflow connection 9 Float switch signed to pump impure, fiber-free water.
Page 11
Fig. 9: Correct lifting or mounting of a rope SCWP 7514 On certain models, there is an outlet on the contact sur- face between the pump body and the head cover. It is a...
Installation Reset to clear water mode: Step 1: Submerge the pump at an angle to avoid an air cushion at the bottom that would prevent it from Step 1: Turn the electric pump so that the floor is facing being sucked in. you.
Start-up - Never lift or carry the pump by the water drain Start-up hose or the power cord. - Protect the power plug and power cord from heat, oil and sharp edges. WARNING! - The connection and protection of electrical parts Danger to life! must be made according to local regulations.
Operation ATTENTION! ATTENTION! The replacement of a defective power cord must be To avoid fire hazards, keep the pump at least 1 carried out by the technical service or by qualified meter away from building walls and other equip- personnel. ment during operation.
Care, maintenance and repair 11 Care, maintenance and repair NOTE! When commissioning for the first time, it is essential ATTENTION! to make sure that the pump housing is completely deaerated, even with self-priming pumps - that is, Before maintenance work, the pump must be discon- filled with water.
CLEANCRAFT dealer. Please write down the follow- ing information from the water pump or the operating 11.4 Decommissioning instructions in advance to help you with your problem in the best possible way.
Page 17
Disturbances, possible causes and measures Troubleshooting table of the water pump models SCWP 7514 and SDWP 7514: Malfunction Possible cause Measurement The pump works, but A. The suction grille is clogged. A. Clean the filter. does not deliver water. B. The impeller is clogged.
No. and year of manufacture on the type plate fixed to the Water pump. Example The stator housing for the Water pump SCWP 7514 must be ordered. The stator housing has the number 38 in the spare parts drawing 1.
In case of service, the following drawing shall help to identify the necessary spare parts. If necessary, send a copy of the parts drawing with the marked components to your authorised dealer. Fig. 13: Spare parts drawing 1 Model SCWP 7514 Water Pumps | Version 1.02...
Page 20
Spare parts Fig. 14: Spare parts drawing 2 Model SCWP 10013 Water Pumps | Version 1.02...
Page 21
Spare parts Fig. 15: Spare parts drawing 3 Model SDWP 7514 Water Pumps | Version 1.02...
Page 22
Spare parts Fig. 16: Spare parts drawing 4 Model SDWP 10020 Water Pumps | Version 1.02...
Page 23
Spare parts Fig. 17: Spare parts drawing 5 Model SPWP 1107 Water Pumps | Version 1.02...
Need help?
Do you have a question about the SCWP 7514 and is the answer not in the manual?
Questions and answers