Fire Safety
Fire Kits
For installations with a floor more than 4.5m above ground, a
compatible fire kit must be fitted. The kits listed below contain all
the extra parts and instructions required:
Order Code
KIT-PIV-SMOKE-200
Smoke Alarms
For installations with a floor more than 4.5m above ground, the unit
should be wired into a smoke alarm, in order to switch the unit off upon
the detection of smoke. A smoke alarm kit is available using order code
1ACSMOKEALARM-KIT. The unit can also be wired into an existing smoke
alarm (check compatibility with the smoke alarm manufacturer).
All wiring should be completed by a competent person.
To test the installation, press the TEST button on top of the smoke
alarm and keep it pressed until the PIV unit switches off (LEDs on the
board go out).
14
LV2-EVL & LV2-EVL-H
Description
PIV fire kit with 1x 200mm diffuser
SHOULD YOU ENCOUNTER ANY PROBLEMS