Page 1
SPLIT-TYPE AIR CONDITIONER INDOOR UNIT OUTDOOR UNIT Basic Code: AR24HVSSAWKNED AR24HVSSAWKXED Model Code: AR24JVSSAWKNED AR24JVSSAWKXED AIR CONDITIONER CONTENTS 2. Product Specifications 3. Alignment and Adjustments 4. Disassembly and Reassembly AR24JVSSAWKNED 5. Control Exploded Views and Part list 6. Electrical Parts List 7.
Do not place a cloth or other materials over it. Remove the batteries if you don't use the remote control for a long time. (If applicable) Use the remote control within 7 meters from the indoor unit. (If applicable) Samsung Electronics...
Never store or load the air conditioner upside down or sideways to prevent the damage to the compressor. Young children or infirm persons should be always supervised when they use the air conditioner. Max current is measured according to IEC standard for safety. Current is measured according to ISO standard for energy efficiency. Samsung Electronics...
Smart Installation Smart Check - Don’t worry about the trouble-shooting in your home Triple Protector Plus - Use longer without damage in unsuitable conditions Easy Installation - Secure the easy Installation of Indoor unit and pipe connection Easy Filter Samsung Electronics...
Page 7
Propeller Blow er Type Resin/steel/AC Resin/steel/AC motor Rated Output(W) Heat Exchanger 2Row 16Step 1Row 75Step Refrigerant Control Unit Freezer Oil Capacity Refrigerant to Change(R410A) 1150 Proterction Device(OLP) None Operation condition range Cooling 16~46 ℃ Samsung E l ectroni c s...
Page 8
Outdoor Unit Indoor Unit (kg) Net Weight Outdoor Unit 47.5 (kg) Indoor Unit 1123*354*384 (mm*mm*mm) Outer Dimension Outdoor Unit 1023*911*413 (mm*mm*mm) Indoor Unit (dB) Noise Outdoor Unit (dB) Air Purifying System Filter FULL HDFILTER Samsung E l ectroni c s...
2-4 Accessory and Option Specifications o i t Installation Plate DB90-07731A ASSY WIRELESS REMOCON DB93-15169D Indoor unit case 4301-000121 Batteries for Remote controller DB68-05069A User’s & Installation Manual CAP-SCREW DB67-01404B Samsung Electronics...
Because the teat mode operate the cool mode by force not related to the set temperature / indoor ● temperature, check whether each subordinate is operated normally or not after completing installation Note and must turn off the power of the air conditioner. Samsung Electronics...
DC-Link Voltage Sensor Error AC Input Voltage Sensor Error AC Input I_Limit Trip Error Gas Leak Error EEV or Valve Close error-Self diagnosis Test Operation at Cooling Mode Test Operation at Heating Mode LED ON, LED OFF, LED BLINKING Samsung Electronics...
1. Tack out the batteries of remote control. 2. Press the temperature button simultaneously and insert the battery again. 3. Make sure the remote control display shown as Step 2 Enter the Options Setup mode and select your options asscording to the following procedure. Samsung Electronics...
Page 14
When pressing the operation ON/OFF key with the direction of remote control for unit, the sound ’’Ding’’ or ’’ and the OPERATION ICON( ) lamp of the display is flickering at the same time, then the input of option is completed. (If the deriving sound isn’t heard, try again pressing the ON/OFF button.) Samsung Electronics...
Page 15
Every time you push the button, the display panel reads . . . repeatedly. Push the Mode button to set the display panerl to 1. Every time you push the button, the display panel reads . . . repeatedly. Samsung Electronics...
Page 16
Model SEG 1-6 SEG 7-12 SEG 13-18 SEG 19-24 SEG 25-30 SEG 31-36 SEG 37-42 SEG 43-48 SEG 49-54 SEG 55-60 SEG 61-66 SEG 67-72 AR24JVSSAWK/ED 010045 10628C 274600 37F644 020000 100000 200000 300000 034500 104300 200000 300001...
Page 17
4) Execute the Inverter Download program 5) Select COM Port and connect 4) CLICK 6) Open the file (*.src) 7) Click the Start button and reset the power Reset power Waiting down load Download 6) CLICK 5) CLICK 7) CLICK Samsung Electronics...
Page 18
PIN# 1:RXD, 2:TXD, 9:GND, 10:VCC 4) Execute the Inverter Download program 5) Select COM Port and connect 4) CLICK 6) Open the file(*.src) 7) Click the Start button Waiting down load Download 6) CLICK 5) CLICK 7) CLICK 3-10 Samsung Electronics...
2) Detach FILTER PRE from the PANEL FRONT. 3) Cover Panel is assembled on bottom of indoor unit as shown in the figure. Remove the Cap Screw as shown on the right side and then remove the screw and separate the Cover Panel. Samsung Electronics...
Page 20
5) Separate the hook after pushing both end of Cover Panel as shown in the figure. (Watch out for the damage of the hook) 6) Raise front part upward obliquely as shown in the figure and then remove the hooks. Samsung Electronics...
Page 21
Assembly of Cover Panel after service end. - Reassembly is in the reverse order of the removal. - Piping and drain hose must be careful not to damage and Progress must be done with both hands. Hook (Side) Hook (Center) Screw Cap Screw Samsung Electronics...
Page 22
4 HOOK Structures. When separate the hook : Use the (-) screw Driver. (-)Screw Driver Insert the hook and then pull the hook as shown on the right side. (Watch out for the damage of the hook) Samsung Electronics...
Page 23
Parts Procedure Remark 9) Remove the Panel Frame from the Main Frame as shown on the right side. 10) Remove the WIFI KIT connector. WIFI KIT connector is located of Panel Front. (For model with WIFI KIT) Samsung Electronics...
Page 24
7) Loosen the POWER wire and T/B fuse wire Caution: When you separate the connector, pull pressing the locking button. 8) Loosen the step motor wire,sensor wire and display wire connector Caution: When you separate the connector, pull pressing the locking button. Samsung Electronics...
Page 25
9) Take o the CASE-CONTROL from the main frame after loosen the remaining connector. Caution: When you separate the connector, pull pressing the locking button. TRAY DRAIN 1) To detach TRAY-DRAIN from the main frame, pull the bottom of the TRAY-DRAIN towards you. Samsung Electronics...
Page 26
2) Unfasten the screw at the left side. (use + Screw Driver) 3) Unfasten the screw at the right side. (use + Screw Driver) 4) To detach Evaporator from the main frame, pull the bottom of the Evaporator towards you. Samsung Electronics...
Page 27
Remark FAN MOTOR 1) Unfasten the screw. (use + Screw Driver) & CROSS FAN 2) Detach the FAN Motor case. 3) Unfasten the screw a little. (use + Screw Driver) 4) Pull the CROSS-FAN to the left side. Samsung Electronics...
4-2. Outdoor Unit Parts Remark Produre Common Wor 1) Loosen each screws and detach the Cabi Top Cover. 2) Loosen screws of the Cabi Front and detach it. Samsung Electronics 4-17...
Page 29
Parts Procedure Remark 3) Loosen the 4 screws and detach the condbar. 4) Loosen fixing screws from the Cabi Front Lh and detach it. 5) Loosen fixing screws from the Cabi Side Rh and detach it. 4-18 Samsung Electronics...
Page 30
2) Detach the Fan Propeller. 3) Loosen 4 fixing screws to detach the Motor. (Use Monkey Spanner.) 4) Disconnect the wire between Ass’y Control Out and Motor. 5) Loosen 2 fixing bolts and detach the Bracket Motor.(Use Monkey Spanner Samsung Electronics 4-19...
Page 31
3) Detach several connectors from the PCB of Ass’y Control Out. Heat Exchanger 1) Release the refrigerant at first. 2) Loosen fixing screw on both sides. 3) Disassemble the pipes in both inlet and outlet with welding torch. 4) Detach the Heat Exchanger. 4-20 Samsung Electronics...
Page 32
Parts Procedure Remark Compressor 1) Loosen the xing nut and detach the Compressor Lead Wire. (Use Monkey Spanner.) 2) Loosen the bolts at the bottom of Compressor like the picture on the right side. (Use Monkey Spanner.) Samsung Electronics 4-21...
Page 33
5-2 ASSY KIT ----- DB92-03468C 95-05163A ASSY CASE CONTROL IN DB90-08726B 03467C ASSY CONNECTOR WIRE-MOTOR DB93-15322A ASSY CONNECTOR WIRE-DISPLAY DB93-15359A Samsung E l ectroni c s...
#5 : FAN RPM #6 : FAN FEEDBACK CN002 - PO WER-L CN003 - EARTH CN150 - SMPS AC CN402 - C OMP #1 : W #1 : L #1 : E ARTH #1,#3 : A C220~240V #3 : U Samsung Electr onics...
If not, there exists a possibility of fire which can be caused by electric heat in the connecting part. : Good Bad : Ring terminal is connected reversely Bad : Not clamped Screw Bad : In the gap between Ring terminal & Screw Bad : Unused Ring Terminal Samsung Electronics...
9-1-1 Indoor Unit The design and shape are subject to change according to the model. Main parts Air intake (up and down) (left and right) Display Power indicator Timer/Auto clean indicator Power button/ Virus Doctor indicator Remote controller receiver Samsung Electronics...
Move through the Timer, Options or Settings menu to make a selection Options or Settings button again, then the most recently selected item will blink and you may simply cancel it by pressing the SET button while selected item is blinking. Samsung Electronics...
HEAT mode, and indoor fan and out- Indoor fan and outdoor fan stop operation door fan do not operate intermittently for within 20% intermittently in a HEAT mode. of the total heater operation. 10-1 Samsung Electronics...
Is the power is normal? Exchange the PBA of no power unit (check the LED Lamp) Exchange the indoor unit PBA. Is the communication error occurred again? Terminate the service. Exchange the outdoor unit PBA. 10-2 Samsung Electronics...
Page 62
10-2-2 Indoor temperature sensor Error Indoor display Sam sung Electronics 10-3...
Page 63
Is the connection of power cable supply power and measure the voltage of #3-#4 and communication cable normal? and #5-#6 in the connector Exchange the indoor PBA Below 0.5V or Over 4.5V? Micom error or connector check Exchange the indoor PBA 10-4 Samsung Electronics...
Page 64
Is the connected louver wire? Do operation start when swing button of Normal remote control unit pushed? Is the voltage changeable at the Exchange the PBA pin#2~#5 of CN61,CN62, CN63 (louver connector)? Up/Down louver motor is faulty. Samsung Electronics 10-5...
Check the fuse open or not? (F701 F702) Exchange the Main PBA Restart after power off. Is the power normal? Check the power source. Check the sub PBA/display PBA Press the power button on the sub PBA? Exchange the Main PBA Samsung Electronics 10-29...
Is the connection of power cable supply power and measure the voltage of "B"in the connector and communication cable normal? Exchange the Outdoor PBA Below 0.5Vdc or Over 4.5Vdc? Micom error or connector check Exchange the Outdoor PBA Samsung Electronics 10-7...
Is the connection of power cable power and measure the voltage of "B"in the connector and communication cable normal? Exchange the Outdoor PBA Below 0.5Vdc or Over 4.5Vdc? Micom error or connector check Exchange the Outdoor PBA 10-8 Samsung Electronics...
Is the connection of power cable power and measure the voltage of "B"in the connector and communication cable normal? Exchange the Outdoor PBA Below 0.5Vdc or Over 4.5Vdc? Micom error or connector check Exchange the Outdoor PBA Samsung Electronics 10-9...
Restart after power off Is the discharge over temperature Terminate the service sensor error appeared again? Download the EEPROM data Is the discharge over temperature Terminate the service sensor error appeared again? Exchange the Outdoor PBA Exchanged the Compressor 10-10 Samsung Electronics...
Page 70
Is the voltage of "A" #3-#5 Exchange the Outdoor PBA and #3-#6 with in 1Vdc~15Vdc during the operation? PBA problem or Motor problem Change the PBA first and check the operation Exchange the Fan motor Samsung Electronics 10-11...
Is the connection of compressor wire is normal? Connect the comp wire normally Download the EEPROM data Is the restart error occurred again? Terminate the service Is the compressor body and interphase Exchange the Outdoor PBA resistance insulated? Exchange the compressor 10-12 Samsung Electronics...
Is the connection of compressor wire is normal? Connect the comp wire normally (PBA and Compressor) Is the restart error occurred again? Terminate the service Is the compressor body and Exchange the Outdoor PBA interphase resistance insulated? Exchange the compressor Samsung Electronics 10-13...
Connect the comp wire normally Is the O.C error occurred again? Terminate the service Is the condition of indoor/outdoor temperature Restart after returning to the normal load normal load? Is the O.C error Terminate the service occurred again? 10-14 Samsung Electronics...
Page 74
Is the position of Correct the sensor position or temperature sensor and sensing exchange the sensor value normal? Is the compressor body and interphase resistance Exchange the Outdoor PBA insulated? Exchange the compressor Samsung Electronics 10-15...
Page 75
("A") is normal in operation mode? Check the power input Normal range(280Vdc~320Vdc) Is the DC_link Exchange the Outdoor PBA sensing voltage("B") is normal in operation mode? Normal range (0.2Vdc~4.8Vdc) Exchange the Outdoor PBA Is the reactor insulation damaged? Exchange the Reactor 10-16 Samsung Electronics...
Restart after power off. Start the operation (cooling or heating mode) Is the DC_link sensing voltage("B") is normal in operation mode? Exchange the Outdoor PBA Normal range (0.2Vdc~4.8Vdc) Exchange the Outdoor PBA Is the reactor insulation damaged? Exchange the Reactor Samsung Electronics 10-17...
Page 77
Check the input power in the powercord. Normal range(180Vac ~ 270Vac) Restart after power off. Start the operation (cooling or heating mode) Is the DC_link voltage ("A") is normal in operation mode? Check the input power Normal range(280Vdc~320Vdc) 10-18 Samsung Electronics...
Page 78
Is the DC_link sensing Exchange the Outdoor PBA voltage("D")is normal in operation mode? Normal range (0.2Vdc~4.0Vdc) Exchange the Outdoor PBA Is the reactor insulation damaged? Exchange the Reactor Samsung Electronics 10-19...
Page 79
Is the position of Correct the sensor position or temperature sensor and the sensing exchange the sensor value normal? Is the connection cable for the compressor and power Correct the cable connection terminal normal? Exchange the Outdoor PBA 10-20 Samsung Electronics...
IC451 DB92-02867A R063,R064,R065 R408,R409,R410 IC451 Restart after power off. Is the PFC shunt and IPM Exchange the Outdoor PBA shunt resistance value correct? Is the current sensor error appeared again? Terminate the service Exchange the Outdoor PBA Samsung Electronics 10-21...
4) Is the cover assembly in control-box normal? 2. Troubleshooting procedure Restart after power off. Are there screws in PBA-heatsink? Fastening the screw (4 screws) Check the fan connection Is the fan operation normal? Change the Fan motor Exchange the Outdoor PBA 10-22 Samsung Electronics...
Page 82
Terminate the service Is the Comp Vlimit error occurred again? Is the condition of Restart after returning to the indoor/outdoor temperature normal load? normal load Is the O.C error Terminate the occurred again? service Samsung Electronics 10-23...
Page 83
Is the position of Correct the sensor position or temperature sensor and sensing exchange the sensor value normal? Is the compressor body and interphase resistance Exchange the Outdoor PBA insulated? Exchange the compressor 10-24 Samsung Electronics...
2. Troubleshooting procedure MODEL "A" DB92-02865A CN571 DB92-03444B CNP551 power off and download EEPROM data (or. Insert the service EEPROM IC) Restart after power off Terminate the service Is the error appeared again? Exchange the Outdoor PBA Samsung Electronics 10-25...
* Heating mode * * Cooling mode * Is the outdoor temperature over 40 or Is the outdoor temperature under -7 under -30 ? The temperature condition is too poor to operate. Wait until temperature is changed 10-26 Samsung Electronics...
Terminate the service. Check the EEV valve operation. Is the EEV valve connection normal? Connect the EEV valve. Is the EEV valve is operation? Change the EEV valve. Check the sound of EEV valve after power on. Samsung Electronics 10-27...
Page 87
Check the pipe crack. Is the pressure of refrigerant normal? Fill up the refrigerant. Exchange the Indoor PBA Exchange the Outdoor PBA 10-28 Samsung Electronics...
Check the fuse open or not? (F701 F702) Exchange the Main PBA Restart after power off. Is the power normal? Check the power source. Check the sub PBA/display PBA Press the power button on the sub PBA? Exchange the Main PBA Samsung Electronics 10-29...
Page 89
"G" Main 15V : 14Vdc ~ 15Vdc Is the SMPS is normal? Exchange the SMPS PBA "G" Main 12V : 11Vdc ~ 13Vdc Is the SMPS is normal? Exchange the SMPS PBA "H" Main 5V : 4.5Vdc ~ 5.5Vdc Exchange the PBA Samsung Electronics 10-31...
Page 90
1) Check the power condition at customer's house (Is there any power noise?) 2) Have been there power failure? 2. Troubleshooting procedure Restart after power off Is AC line zero cross signal error appeared again? Terminate the service Exchange the Outdoor PBA 10-32 Samsung Electronics...
Page 91
Reset the option code again at indoor unit Terminate the service Is the capacity miss match error appeared again? Download the EEPROM data Is the capacity miss match error appeared again? Terminate the service Exchange the Outdoor PBA Exchange the Indoor PBA Samsung Electronics 10-33...
Page 92
2) Check the battery in remote control 3) All the lights out and check again : Change electronic typed to a fluorescent light 4) Put the set in operation and check the voltage of display PBA 5) Replace the display PBA 10-34 Samsung Electronics...
Page 93
Is the EEV valve is operation? Change the EEV valve. Check the sound of EEV valve after power on. Check the pipe crack. Is the pressure of refrigerant normal? Fill up the refrigerant. Exchange the Indoor PBA Exchange the Outdoor PBA Samsung Electronics 10-35...
Page 94
- Discharge temperature and the indoor [Execute the troubleshooting] temperature measurements confirm Check the refrigerant leaks. that the difference is more than 10 . Check the PCB Relay. - Fill up perfectly refrigerant after re-vacuum. Execute the related trouble- shooting. 10-36 Samsung Electronics...
2) The fan motor of the indoor unit . Fan motor connector(CNP72) is faulty. 1. Fan speed(high) doesn't run. 2. Continuous Operation 3) The power voltage between terminal #1-#3 of the . PBA is faulty. connector(CNP72) is 0V. Samsung Electronics 10-37...
Page 96
- When Thermal Fuse is opened, Main PBA (DC12V) is turned off and the indoor unit does not operate. (There is no problem with Main PBA in this case) - In the above case, the change of all-in-one Terminal Block will make Main PBA operate again. Circuit Block Measurement method of fair/defective thermal fuse 10-38 Samsung Electronics...
Download Comm. Main - Inv Sensor Control Inverter Main Current 4Way V/V Micom Micom Sensing Inverter Compressor Download ZCP OVP DC LINK Communi Comm. In - out cation Converter POWER Filter SMPS Reactor SMPS - PBA SMPS 11-2 Samsung Electronics...
11-2-1 Pre-inspection Notices 11-2-2 Inspection procedure 1. Check connector connection and peeling of PCB or bronze coating pattern when you think the PCB is broken 11-2-3 Indoor detailed inspection procedure Samsung Electronics 11-3...
1) Normal : RED on, GRN blink, YEL off 2) Abnormal . F1,F2 wire wrong wiring Check the LED lamp display - All off : check no power . Outdoor PBA is faulty - abnormal display : check error mode 11-4 Samsung Electronics...
It occurs when the drain pump is plugged out or it is out of order. Check the power of the drain pump and the position of the drain hose, and when the pump is faulty, contact the drain pump manufacturer. Samsung Electronics do not manufacture drain pumps. So, we are not able to correct the drain pump problems.
Page 104
Also, the remote con- troller may mot work under intensive light from a 3-wave length lamp or a neon sign due to the EMI. In this case, take the remote controller closer to the receiver. 12-3 Samsung Electronics...
Page 105
There is a cost table. But, our service engineer needs to visit to total up the cost correctly. When you move in, make sure to contact Samsung Electronics Service Center or Authorized Service Agent in advance to streamline the process.
Clean the Air filter with a vacuum cleaner or soft brush. If dust is too heavy, rinse it with running water. Insert the air filter back in its original position. Dry the Air filter in a ventilated area. it once a week. 12-5 Samsung Electronics...
Electric and earth work shall meet the "Electric Facility Technology Standard" and the "Internal Wire Regulation" of the Electric Business Laws. ■ Inspection & Trial Run Upon completion of the tests, you shall make a trial run while you explain the main functions of the air conditioner to finish the installation. 12-6 Samsung Electronics...
3 way valve. And mount the service port cap to 3 way valve. Valve stem Stem cap 7) Check for gas leakage. (gas) - At this time, especially check for gas leakage from the 3 way valve's stem nuts, and from the service port cap. (liquid) 12-7 Samsung Electronics...
7) Close the cap of each valve. Relocation of the air conditioner entering. At this time, cover the valve of the outdoor unit and the other pipe using a cap or vinyl plug to avoid foreign material entering. 12-8 Samsung Electronics...
12-7.ReferenceSheet IndexforModelName 10th 11th 12th 13th 14th Project Capacity Sell Feature Series Color Export Unit Item Reference 3TH 4TH Item ITEM Item Export 12Year INVERTER HP Export 13Year INVERTER CO Export 14Year Export 15Year Export 16Year Item2 9TH DIGIT Item1 Export 1st MODEL A Export The virus doctor (The India / Latin America A / PAC K besides) S Export...
Need help?
Do you have a question about the AR24HVSSAWKNED and is the answer not in the manual?
Questions and answers