Advertisement

Quick Links

Instruction Manual
Deep well pump
DWP 1106 A
DWP 1106 A

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DWP 1106 A and is the answer not in the manual?

Questions and answers

Summary of Contents for CleanCraft DWP 1106 A

  • Page 1 Instruction Manual Deep well pump DWP 1106 A DWP 1106 A...
  • Page 2: Table Of Contents

    14 Spare Parts .......... 14 Germany. 14.1 Ordering spare parts........14 14.2 Spare parts drawing DWP 1106 A....15 The contents of these operating instructions are the sole Property of the company Stürmer Maschinen GmbH. 15 Circuit diagram DWP 1106 A ....16 Passing on and reproduction of this document, exploita- 16 EC-Declaration of Conformity....
  • Page 3: Introduction

    1.3 Limitation of liability You have made a good choice by purchasing the All information and notes in these operating instructions CLEANCRAFT Water pump. were summarised while taking applicable standards and rules, the state-of-the-art technology and our long-term Read the operating manual thoroughly before com- knowledge and experiences into consideration.
  • Page 4: Obligations Of The Operating Company

    Safety - The operating company must be informed about the applying industrial safety regulations and CAUTION! further analyse hazards resulting from the special This combination of symbol and signal words indi- working conditions at the place of use of the Water cates a potentially dangerous situation which may pump.
  • Page 5: Requirements To Staff

    Safety 2.3 Requirements to staff 2.4 Personal protective equipment The personal protective equipment serves to protect per- The different tasks described in this manual represent sons against impairments of safety and health while wor- different requirements to the qualification of the persons king.
  • Page 6: Safety Markings On The Water Pump

    Safety -Wear appropriate protective clothing and goggles when installing the water pump. DANGER! - Before each use make sure that no parts of the water pump are damaged. Damaged parts must be replaced Check that the supply voltage of the water pump cor- immediately to avoid sources of danger.
  • Page 7: Intended Use

    Intended use Intended use Type plate The DWP 1106 A deep well pump is intended for private use in the house and hobby garden. It is intended for drawing water from wells and cisterns and for operating irrigation equipment. The height of the pump is 90 cm. It can therefore be used in shallow water depths.
  • Page 8: Transport, Packaging, Storage

    Fig. 3: Description of the DWP 1106 A chopped up and given to the recycling collection. 1 Pump outlet / pressure line connection...
  • Page 9: Electrical Connection

    Commissioning Commissioning All connecting lines must be absolutely tight, as leaking lines can impair the performance of the pump and cause considerable damage. It is therefore essential to seal the WARNING! threaded parts of the lines with each other and the Danger to life! connection to the pump with Teflon tape.
  • Page 10: Connection Of The Pressure Line

    Operation 9.1 Connection of the pressure line 10 Operation DANGER! Danger to life from electric shock! DANGER! There is a danger to life when in contact with live The discharge line must be installed so that it cannot components. Switched-on electrical components can exert mechanical forces or distortions on the pump.
  • Page 11: Setting The Water Requirement

    Care, maintenance and repair Step 3: Start the pump and open the discharge valve un- til you hear a very distinct noise from the DANGER! pump. This noise is called cavitation and sounds as if there is gravel inside the pump. The pump pumps and switches off automatically as soon as no more water is taken.
  • Page 12: Maintenance And Repair

    Disposal, recycling of used devices Clean all plastic parts and painted surfaces with a soft, Maintenance and repair work may only be carried out by damp cloth and a little neutral cleaner. qualified personnel. If necessary, clean the suction slots of the suction foot If the water pump does not work properly, contact a de- with clear water.
  • Page 13: Disposal Via Municipal Collection Points

    CLEANCRAFT dealer. Please write down the follow- ing information from the water pump or the operating instructions in advance to help you with your problem in the best possible way.
  • Page 14: Spare Parts

    Spare Parts 14 Spare Parts Example The engine for the Deep well pump DWP 1106 A must DANGER! be ordered. The engine has the number 49 in the spare Danger of injury by the use of parts drawing 1. wrong spare parts!
  • Page 15: Spare Parts Drawing Dwp 1106 A

    The following drawing should help you to identify necessary spare parts in case of service. If necessary, send a copy of the parts drawing with the marked components to your authorized dealer. Fig. 5: Spare parts drawing DWP 1106 A DWP - 1106 A | Version 1.03...
  • Page 16: Circuit Diagram Dwp 1106 A

    Circuit diagram DWP 1106 A 15 Circuit diagram DWP 1106 A Fig. 6: Circuit diagram DWP 1106 A DWP - 1106 A | Version 1.03...
  • Page 17: Ec-Declaration Of Conformity

    16 EC-Declaration of Conformity Manufacturer / distributor: Stürmer Maschinen GmbH Dr.-Robert-Pfleger-Str. 26 D-96103 Hallstadt hereby declares that the following product Product Category: Cleancraft® Cleaning Technology Machine type: Deep well pump Designation of the device: DWP 1106A Item number: 7523105 Serial number*:...
  • Page 18 www.cleancraft.de...